Advertisement

Quick Links

SILVERLINE FI
INSTALLATION AND USER MANUAL
of your heat pump
WWW.POOLEX.FR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SILVERLINE FI 150 and is the answer not in the manual?

Questions and answers

Summary of Contents for POOLEX SILVERLINE FI 150

  • Page 1 SILVERLINE FI INSTALLATION AND USER MANUAL of your heat pump WWW.POOLEX.FR...
  • Page 2 WARNING This heat pump contains a flammable refrigerant R32. Any intervention on the refrigerant circuit is prohibited without a valid authorization. Before working on the refrigerant circuit, the following precautions are necessary for safe work. 1. Work procedure The work must be carried out according to a controlled procedure, in order to minimize the risk of presence of flammable gases or vapors during the execution of the works.
  • Page 3 Our aim is to provide you with an exceptional high performance quality product. We have produced this manual with the utmost care so that you get maximum benefit from your Poolex heat pump. EN | 3...
  • Page 4: Please Read Carefully

    They must be given to the installer and retained by the user. If the manual is lost, please consult the website: www.poolex.fr The instructions and recommendations contained in this manual should be read carefully and understood since they provide valuable information concerning the heat pump’s safe handling and operation. Keep this manual in an accessible place for easy future reference.
  • Page 5: Table Of Contents

    CONTENTS 1. General 1. 1. General terms of delivery ............................6 1. 2. Safety instructions ..............................6 1. 3. Water treatment ..............................7 2. Description 2. 1. Package contents ..............................8 2. 2. General characteristics ............................8 2. 3. Technical specifications ............................9 2.
  • Page 6: General

    1. GENERAL 1. 1. General terms of delivery All equipment, even if shipped ‘free of carriage and packing’, is dispatched at the consignee’s own risk. The person responsible for receiving the equipment must carry out a visual inspection to identify any damage to the heat pump during transport (refrigerant system, body panels, electrical control box, frame).
  • Page 7: Water Treatment

    The low and high side test pressure must not exceed 42 bar. 1. 3. Water treatment Poolex heat pumps for swimming pools can be used with all types of water treatment systems. Nevertheless, it is essential that the treatment system (chlorine, pH, bromine and/or salt chlorinator metering pumps) is installed after the heat pump in the hydraulic circuit.
  • Page 8: Description

    Winter storage cover 홀 4 anti-vibration pads (fastenings not supplied) 2. 2. General characteristics A Poolex heat pump has the following features: ► CE certification and complies with the RoHS European directive. ► High performance with up to 80% energy savings compared to a conventional heating system.
  • Page 9: Technical Specifications

    2. DESCRIPTION 2. 3. Technical specifications Poolex Silverline FI Test conditions Heating power (kW) 6.8~1.94 9.2~2.23 11.3~2.28 14.5~2.25 19.2~2.59 Power in Silence mode (kW) 3.31~1.54 4.75~2.23 5.77~2.08 7.31~2.25 10.47~2.59 26°C Consumption (kW) 1.05~0.15 1.46~0.16 1.86~0.13 2.43~0.14 3.14~0.16 Water 26°C Consumption in Silence mode (kW) 0.36~0.12...
  • Page 10: Unit Dimensions

    2. DESCRIPTION 2. 4. Unit dimensions Dimensions en mm Silverline FI 70 / 90 / 120 1143 1107 10 | EN...
  • Page 11: Exploded View

    2. DESCRIPTION 2. 5. Exploded view Top panel Compressor Logic board box Front panel Back panel Fan blade Pressure gauge Fan motor Water Flow Switch Fan support Heat exchanger Electrical terminal block Right side panel Middle support gas pipe Electric transformer Electrical control box Electrical control box Electrical box cover...
  • Page 12: Installation

    3. INSTALLATION WARNING: Installation must be carried out by a qualified engineer. This section is provided for information purposes only and must be checked and adapted if necessary according to the actual installation conditions. 3. 1. Pre-requirements Equipment necessary for the installation of your heat pump: ◊...
  • Page 13: Installation Layout

    3. INSTALLATION 3. 3. Installation layout Automated treatment system Heat pump 4-way valve (salt chlorinator, metering pump) Valve 1 Valve 5 Valve 3 Valve 2 Water outlet Water inlet Elevating Valve 4 studs Filtration Condensation Circulating draining pump FROM THE POOL TOWARDS THE POOL Valves 1, 2 et 3 : Bypass valves Valves 4 et 5 : Regulating valves...
  • Page 14: Hydraulic Connection

    3. INSTALLATION WARNING: Installation must be carried out by a qualified engineer. This section is provided for information purposes only and must be checked and adapted if necessary according to the actual installation conditions. 3. 6. Hydraulic connection Open valve By-Pass assembly Half-open valve The heat pump must be connected to the pool by means of a By-Pass...
  • Page 15 3. INSTALLATION By-Pass assembly for one heat pump TO THE POOL Automated processing system POOL Filtration + Pump FROM THE POOL Half-open valve Open valve By-Pass assembly for more than one heat pump TO THE POOL Automated processing system POOL Filtration + Pump FROM THE POOL Half-open valve...
  • Page 16: Electrical Installation

    In places open to the public, it is mandatory to install an emergency stop button close to the heat pump. Protection Diameter Models Power supply Max. current (A) magneto-thermal of cable (curve D) Silverline FI 70 RO2V 3x2.5 mm² 16 A Silverline FI 90 RO2V 3x2.5 mm² 16 A Single-phase Silverline FI 120 RO2V 3x2.5 mm²...
  • Page 17: Electrical Connection

    3. INSTALLATION 3. 8. Electrical connection WARNING: The heat pump’s power supply MUST be disconnected before any operation. Please comply with the following instructions to electrically connect the heat pump. Step 1: Detach the electrical side panel with a screwdriver to access the electrical terminal block. Step 2: Insert the cable into the heat pump unit by passing it through the opening provided for that purpose.
  • Page 18: Use

    4. USE 4. 1. Wired remote control ROOM VALUE TEMP AUTO 4. 2. Control box displays Before starting, ensure that the filtration pump is working and that water is circulating through the heat pump. Prior to setting your required temperature, you must first select an operating mode for your heat pump: Cooling mode Speed compressor Full Inverter...
  • Page 19: Operating Mode Selector

    4. USE ROOM VALUE TEMP AUTO 4. 3. Operating mode selector Push on to change the operating mode. The different modes appear in the following order: Heating mode Full Inverter Cooling Mode Full Inverter Heating mode Boost Cooling mode Boost Heating mode Eco silence Cooling mode...
  • Page 20: Setting The Clock

    4. USE ROOM VALUE TEMP ROOM VALUE ROOM VALUE ROOM VALUE TEMP TEMP TEMP AUTO 4. 6. Setting the clock ROOM VALUE VALUE ROOM ROOM VALUE TEMP TEMP TEMP AUTO AUTO AUTO ROOM VALUE Step 1: Press 5s to enter current time setting. TEMP AUTO AUTO...
  • Page 21: Programming Start/Stop

    4. USE 4. 7. Programming Start/Stop ROOM VALUE TEMP ROOM VALUE ROOM VALUE ROOM VALUE This function is for programming the Start/Stop timing. You can programme up to 2 different Start/Stop timings. TEMP TEMP TEMP AUTO Setting is as follows: AUTO ROOM VALUE...
  • Page 22: System Parameter Query

    4. USE 4. 9. System parameter query WARNING: This operation is used to assist servicing and future repairs. The default settings should only be modified by an experienced professional person. ROOM VALUE TEMP WARNING: Any change to the reserved settings will automatically void the warranty. ROOM VALUE ROOM...
  • Page 23: Wifi

    The ‘Smart Life’ app and services are provided by Hangzhou Tuya Technology. Poolstar, owner and distributor of the Poolex brand, cannot be held responsible for the operation of the ‘Smart Life’ app. Poolstar has no visibility on your ‘Smart Life’ account.
  • Page 24 4. USE 4.11.2. Setting up the app WARNING : Before you begin, make sure you have downloaded the «Smart Life» app, connected to your local WiFi network, and that your heat pump is electrically powered and running. You’ll need to create a «Smart Life» account to control your heat pump remotely. If you already have a Smart Life account, please log in and go directly to step 3.
  • Page 25 4. USE Step 3: (Recommended) Add an object by clicking «...» and then «Add Object.» Enter its name («Pool» for example), then click «Done.» Step 4: Now add a device to your «Pool» Click «Add» or «+» and then «Large appliances...» followed by «Water heater.» At this point, leave your smartphone on the «Add»...
  • Page 26 WiFi access points). Note: The flashing stops when the box is connected to WiFi The pairing is successful, you can rename your Poolex heat pump then press «Done». Congratulations, your heat pump can now be controlled from your smartphone.
  • Page 27 4. USE 4.11.4. Controlling Interface Current pool temperature Temperature setpoint Current operating mode Switch the heat pump On/Off Change the temperature Change the operating mode Set the operating range Configure the operating ranges for the heat pump Step 1: Create a schedule, choose the time, day(s) of the week(s), and the action (turn on or off) and save. Step 2: To delete a time slot, press on it and hold.
  • Page 28: Operation

    5. OPERATION 5. 1. Operation Conditions of use For the heat pump to operate normally, the ambient air temperature must be between -7°C and 43°C. Recommendation prior to start-up Before activating the heat pump, please: 홀 Check that the unit is firmly secured and stable. 홀...
  • Page 29: Using The Pressure Gauge

    5. OPERATION 5. 3. Using the pressure gauge The gauge is for monitoring the pressure of the refrigerant contained in the heat pump. The values it indicates can vary considerably, depending on the climate, temperature and atmospheric pressure. When the heat pump is in operation The gauge’s needle indicates the refrigerant pressure.
  • Page 30: Maintenance And Servicing

    6. MAINTENANCE AND SERVICING 6. 1. Maintenance and servicing WARNING: Before undertaking maintenance work on the unit, ensure that you have disconnected the electrical power supply. Cleaning The heat pump’s casing must be cleaned with a damp cloth. The use of detergents or other household products could damage the surface of the casing and affect its properties.
  • Page 31: Repairs

    7. REPAIRS WARNING: Under normal conditions, a suitable heat pump can heat the water in a swimming pool by 1°C to 2°C per day. It is therefore quite normal to not feel any temperature difference in the system when the heat pump is working. A heated pool must be covered to avoid any loss of heat.
  • Page 32: List Of Faults

    7. REPAIRS 7. 2. List of faults Code Faults Possible cause Actions Check your water circuit operation and the Insufficient water in heat exchanger opening of the By-Pass valves Flow sensor malfunction Sensor disconnected or defective Reconnect or replace sensor Protection activated when the Antifreeze protection ambient temperature is too low and...
  • Page 33: Errors

    7. REPAIRS Code Faults Possible cause Actions Ambient temperature or water Make sure the unit is working in available temperature too high temp. range for ambient and water temp. Poor heat exchanger for evaporator Check if the evaporator is blocked and clean Outdoor coil temperature too Gas pipe blocked for cooling system Check if the gas pipe is blocked...
  • Page 34: Warranty

    The Poolstar Company guarantees the original owner against defective materials and faults in the manufacture of the Poolex Jetline Premium Inverter heat pump for a period of two (2) years. The compressor is guaranteed for a period of five (5) years.
  • Page 35: Annex

    9. ANNEX ROOM VALUE TEMP 9. 1. Parameter checking AUTO To enter the verification parameters, keep pressing press for 3 seconds. Code Description Note Air discharge temp. Air suction temp. Inlet water temp. Outlet water temp. Outdoor coil temp. Outdoor ambient temp. IPM temp.
  • Page 36 9. ANNEX ROOM VALUE TEMP AUTO 9. 2. System parameter query Keep pressing 3 s until you enter the settings Code Name Range Default 0: ON constantly Water pump working mode 1: OFF 60s after compressor off,Pump ON 5 min Per L1 min. Water pump working period In standby mode,water pump work 5 min per L1 min.
  • Page 37 9. ANNEX N° Description Range Default Remarks Reserve Reserve Reserve Reserve EEV Maximum opening 50~480 480P Adjustable EEV Minimum opening 50~300 Adjustable Reserve OF: OFF Forced recycle refrigerant Adjustable ON: ON Heating maximum setting temperature 35~60°C 40°C Adjustable Heating minimum setting temperature 15~25°C 15°C Adjustable...
  • Page 38: Wiring Diagrams

    9. ANNEX 9. 4. Wiring diagrams Water Flow Switch High Pressure Switch Short Circuit Connection Low Pressure Switch FCN1 T1(Red) Discharge temp.sensor T2(Yellow) Coil temp. sensor T3(Green) Ambient temp. sensor T4(White) Inlet water sensor Outlet Water sensor T5(Blue) T6(Black) Suction temp sensor CN17 4WAY Buttom Plate...
  • Page 39 EN | 39...
  • Page 40 SCAN FOR MORE INFO T E C H N I C A L A S S I S TA N C E www.assistance.poolstar.fr Poole x i s a brand of the group 04-2025 WWW.POOLEX.FR...

Table of Contents