EdilKamin KIRA2 H 18 UP Instructions For Installation, Use And Maintenance Manual
EdilKamin KIRA2 H 18 UP Instructions For Installation, Use And Maintenance Manual

EdilKamin KIRA2 H 18 UP Instructions For Installation, Use And Maintenance Manual

Pellet boiler stove

Advertisement

Quick Links

VYDA2 H 18 UP
VYDA2 H 22 UP
KIRA2 H 18 UP
KIRA2 H 22 UP
PELLET BOILER STOVE
For all updates visit www.edilkamin.com
EN
Installation, use and maintenance
page
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KIRA2 H 18 UP and is the answer not in the manual?

Questions and answers

Summary of Contents for EdilKamin KIRA2 H 18 UP

  • Page 1 VYDA2 H 18 UP VYDA2 H 22 UP KIRA2 H 18 UP KIRA2 H 22 UP PELLET BOILER STOVE For all updates visit www.edilkamin.com Installation, use and maintenance page...
  • Page 2 VYDA2 H 22 UP KIRA2 H 22 UP SERIAL NO.: Rating plate reference VYDA2 H 18 UP KIRA2 H 18 UP Dichiarazione di prestazione (DoP - EK n° 218) VYDA2 H 22 UP KIRA2 H 22 UP Dichiarazione di prestazione (DoP - EK n°...
  • Page 3: Meaning Of Symbols

    • the purchase receipt given to you by the retailer; www.edilkamin.com • the declaration of conformity (or the documents required in the country of installation) issued to you by Readers of this manual the installer.
  • Page 4 • use of fuel other than wood warranties, refer to the pellets. DO NOT BURN warranty certificate inside WASTE MATTER, PLASTIC the product: specifically, OTHER MATERIALS neither Edilkamin nor the THAN WOOD PELLETS retailer are liable for damage COMBUSTION resulting from incorrect CHAMBER.
  • Page 5 SAFETY INFORMATION • cleaning the smoke duct • use of the product as a with cleaning products. DO support ladder. NOT CLEAN THE PRODUCT NOT CLIMB ONTO THE WITH FLAMMABLE PRODUCT OR USE IT AS A PRODUCTS. Risk of fire or SUPPORT.
  • Page 6 DIMENSIONS VYDA2 H 18, UP VYDA2 H 22 UP (cm) Ø 8 Ø 5 smoke outlet combustion air 14 13 Hydraulic connections depend on the optional kits. You can find further information in the paragraph “water circuit installation” 61.5 USER/INSTALLER...
  • Page 7 DIMENSIONS KIRA H 18, KIRA H 22 (cm) Ø 8 Ø 5 smoke outlet combustion air 14 13 Hydraulic connections depend on the optional kits. You can find further information in the paragraph “water circuit installation” USER/INSTALLER...
  • Page 8: Technical Data

    NOTE: the smoke outlet diameter does not match the chimney system diameter, which must be sized accordingly. EDILKAMIN S.p.A. reserves the right to modify the product at its own discretion and without prior notice, with a view to improvements. USER/INSTALLER...
  • Page 9: Electrical Specifications

    TECHNICAL DATA DATI TECNICI PER DIMENSIONAMENTO CANNA FUMARIA che deve comunque rispettare le indicazioni della presente scheda e delle norme di installazione di ogni prodotto VYDA2 H 22 UP VYDA2 H18 UP KIRA2 H 22 UP KIRA2 H 18 UP Potenza Nominale Potenza Ridotta Temperatura uscita fumi allo scarico...
  • Page 10 ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 AND ECOLABEL REQUIREMENTS FOR SOLID FUEL BOILERS ACCORDING TO COMMISSION REGULATION (EU) 2015/1186 EDILKAMIN – VYDA2 H 22 UP, BLADE2 H 22 UP, KIRA2 H 22 UP ITALIANA CAMINI – LAYMA2 IDRO 22 Indirect heating functionality: YES...
  • Page 11 ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 AND ECOLABEL REQUIREMENTS FOR SOLID FUEL BOILERS ACCORDING TO COMMISSION REGULATION (EU) 2015/1186 EDILKAMIN – VYDA2 H 18 UP, BLADE2 H 18 UP, KIRA2 H 18 UP ITALIANA CAMINI – LAYMA2 IDRO 18 Indirect heating functionality: YES...
  • Page 12: Preparation And Unpacking

    KIRA H - VYDA H UNPACKING PREPARATION AND UNPACKING The packaging materials are neither toxic nor noxious The packaging materials are neither toxic nor noxious and do not require special disposal. and do not require special disposal. The user is responsible for storing, disposing of and The user is responsible for storing, disposing of and recycling them in a regulatory fashion.
  • Page 13 KIRA H UNPACKING The drawings are for guidance only, useful for DO NOT TRY TO REMOVE THE PRODUCT FROM THE PALLET WITHOUT HAVING the installation, but they may not refer to the OPENED THE COMBUSTION CHAMBER specific model. DOOR AND UNDONE THE SCREWS WHICH FIX IT TO THE PALLET TO REMOVE KIRA H FROM THE PALLET To remove the boiler stove from the pallet you must (see figures below corresponding to instructions):...
  • Page 14 CONNECTING THE FUME EXHAUST PIPE THE EXHAUST PIPE TO BE CONNECTED The drawings are for guidance only, useful for TO THE FUME MOTOR IS LOCATED IN THE the installation, but they may not refer to the PELLET TANK. specific model. 1.
  • Page 15: Water Circuit Installation

    OTHER HYDRAULIC COMPONENTS BE INSTALLED WITHIN THE BOILER STOVE BY PURCHASING A KIT FROM EDILKAMIN OR IF PREPARED BY THE INSTALLER. Plumbing depends on the type of system. However, there are some “general rules”: • The hydraulic system must operate at a pressure between 1 and 1.5-2 bar at running temperature...
  • Page 16 WATER CIRCUIT INSTALLATION PIPE KIT Measurements in mm this line indicates the floor this line indicates the floor KIT R-RW Template hydraulic fittings in mm KIT R2 Template hydraulic fittings in mm ONLY FOR COLD H HEATING DELIVERY HEATING DELIVERY HEATING RETURN SAFETY DISCHARGE SAFETY DISCHARGE...
  • Page 17: Installation

    Contact the authorised Edilkamin Technical Assistance that the air inlet is connected to the outside. Centre. •...
  • Page 18: Flue System

    INSTALLATION FLUE SYSTEM FLUE SYSTEM THE SMOKE DUCT THE SMOKE DUCT ( ( Fumes duct, flue and chimney pot Fumes duct, flue and chimney pot) ) In addition to the general requirements for the fume This chapter has been drawn up pursuant to European duct and the flue, the fume duct: : regulations EN 13384, EN 1443, EN 1856 and EN •...
  • Page 19: External Air Intake

    INSTALLATION THE FLUE THE FLUE: EXTERNAL AIR INTAKE In addition to the general instructions applicable to the In general, we suggest two alternative ways for ensuring fume duct and the flue, the flue: : a proper flow of indispensable combustion air. •...
  • Page 20: Checking The Electrical Connections

    (the power socket must be located in an particular. easy-to-access position) Edilkamin responsible The stove is equipped with an electrical power cord or malfunctions resulting from an improperly connection to a 230V 50 Hz socket, preferably with an earthed system.
  • Page 21 KIRA H- LINING Description Reference in Figures below Quantity Bottom front panel no.1 Top front panel no.1 Top right ceramic side no.1 Lower right ceramic side no.1 Lower left ceramic side no.1 Top left ceramic side no.1 Ceramic top no.1 3,4,5,6 The position of each ceramic side is indicated on the interior part of each piece (example BTM.
  • Page 22 KIRA H- LINING Fitting of the bottom front panel (1) 1. Open the combustion chamber door with the protective lever (removable handle P) and undo two screws to remove the bottom metal front panel 2. Fit the ceramic part on the bottom metal front panel using the M4 screws with washers Do not force the screw into the pin, it may break...
  • Page 23 KIRA H- LINING Fitting of the top front panel (2) 1. Undo the two upper screws. 2. Remove the metal support (S). 3. Place the top ceramic front panel (2) on the metal support (S). Fit the front panel (2) with the M4 screws provided with washers 4.
  • Page 24 KIRA H CLADDING Fitting the ceramic sides (3,4,5,6) THE DRAWINGS ARE FOR GUIDANCE ONLY, USEFUL FOR THE INSTALLATION, BUT The sides are hooked and screwed on top THEY MAY NOT REFER TO THE SPECIFIC Start from the bottom ceramic part of one of the two sides. MODEL.
  • Page 25 KIRA H- LINING Fitting the ceramic top (7) The top part of the lining consists of a grille (G) for the hot air output and the stone or ceramic top (4). 1. Fit the two rubber buffers provided on the top part of the grille.
  • Page 26 VYDA H- LINING Description Reference in the Quantity Figure below Front panel above the door (ceramic or stone) Top front panel (ceramic or stone) Left or right interchangeable sides (ceramic or stone) Top (ceramic or stone) The metal grille of the top is in the stove structure package together with the M4 screws (and M6 for the stone top), the fitting washers and the two rubber buffers * Small parts to be used for Vyda H: •...
  • Page 27 VYDA H- LINING Fitting of the stone or ceramic front panel above the door (1) 1. Open the combustion chamber door with the protective lever (removable handle P) and undo two screws to remove “aesthetic cover”. aesthetic cover 2. Unscrew the two upper screws, insert the ceramic or stone front panel (1) in the metal support above the door.
  • Page 28 VYDA H- LINING 3. Refit the “aesthetic cover” aesthetic cover 4. Screw it back with the two screws removed in point INSTALLER...
  • Page 29 VYDA H- LINING Fitting of the stone or ceramic top front panel 1. undo the two upper screws 2. remove the metal support (S) 3. Place the top ceramic or stone front panel (2) on the metal support (S). Fit the front panel (2) with the screws provided: M4 with washers for the ceramic front panel;...
  • Page 30 VYDA H- LINING Fitting of the stone or ceramic sides (3) The sides (3) are only hooked on. 1. Place the rubber buffers and hook the sides to the structure Note: see the diagram for correct installation of the ceramic tile rubber buffers To make alignment adjustments between ceramic/ stone and the door, you can move the top or bottom...
  • Page 31 VYDA H- LINING Fitting of the stone or ceramic top (4) The top part of the lining consists of a grille (G) for the hot air output and the stone or ceramic top (4). 1. Fit the two rubber buffers provided on the top part of rubber buffers the grille.
  • Page 32 INTRODUCTION ABOUT USE FIRST IGNITION (COMMISSIONING) PHASES LOADING THE PELLETS INTO THE TANK. • Make sure you have read and understood this To access the tank, open the lid. manual. • Remove all flammable materials from the appliance When the boiler stove is hot, DO NOT (manuals, labels, etc.).
  • Page 33 DISPLAY INTERFACE The product is provided with a pop-up panel on the top. It can be opened by slightly rotating it. On the top left side of the panel there is a lever. To close the panel, move the lever to the left, looking at the stove frontally, and rotate the panel backwards.
  • Page 34: Operation

    USER INSTRUCTIONS OPERATION The product also has the following supplementary Mode Settable parameters functions. AUTOMATIC • desired room temperature • ventilation level * Function Modes in which What it does CRONO • desired room temperature, it can be acti- selected per day of the week vated •...
  • Page 35: Introduction To Use

    INTRODUCTION TO USE INTERFACE The product can be managed alternatively as follows STANDARD • DISPLAY: useful for all functions, located on By purchasing the Edilkamin optional elements: the product • VOICE CONTROL SYSTEMS: Alexa or Google Home • The Mind APP...
  • Page 36 OPTIONAL THERMOSTATS/PROBES CONNECTIONS OPTIONAL ELECTRICAL CONNECTIONS NOTE: The connections must be made by qualified A terminal board is present on the product (accessible personnel, with the electricity disconnected. by removing the covering, with electricity off and only by qualified technicians). More info for installers on the site.
  • Page 37 INTRODUCTION TO USE The displays follow the functions at the same time and are described in the following paragraphs: 15:40 14.9 ° 1.2 bar - BUTTONS The display has 8 buttons: ON/OFF: to go from the OFF status to the ON status. In the Menus, to confirm and return to the main screen. +/-: to increase/decrease the set values or scroll the menu items M: to access the Menu or to exit the Menu items without saving OK: to confirm an operation (2 seconds) or to access a menu item...
  • Page 38 USER INSTRUCTIONS From the display it is possible to: Switching on and off takes a few minutes, • Switch from OFF to ON status, during which the flame must appear or keeping the ON/OFF button pressed for a go out. Let it happen without intervening. long time During ignition, the display shows the word •...
  • Page 39: Fan Adjustment

    USER INSTRUCTIONS - FAN ADJUSTMENT The setting can be made with the stove turned OFF or ON. If the backlight is switched off, it can be activated by pressing any button. Then by pressing button SET flashes and instead of environment Set, the indication of the number of fan in modification (F1) appears.
  • Page 40: Alarm Status

    USER INSTRUCTIONS POSSIBLE STATUSES of the product: - OFF STATUS The product is “deactivated” and does not produce heat, following manual shutdown with ON/OFF of the radio control or with intervention from an external contact (crono, telephone dialler). From the OFF screen, the ON screen can be accessed by pressing the ON/OFF button for 3 seconds. - ON STATUS Situation in which the product is “active”...
  • Page 41 USER INSTRUCTIONS - MENU It can be accessed by pressing the button and the first Menu item will appear. You can scroll the menu items with the buttons, and enter the item with the button The Menu items are as follows STAND-BY PELLET LOAD CRONO...
  • Page 42 USER INSTRUCTIONS - STAND-BY With the Stand-by function active, when the desired temperature is reached, the product switches off and switches on again when the room temperature drops below the desired one. When the Stand-by function is not active, the product sets itself to minimum power when the temperature set-point is reached.
  • Page 43: Pellet Loading

    USER INSTRUCTIONS - PELLET LOADING Allows for loading the pellets once the screw feeder has emptied completely. Useful for the technician during the initial start-up. Available only in the OFF status. Any attempt to activate the function in other statuses will not be allowed. To access the function from the main menu (as indicated in the Menu paragraph above), press the button You can scroll the menu items with the...
  • Page 44 USER INSTRUCTIONS - CRONO SETTING To access the function from the main menu (as indicated in the Menu paragraph above), press the button You can scroll the menu items with the buttons, and enter the item with the button 15:36 14.9 °...
  • Page 45 USER INSTRUCTIONS The day of the week is selected by scrolling with buttons (at the same time the programming of that day is displayed) and confirmed with button day of the week 00:00 15:36 e.g. = MON = Monday 14.9 °...
  • Page 46 USER INSTRUCTIONS SETTING TEMPERATURE FOR CRONO T1 – T2 TEMP. CRONO To access the function from the main menu (as indicated in the Menu paragraph above), press the button You can scroll the menu items with the buttons, and enter the item with the button After entering the T1-T2 function, the display will show the name of the function on the first line of the status bar and the current value of T1 on the second line.
  • Page 47: Date And Time

    USER INSTRUCTIONS - DATE AND TIME Can be used to set the current date and time. To access the function from the main menu (as indicated in the Menu paragraph above), press the button You can scroll the menu items with the buttons, and enter the item with the button 15:36...
  • Page 48: Language Setting

    USER INSTRUCTIONS - LANGUAGE SETTING Selects the language. To access the function from the main menu (as indicated in the Menu paragraph above), press the button You can scroll the menu items with the buttons, and enter the item with the button When entering the Language Menu item, the name in the status bar on the first line of the function and on the second the current value is displayed (ITALIAN)
  • Page 49: For The Installer

    FOR INSTALLER INSTRUCTIONS FOR USE: MENU It can be accessed by pressing the button and the first Menu item will appear. You can scroll the menu items with the buttons, and enter the item with the button The Menu items are as follows STAND-BY: described in the user manual NOTE PELLET LOAD: described in the user manual...
  • Page 50 USER INSTRUCTIONS - DISPLAY Allows for choosing the level of brightness of the display. - INFO These readings should only be done when requested by the technician. The technician understands the diagnostic meaning of the messages and values, and may ask you to read them to him/her if you experience problems.
  • Page 51 USER INSTRUCTIONS - SOFTWARE Indicates: • the firmware version of the electronic board (basic board) • the firmware version of the control panel • the database (associated by the Technical Assistance Centres with the products) To be read only under the guidance of the Technical Assistance Centre 15:36 °...
  • Page 52 USER INSTRUCTIONS - INFO They provide instant situation values 15:36 ° 14.9 INFO 15:36 ° 14.9 FLUE TEMPERATURE 88.2°C Below is a description of the items Flue temperature indicates the value of the temperature read inside the product. To be read only under the guidance of the Technical Assistance Centre Auger motor: indicates the speed set and read.
  • Page 53 USER INSTRUCTIONS - ALARMS These readings should only be done when requested by the technician. The alarms are arranged from the most recent to the oldest. 15:36 ° 14.9 ALARMS 15:36 ° 14.9 ALARMS A4 28/12/2020 The meaning of the abbreviations is given in the user manual USER...
  • Page 54 USER INSTRUCTIONS - PELLET FALL Allows to set the gearmotor in continuous cycle or in steps. To be carried out only under the guidance of a technician. 15:36 ° 14.9 PELLET FALL 15:36 ° 14.9 PELLET FALL CONTINUES - PELLET SENSOR Allows to set the pellet level sensor ON or OFF.
  • Page 55 USER INSTRUCTIONS IN ORDER OF SCROLLING IT IS FOUND AFTER THE TECHNICAL MENU - “SET TEMPERATURE” o the display (Setting the water temperatures) Allows the setting of the boiler temperature and possibly the storage temperature. If the external probe is activated, it allows the setting of the climatic curve instead of the boiler temperature.
  • Page 56: Technician Menu

    INSTRUCTIONS FOR USE: TECHNICIAN MENU - TECHNICIAN MENU (for TECHNICIANS ONLY) Accessible only by a technician in possession of the correct password (1111) Once the password has been entered, it must be confirmed with a button - Flame type NOTES - Pellet type inappropriate changes can cause the product to seize up...
  • Page 57 INSTRUCTIONS FOR USE: TECHNICIAN MENU - PELLET TYPE In correct installation conditions, with the Service Centre parameters appropriately adjusted, with quality pellets, the pellet load is adjusted MEDIUM HIGH 15:36 ° 14.9 PELLET TYPE Enter the Pellet Type (%) setting with button and modify the value with buttons Pressing the button automatically takes you to the first level.
  • Page 58 INSTRUCTIONS FOR USE: TECHNICIAN MENU - CONFIGURATION Scroll through the Technician Menu items with buttons to the “CONFIGURATION” item It is possible to enter the “CONFIGURATION” setting with button and modify the value with buttons Pressing the button automatically takes you to the first level. 15:36 °...
  • Page 59 FOR THE INSTALLER: HYDRAULIC INSTALLATION To manage the various types of systems, connect the probes to the terminal board, as needed. TERMINAL BOARD MAIN OUTLINE 15-16 CYLINDER PROBE (Optional NTC 10K ) or THERMOSTAT (Optional) 13-14 DOMOTIC CONTACT (Input) 11-12 ROOM PROBE (Supplied) or ROOM THERMOSTAT (Optional) 9-10 BUFFER PROBE (Optional NTC 10K) - BUFFER THERMOSTAT (Optional)
  • Page 60 FOR THE INSTALLER: INSTALLATION DIRECT HEATING (possibly with combined boiler) IT IS the “O” configuration in the parameters. The product modulates depending on the water temperature and turns on/off according to the ambient temperature (probe or thermostat T) or, at the choice of the installer, according to the water temperature.
  • Page 61 FOR THE INSTALLER: INSTALLATION HEATING WITH PUFFER (inertial storage) IT IS the “1” configuration in the parameters. The product modulates according to the water temperature and turns on / off according to the PUFFER temperature (P). The ambient temperature of the thermostat (T) or of the probe controls the secondary circuit pump (P2) NOTE: PURELY INDICATIVE DIAGRAMS.
  • Page 62 FOR THE INSTALLER: INSTALLATION In addition to the pre-set configurations, the product can be installed on integrated systems (example below) with probes and thermostats. NOTE: PURELY INDICATIVE DIAGRAMS. THEY DO NOT REPLACE THE LEGAL OBLIGATIONS IN ANY WAY AS REGARDS THE DRAFTING OF ANY PROJECT. ALL LOCAL AND NATIONAL REGULATIONS MUST BE COMPLIED WITH INSTALLER...
  • Page 63: Daily Maintenance

    MAINTENANCE DAILY MAINTENANCE These jobs should be done with the product off, cold and preferably disconnected from the mains. A suitable vacuum cleaner is required. Disconnect the product from the Make sure that the grate is power supply. properly placed in its Failure service product...
  • Page 64 MAINTENANCE Disconnect the product from the power supply. Failure to service the product properly will prevent it from working properly. Any problems due to failure in servicing the stove will void the warranty. Do not dump the cleaning residue into the pellet tank. Once it is refitted, make sure that the ash tray is properly placed in its housing, to avoid glass breakage when closing.
  • Page 65: Weekly Maintenance

    MAINTENANCE WEEKLY MAINTENANCE When the product is off and cold, after having activated the cleaning brush as in routine maintenance, you should vacuum the inspection plate under the combustion chamber (*) To do so: • Remove the protection, by turning the winget nut (V) •...
  • Page 66: Seasonal Maintenance

    - If any spare parts are required, contact your dealer You should clean the chimney system at least once a or technician. - Have any repairs carried out only by Edilkamin year (check local regulations for details). technical assistance centres/authorised dealers.
  • Page 67: Troubleshooting

    TROUBLESHOOTING If problems occur, the product shuts itself off automatically. The display will show the reason (see below). 15:36 14.9 ° BURNING POT DIRTY MESSAGE PROBLEM SOLUTION • Check that the combustion chamber door is closed A01 burning pot displays when the combustion •...
  • Page 68 TROUBLESHOOTING MESSAGE PROBLEM SOLUTION • Check the type of pellet (contact the technician if in Shutdown due to exceeding doubt) maximum smoke temperature. • contact the technician Switching OFF due to excessive • see HO7 overheating of the product Shutdown due to gearmotor •...
  • Page 69 If the water in the product reaches a temperature of 85°C, the product shuts down without switching to alarm mode. The text STBY appears on the display next to the room temperature. The product is working, but it must be serviced by an authorised Edilkamin technician. MAINTENANCE (SIGNAL THAT DOES NOT CAUSE SHUTDOWN) A spanner symbol will appear on the display after 2,000 hours of operation The product is working, but it must be serviced by an authorised Edilkamin technician.
  • Page 72 The names of Edilkamin official, authorised technical assistance centres and distributors are available ONLY a www.edilkamin.com *942415-GB* w w w . e d i l k a m i n . c o m cod. 942415-GB 05.22/B...