Chapter 1 General Information
1.1 Features
Lists key features of the PM130 PLUS powermeter series.
1.2 Available Options
Details optional expansion modules for the PM130 PLUS.
1.3 Customized Options
Explains options for customizing data presentation.
1.4 Measured Parameters
Lists all parameters that can be measured by the PM130 PLUS.
Chapter 2 Installation
2.1 Site Requirements
Lists environmental and electrical requirements for installation.
2.2 Package Contents
Details the items included in the PM130 PLUS powermeter package.
2.3 Mechanical Installation
Covers physical installation steps for the PM130 PLUS unit.
2.4 Electrical Installation
Details the electrical connection procedures for the PM130 PLUS.
2.5 DC Measurement
Explains how to perform DC voltage and current measurements.
2.6 I/O Connections
Describes connections for digital and analog input/output modules.
2.7 Communications Connections
Details how to establish communication connections for the PM130 PLUS.
Chapter 3 Using Front Display
3.1 Indicators and Controls
Explains the front panel indicators and control buttons of the PM130 PLUS.
3.2 Data Display
Describes how data is displayed on the PM130 PLUS front panel.
3.3 Status Display
Details the status display for troubleshooting and external equipment connection.
3.4 Using the Menus
Explains how to navigate and use the meter's menu system.
Chapter 5 Configuring the PM130 PLUS
5.1 Configuring Communications
Guides on configuring communication ports and settings for the PM130 PLUS.
5.2 General Meter Setup
Covers essential meter settings like wiring, frequency, and load current.
5.3 Configuring Meter Security
Explains how to set up user passwords and enable/disable password protection.
5.4 Configuring Billing/TOU
Details configuration of billing registers, tariff rates, and TOU schedules.
5.5 Configuring Recorders
Describes how to set up data and event logging memory configurations.
5.6 Configuring Communication Protocols
Details configuration options for Modbus, DNP3, and other communication protocols.
Chapter 9 Viewing Files
9.1 Operations with Files
Explains how to open and save data files in the meter database.
9.2 Viewing Options
Covers customizing display settings like date order and timestamp format.
9.3 Viewing the Event Log
Describes how to view time-tagged events related to configuration, resets, and diagnostics.
9.4 Viewing the Data Log
Explains how to view data log files in tabular or graphical trend format.
Appendix A Technical Specifications
A.1 Environmental Conditions
Lists operating and storage temperature, and humidity specifications.
A.2 Construction
Details the materials and dimensions used in the PM130 PLUS construction.
A.3 Power Supply
Specifies the voltage and current ratings for different power supply options.
A.4 Input Ratings
Details the voltage and current input ranges and burdens.
A.5 Optional Relay Outputs
Describes the specifications for electromechanical and solid-state relay outputs.
A.6 Optional Digital Inputs
Lists the specifications for the optional digital input modules.
A.7 Optional Analog Outputs
Details the specifications for the optional analog output modules.
A.8 Communication Ports
Lists the specifications for COM1 and COM2 communication ports.
A.9 Real-time Clock
Provides accuracy and retention time for the meter's real-time clock.
A.10 Display
Describes the features of the PM130 PLUS display and keypad.
A.11 Standards Compliance
Lists the standards the PM130 PLUS complies with for accuracy and safety.
A.12 Measurement Specifications
Details accuracy and range specifications for various electrical measurements.
Quick Start Guide
1. Installing the PM130 PLUS
Provides basic steps for installing the PM130 PLUS unit.
Mounting the PM130 PLUS Unit
Details the process of physically mounting the PM130 PLUS unit.
Chapter 1 General Information
1.1 Features
Lists key features of the PM130 PLUS powermeter series.
1.2 Available Options
Details optional expansion modules for the PM130 PLUS.
1.3 Customized Options
Explains options for customizing data presentation.
1.4 Measured Parameters
Lists all parameters that can be measured by the PM130 PLUS.
Chapter 2 Installation
2.1 Site Requirements
Lists environmental and electrical requirements for installation.
2.2 Package Contents
Details the items included in the PM130 PLUS powermeter package.
Chapter 2 Installation
2.3 Mechanical Installation
Covers physical installation steps for the PM130 PLUS unit.
2.3.1 Panel Mounting
Details the procedure for mounting the meter in a panel cutout.
Chapter 2 Installation
2.3 Mechanical Installation
Covers physical installation steps for the PM130 PLUS unit.
2.3.2 DIN Rail Mounting
Describes how to mount the PM130 PLUS on a 35-mm DIN rail.
Chapter 2 Installation
2.4 Electrical Installation
Details the electrical connection procedures for the PM130 PLUS.
2.4.1 Typical Installation
Provides a general diagram for typical electrical installation.
2.4.2 Terminals
Identifies and shows the rear view terminal connections.
Chapter 2 Installation
2.4 Electrical Installation
Details the electrical connection procedures for the PM130 PLUS.
2.4.3 Power Source Connection
Explains how to connect AC and DC power supplies to the meter.
Chapter 2 Installation
2.4 Electrical Installation
Details the electrical connection procedures for the PM130 PLUS.
2.4.4 Voltage Input connection
Details how to connect voltage inputs for 690V and 120V systems.
Chapter 2 Installation
2.4 Electrical Installation
Details the electrical connection procedures for the PM130 PLUS.
2.4.5 Current Input Connection
Explains how to connect external CTs for current input.
Chapter 2 Installation
2.4 Electrical Installation
Details the electrical connection procedures for the PM130 PLUS.
2.4.6 Wiring Diagrams
Presents various wiring configurations for the PM130 PLUS.
Chapter 2 Installation
2.5 DC Measurement
Explains how to perform DC voltage and current measurements.
2.5.1 DC voltage measurement
Details how to measure DC voltage sources using the meter.
Chapter 2 Installation
2.5 DC Measurement
Explains how to perform DC voltage and current measurements.
2.5.2 DC Current measurement (Hall Effect Sensors)
Explains DC current measurement using Hall Effect sensors.
Chapter 2 Installation
2.6 I/O Connections
Describes connections for digital and analog input/output modules.
2.6.1 4DI/2DO Module
Details the 4 Digital Inputs and 2 Relay Outputs module.
Chapter 2 Installation
2.6 I/O Connections
Describes connections for digital and analog input/output modules.
2.6.2 8 DI module
Details the 8 Digital Inputs module.
2.6.3 12DI/4RO Module
Details the 12 Digital Inputs and 4 Relay Outputs module.
Chapter 2 Installation
2.6 I/O Connections
Describes connections for digital and analog input/output modules.
2.6.4 4AO Module - Analog Outputs
Details the 4 Analog Output module.
Chapter 2 Installation
2.6 I/O Connections
Describes connections for digital and analog input/output modules.
2.6.5 TOU module – RTC and 4 Digital Inputs
Details the TOU module with Real-Time Clock and 4 Digital Inputs.
Chapter 2 Installation
2.7 Communications Connections
Details how to establish communication connections for the PM130 PLUS.
2.7.1 COM1 RS-485 Connection
Explains how to connect to the COM1 RS-485 port.
Chapter 2 Installation
2.7 Communications Connections
Details how to establish communication connections for the PM130 PLUS.
2.7.2 ETH module – COM2 Ethernet Connection
Explains how to connect the COM2 Ethernet module.
Chapter 2 Installation
2.7 Communications Connections
Details how to establish communication connections for the PM130 PLUS.
2.7.3 PRO module – COM2 PROFIBUS Connection
Explains how to connect the COM2 PROFIBUS module.
Chapter 2 Installation
2.7 Communications Connections
Details how to establish communication connections for the PM130 PLUS.
2.7.4 RS-232/422-485 module – COM2 Connection
Explains how to connect the COM2 RS-232/422-485 module.
Chapter 2 Installation
2.7 Communications Connections
Details how to establish communication connections for the PM130 PLUS.
2.7.5 Connecting a GSM/GPRS modem
Describes how to connect a GSM/GPRS modem module for wireless communication.
2.7.6 Connecting a WiFi module
Describes how to connect a WiFi module for wireless communication.
Chapter 3 Using Front Display
3.1 Indicators and Controls
Explains the front panel indicators and control buttons of the PM130 PLUS.
3.2 Data Display
Describes how data is displayed on the PM130 PLUS front panel.
3.3 Status Display
Details the status display for troubleshooting and external equipment connection.
3.4 Using the Menus
Explains how to navigate and use the meter's menu system.
Chapter 4 Using PAS Software
4.1 Installing PAS
Guides on how to install the PAS software on a PC.
Chapter 4 Using PAS Software
4.2 Creating a New Site for your Meter
Explains how to create a new site database in PAS for meter configuration.
Chapter 4 Using PAS Software
4.3 Setting up Communications
Guides on configuring communication settings for the PM130 PLUS via PAS.
4.3.1 Communicating through a Serial Port
Details the process of setting up serial port communication in PAS.
Chapter 4 Using PAS Software
4.3 Setting up Communications
Guides on configuring communication settings for the PM130 PLUS via PAS.
4.3.2 Communicating through the Internet
Details the process of setting up internet communication in PAS.
Chapter 4 Using PAS Software
4.4 Setting Up the Meter
Explains how to prepare and manage meter setup configurations using PAS.
4.4.1 Preparing Setups for the Meter
Guides on preparing meter setup data offline using PAS.
Chapter 4 Using PAS Software
4.4 Setting Up the Meter
Explains how to prepare and manage meter setup configurations using PAS.
4.4.2 Downloading Setups to the Meter
Details how to download meter setups from PAS to the device.
4.4.3 Uploading Setups from the Meter
Details how to upload meter setups from the device to PAS.
Chapter 4 Using PAS Software
4.5 Authorization
Explains the authorization process when sending setup data to a secured meter.
Chapter 5 Configuring the PM130 PLUS
5.1 Configuring Communications
Guides on configuring communication ports and settings for the PM130 PLUS.
5.1.1 Setting Up Serial Communication Ports
Guides on configuring serial communication ports for the PM130 PLUS.
Chapter 5 Configuring the PM130 PLUS
5.1 Configuring Communications
Guides on configuring communication ports and settings for the PM130 PLUS.
5.1.2 Setting Up Ethernet
Guides on configuring Ethernet network settings for the PM130 PLUS.
Chapter 5 Configuring the PM130 PLUS
5.1 Configuring Communications
Guides on configuring communication ports and settings for the PM130 PLUS.
5.1.3 Setting Up GPRS Network
Guides on configuring GPRS network settings for wireless communication.
Chapter 5 Configuring the PM130 PLUS
5.1 Configuring Communications
Guides on configuring communication ports and settings for the PM130 PLUS.
5.1.4 Setting Up WiFi Network
Guides on configuring WiFi network settings for wireless communication.
Chapter 5 Configuring the PM130 PLUS
5.1 Configuring Communications
Guides on configuring communication ports and settings for the PM130 PLUS.
5.1.5 Setting Up eXpertPower Client
Guides on setting up the eXpertPower client for server communication.
Chapter 5 Configuring the PM130 PLUS
5.1 Configuring Communications
Guides on configuring communication ports and settings for the PM130 PLUS.
5.1.6 Setting Up TCP Notification Client
Guides on setting up the TCP notification client for server communication.
Chapter 5 Configuring the PM130 PLUS
5.2 General Meter Setup
Covers essential meter settings like wiring, frequency, and load current.
5.2.1 Basic Meter Setup
Details essential meter configuration based on electrical network.
Chapter 5 Configuring the PM130 PLUS
5.2 General Meter Setup
Covers essential meter settings like wiring, frequency, and load current.
5.2.2 Device Options
Allows changing user-configurable device options or entering energy test mode.
Chapter 5 Configuring the PM130 PLUS
5.2 General Meter Setup
Covers essential meter settings like wiring, frequency, and load current.
5.2.3 Configuring Digital Inputs
Explains how to configure digital inputs for status, pulse counting, or TOU registers.
Chapter 5 Configuring the PM130 PLUS
5.2 General Meter Setup
Covers essential meter settings like wiring, frequency, and load current.
5.2.4 Configuring Relay Outputs
Explains how to configure relay outputs for alarms, control, or energy pulses.
Chapter 5 Configuring the PM130 PLUS
5.2 General Meter Setup
Covers essential meter settings like wiring, frequency, and load current.
5.2.5 Configuring Analog Outputs
Explains how to configure analog outputs for transmitting measured parameters.
Chapter 5 Configuring the PM130 PLUS
5.2 General Meter Setup
Covers essential meter settings like wiring, frequency, and load current.
5.2.6 Configuring Counters
Explains how to configure general counters for pulses or setpoint operation time.
Chapter 5 Configuring the PM130 PLUS
5.2 General Meter Setup
Covers essential meter settings like wiring, frequency, and load current.
5.2.7 Configuring Alarm/Control Setpoints
Explains how to configure setpoints for actions based on measured values.
Chapter 5 Configuring the PM130 PLUS
5.2 General Meter Setup
Covers essential meter settings like wiring, frequency, and load current.
5.2.8 Configuring the Display
Guides on configuring display parameters like update rate and brightness.
Chapter 5 Configuring the PM130 PLUS
5.2 General Meter Setup
Covers essential meter settings like wiring, frequency, and load current.
5.2.9 Local Time Settings
Allows setting time zone, daylight saving time, and clock synchronization.
Chapter 5 Configuring the PM130 PLUS
5.3 Configuring Meter Security
Explains how to set up user passwords and enable/disable password protection.
Chapter 5 Configuring the PM130 PLUS
5.4 Configuring Billing/TOU
Details configuration of billing registers, tariff rates, and TOU schedules.
Chapter 5 Configuring the PM130 PLUS
5.4 Configuring Billing/TOU
Details configuration of billing registers, tariff rates, and TOU schedules.
5.4.1 Configuring Billing/Tariff Registers
Explains how to configure billing and TOU registers for energy sources.
Chapter 5 Configuring the PM130 PLUS
5.4 Configuring Billing/TOU
Details configuration of billing registers, tariff rates, and TOU schedules.
5.4.2 Configuring the Daily Tariff Schedule
Explains how to set up daily tariff change points for seasons and day types.
Chapter 5 Configuring the PM130 PLUS
5.4 Configuring Billing/TOU
Details configuration of billing registers, tariff rates, and TOU schedules.
5.4.3 Configuring the Season Tariff Schedule
Explains how to configure the season tariff schedule using the TOU calendar.
Chapter 5 Configuring the PM130 PLUS
5.5 Configuring Recorders
Describes how to set up data and event logging memory configurations.
5.5.1 Configuring Meter Memory
Guides on viewing and setting up memory allocation for log files.
Chapter 5 Configuring the PM130 PLUS
5.5 Configuring Recorders
Describes how to set up data and event logging memory configurations.
5.5.2 Configuring the Event Recorder
Explains how to configure the event log file settings.
5.5.3 Configuring the Data Recorder
Explains how to create or re-configure conventional data log files.
Chapter 5 Configuring the PM130 PLUS
5.6 Configuring Communication Protocols
Details configuration options for Modbus, DNP3, and other communication protocols.
5.6.1 Configuring Modbus
Guides on configuring Modbus point mapping and register format.
Chapter 5 Configuring the PM130 PLUS
5.6 Configuring Communication Protocols
Details configuration options for Modbus, DNP3, and other communication protocols.
5.6.2 Configuring DNP3
Guides on configuring DNP3 protocol options and data points.
Chapter 5 Configuring the PM130 PLUS
5.6 Configuring Communication Protocols
Details configuration options for Modbus, DNP3, and other communication protocols.
5.6.3 Configuring DNP Class 0 Responses
Explains how to configure DNP Class 0 responses for polling points.
Chapter 6 Device Control and Upgrading
6.1 Resetting Accumulators, Maximum Values and Files
Guides on resetting meter data like energies, demands, logs, and counters.
Chapter 6 Device Control and Upgrading
6.2 Updating the Meter Clock
Explains how to change the meter's time and date settings.
Chapter 6 Device Control and Upgrading
6.3 Viewing and Clearing Device Diagnostics
Guides on viewing and clearing device diagnostic codes and messages.
Chapter 6 Device Control and Upgrading
6.4 Viewing Communication Status and Statistics
Describes how to view GPRS status and TCP client connection statistics.
Chapter 6 Device Control and Upgrading
6.5 Remote Relay Control
Explains how to send remote commands to operate or release meter relays.
Chapter 6 Device Control and Upgrading
6.6 Upgrading Device Firmware
Guides on how to download and upgrade the meter's firmware via PAS.
Chapter 7 Monitoring Meters
7.1 Viewing Real-time Data
Describes how to retrieve and view real-time data from the meter.
7.1.1 Polling Devices
Explains how to poll the meter for data retrieval.
Chapter 7 Monitoring Meters
7.1 Viewing Real-time Data
Describes how to retrieve and view real-time data from the meter.
7.1.2 Organizing Data Sets
Explains how to organize and manage data sets in PAS.
7.1.3 Polling Options
Details how to configure polling options, including error handling.
7.1.4 Viewing a Data Table
Explains how to view data in a tabular format.
Chapter 7 Monitoring Meters
7.1 Viewing Real-time Data
Describes how to retrieve and view real-time data from the meter.
7.1.5 Viewing Data Trend
Explains how to view data trends in a graphical format.
7.1.6 Saving Data to a File
Guides on saving retrieved data to a file for analysis.
7.1.7 Printing Data
Explains how to print retrieved data reports.
7.1.8 Real-time Data Logging
Guides on setting up automatic real-time data logging to a database.
7.2 Viewing Real-time Min/Max Log
Describes how to retrieve and view the meter's real-time Min/Max log data.
Chapter 7 Monitoring Meters
7.3 Viewing Real-time Waveforms
Describes how to retrieve and view real-time voltage and current waveforms.
7.3.1 Viewing a Waveform Graph
Explains how to view waveforms in a graph format.
Chapter 7 Monitoring Meters
7.3 Viewing Real-time Waveforms
Describes how to retrieve and view real-time voltage and current waveforms.
7.3.2 Viewing a Frequency Plot
Explains how to view a cycle-by-cycle frequency plot.
7.3.3 Viewing a Harmonic Spectrum
Explains how to view voltage, current, and power harmonic spectrum charts.
7.3.4 Viewing Phasor Diagrams
Describes how to view phasor diagrams for voltage and current fundamental components.
7.3.5 Viewing Symmetrical Components
Explains how to view symmetrical components for voltages and currents.
7.3.6 Viewing Phase-to-phase Voltages
Explains how to view phase-to-phase voltages from phase-to-neutral waveforms.
Chapter 7 Monitoring Meters
7.4 Viewing Real-time Harmonic Spectrum
Describes how to retrieve real-time harmonic spectrum data from the meter.
Chapter 7 Monitoring Meters
7.4 Viewing Real-time Harmonic Spectrum
Describes how to retrieve real-time harmonic spectrum data from the meter.
7.4.1 Viewing a Spectrum Chart
Explains how to view a spectrum chart for selected channels and harmonic limits.
Chapter 7 Monitoring Meters
7.4 Viewing Real-time Harmonic Spectrum
Describes how to retrieve real-time harmonic spectrum data from the meter.
7.4.2 Viewing a Spectrum Table
Explains how to view harmonic spectrum data in a tabular format.
Chapter 7 Monitoring Meters
7.4 Viewing Real-time Harmonic Spectrum
Describes how to retrieve real-time harmonic spectrum data from the meter.
7.4.3 Viewing Synthesized Waveforms
Explains how to view synthesized waveforms based on harmonic spectrum data.
Chapter 8 Retrieving and Storing Files
8.1 Uploading Files on Demand
Guides on retrieving log files from meters on demand.
Chapter 8 Retrieving and Storing Files
8.2 Using the Upload Scheduler
Explains how to set up the Upload Scheduler for automatic data retrieval.
Chapter 8 Retrieving and Storing Files
8.3 Viewing Files On-line
Describes how to review historical data online without storing it to a file.
Chapter 8 Retrieving and Storing Files
8.4 Exporting Files
Guides on exporting files in COMTRADE, PQDIF, and Excel formats.
8.4.1 Exporting Files in COMTRADE and PQDIF Formats
Explains how to convert waveforms and data logs to COMTRADE or PQDIF.
8.4.2 Manual Converting
Details the process of manually converting waveforms or data logs.
Chapter 8 Retrieving and Storing Files
8.4 Exporting Files
Guides on exporting files in COMTRADE, PQDIF, and Excel formats.
8.4.3 Exporting Files in Excel Format
Explains how to convert data tables into Microsoft Excel workbook format.
Chapter 8 Retrieving and Storing Files
8.5 Archiving Files
Guides on setting up schedules for archiving data files to prevent database growth.
Chapter 9 Viewing Files
9.1 Operations with Files
Explains how to open and save data files in the meter database.
9.1.1 Opening a Database Table
Details the procedure for opening a database table in PAS.
9.1.2 Saving Data to a File
Guides on saving data from an open table to a file.
9.2 Viewing Options
Covers customizing display settings like date order and timestamp format.
9.2.1 Customizing Views
Explains how to customize view settings like date order and timestamp.
Chapter 9 Viewing Files
9.2 Viewing Options
Covers customizing display settings like date order and timestamp format.
9.2.2 Working with Tables
Explains how to customize table appearance and copy data.
9.2.3 Working with Graphic Windows
Explains how to customize graph window appearance and settings.
Chapter 9 Viewing Files
9.3 Viewing the Event Log
Describes how to view time-tagged events related to configuration, resets, and diagnostics.
Chapter 9 Viewing Files
9.4 Viewing the Data Log
Explains how to view data log files in tabular or graphical trend format.
Appendix A Technical Specifications
A.1 Environmental Conditions
Lists operating and storage temperature, and humidity specifications.
A.2 Construction
Details the materials and dimensions used in the PM130 PLUS construction.
A.3 Power Supply
Specifies the voltage and current ratings for different power supply options.
Appendix A Technical Specifications
A.4 Input Ratings
Details the voltage and current input ranges and burdens.
Appendix A Technical Specifications
A.5 Optional Relay Outputs
Describes the specifications for electromechanical and solid-state relay outputs.
A.6 Optional Digital Inputs
Lists the specifications for the optional digital input modules.
A.7 Optional Analog Outputs
Details the specifications for the optional analog output modules.
Appendix A Technical Specifications
A.8 Communication Ports
Lists the specifications for COM1 and COM2 communication ports.
A.9 Real-time Clock
Provides accuracy and retention time for the meter's real-time clock.
Appendix A Technical Specifications
A.10 Display
Describes the features of the PM130 PLUS display and keypad.
A.11 Standards Compliance
Lists the standards the PM130 PLUS complies with for accuracy and safety.
Appendix A Technical Specifications
A.12 Measurement Specifications
Details accuracy and range specifications for various electrical measurements.