Table of Contents

Advertisement

Quick Links

PM130 PLUS Powermeter Series
PM130P/PM130E/PM130EH
Installation and Operation Manual
BG0425 Rev. A21
PM130 PLUS Powermeter Series_Installation Operation and Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PM130E PLUS and is the answer not in the manual?

Questions and answers

Summarization of Contents

Chapter 1 General Information
1.1 Features
Lists the key features and capabilities of the PM130 PLUS powermeter series.
1.2 Available Options
Describes the optional expansion modules available for the PM130 PLUS, such as Digital I/O and communication ports.
1.3 Customized Options
Covers options for customizing data presentation and device behavior to suit specific applications.
1.4 Measured Parameters
Details the various parameters that the PM130 PLUS can measure and display.
Chapter 2 Installation
2.1 Site Requirements
Specifies the necessary environmental and electrical conditions for installing the PM130 PLUS powermeter.
2.2 Package Contents
Lists the items included in the PM130 PLUS powermeter package.
2.3 Mechanical Installation
Provides instructions and dimensions for the physical mounting of the PM130 PLUS unit.
2.4 Electrical Installation
Details the electrical connections and wiring procedures for the PM130 PLUS powermeter.
2.5 DC Measurement
Explains how to perform DC voltage and current measurements using the PM130 PLUS.
2.6 I/O Connections
Describes how to connect Digital Inputs and Relay Outputs using optional I/O modules.
2.7 Communications Connections
Covers the setup and connection of communication ports like RS-485, Ethernet, GPRS, and WiFi.
Chapter 3 Using Front Display
3.1 Indicators and Controls
Identifies and explains the various indicators, buttons, and display elements on the PM130 PLUS front panel.
3.2 Data Display
Details how measurement data is displayed on the PM130 PLUS, including units and features.
3.3 Status Display
Explains how to access and interpret the meter's status information, useful for troubleshooting.
3.4 Using the Menus
Guides the user on navigating through the meter's menu system for configuration and setup.
Chapter 4 Using PAS Software
4.1 Installing PAS
Provides step-by-step instructions for installing the PAS software on a PC.
4.2 Creating a New Site for your Meter
Explains how to create a new site database in PAS for managing meter configurations.
4.3 Setting up Communications
Details how to establish communication between the PAS software and the PM130 PLUS meter.
4.4 Setting Up the Meter
Guides users on preparing and downloading meter configurations using the PAS software.
4.5 Authorization
Covers the authorization process required when sending setup data to a secured meter.
Chapter 5 Configuring the PM130 PLUS
5.1 Configuring Communications
Explains how to configure serial and network communication ports for the PM130 PLUS.
5.2 General Meter Setup
Covers essential meter settings like wiring mode, nominal frequency, and load current.
5.3 Configuring Meter Security
Details how to set up user passwords and enable or disable password protection for the meter.
5.4 Configuring Billing/TOU
Describes how to configure billing registers, tariff rates, and TOU schedules for energy management.
Chapter 6 Device Control and Upgrading
6.1 Resetting Accumulators, Maximum Values and Files
Explains how to reset various data logs, counters, and accumulated values on the meter.
6.2 Updating the Meter Clock
Guides on how to set and synchronize the meter's internal clock.
6.3 Viewing and Clearing Device Diagnostics
Details how to view and clear diagnostic codes to monitor the meter's health.
6.4 Viewing Communication Status and Statistics
Explains how to check communication status and view statistics for GPRS and TCP clients.
6.5 Remote Relay Control
Describes how to send remote commands to operate or release relays on the meter.
6.6 Upgrading Device Firmware
Provides instructions on how to upgrade the meter's firmware using the PAS software.
Chapter 7 Monitoring Meters
7.1 Viewing Real-time Data
Explains how to retrieve and view live measurement data from the meter using PAS.
7.2 Viewing Real-time Min/Max Log
Guides on how to retrieve and view minimum and maximum logged values from the meter.
7.3 Viewing Real-time Waveforms
Details how to capture and view real-time voltage and current waveforms.
7.4 Viewing Real-time Harmonic Spectrum
Explains how to view harmonic spectrum data for voltage and current.
Chapter 8 Retrieving and Storing Files
8.1 Uploading Files on Demand
Describes how to manually retrieve log files from the meter using PAS.
8.2 Using the Upload Scheduler
Explains how to set up an automated schedule for uploading data from the meter.
8.3 Viewing Files On-line
Guides on how to view log data online without saving it to a file.
8.4 Exporting Files
Covers exporting data files in various formats like COMTRADE, PQDIF, and Excel.
8.5 Archiving Files
Explains how to archive data to manage large databases and maintain file performance.
Chapter 9 Viewing Files
9.1 Operations with Files
Details operations related to opening and saving database tables and files in PAS.
9.2 Viewing Options
Explains how to customize display options for dates, timestamps, and table views.
9.3 Viewing the Event Log
Guides on how to view and analyze the event log for configuration changes and diagnostics.
9.4 Viewing the Data Log
Explains how to view data log files in tabular or graphical trend formats.
Appendix A Technical Specifications
A.1 Environmental Conditions
Lists the environmental conditions for operating and storing the PM130 PLUS powermeter.
A.2 Construction
Provides details on the materials, dimensions, and construction of the PM130 PLUS unit.
A.3 Power Supply
Specifies the power supply options and ratings for the PM130 PLUS.
A.4 Input Ratings
Details the voltage and current input ratings and specifications for the PM130 PLUS.
A.5 Optional Relay Outputs
Describes the specifications for optional relay outputs, including electromechanical and solid-state types.
A.6 Optional Digital Inputs
Provides specifications for the optional digital input modules.
A.7 Optional Analog Outputs
Details the specifications for the optional analog output modules.
A.8 Communication Ports
Lists the available communication ports and their specifications (RS-485, Ethernet, Profibus, RS-232/422/485).
A.9 Real-time Clock
Provides specifications for the meter's real-time clock, including accuracy and retention time.
A.10 Display
Describes the display characteristics, including LED types and load bar graph modes.
A.11 Standards Compliance
Lists the standards and certifications the PM130 PLUS complies with for safety and performance.
A.12 Measurement Specifications
Details the accuracy and specifications for various measurements like voltage, current, power, and harmonics.

Table of Contents