Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Satec Manuals
Measuring Instruments
PM130E PLUS
Installation and operation manual
Satec PM130E PLUS Installation And Operation Manual
Powermeter
Hide thumbs
1
2
3
Table Of Contents
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
page
of
176
Go
/
176
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Chapter 1 General Information
Features
Available Options
Digital I/O
Analog Output
Additional Communication Port - COM2
TOU - Battery-Operated Clock Unit
Customized Options
Device Resolution
Energy Rollover
Display Options
Measured Parameters
Chapter 2 Installation
Site Requirements
Package Contents
Mechanical Installation
Panel Mounting
DIN Rail Mounting
Electrical Installation
Typical Installation
Terminals
Power Source Connection
Voltage Input Connection
Current Input Connection
Wiring Diagrams
DC Measurement
DC Voltage Measurement
DC Current Measurement (Hall Effect Sensors)
I/O Connections
4DI/2DO Module
DI Module
12DI/4RO Module
4AO Module - Analog Outputs
TOU Module - RTC and 4 Digital Inputs
Communications Connections
COM1 RS-485 Connection
ETH Module - COM2 Ethernet Connection
PRO Module - COM2 PROFIBUS Connection
RS-232/422-485 Module - COM2 Connection
Connecting a GSM/GPRS Modem
Connecting a Wifi Module
Chapter 3 Using Front Display
Indicators and Controls
Device Diagnostics
Numeric LED Display
Load Bar Graph AC Mode
Load Bar Graph DC Mode
Energy Pulse LED
Port Activity Leds
Navigation Buttons
Data Display
Display Features
Navigation Buttons
Simple Reset of Accumulated Data
Common Measurements Display
Common Measurements Display DC Mode
Min/Max and Maximum Demand Display
Min/Max and Maximum Demand Display DC Mode
Harmonics Display (PM130EH)
Energy Display (PM130E/EH)
Status Display
Pulse and Time Counters
Alarm Display
Diagnostics Display
Using the Menus
Navigation Buttons
Selecting Menus
Entering the Password
Selecting a Menu Entry
Viewing and Changing Setup Options
Chapter 4 Using PAS Software
Installing PAS
Creating a New Site for Your Meter
Setting up Communications
Communicating through a Serial Port
Communicating through the Internet
Setting up the Meter
Preparing Setups for the Meter
Downloading Setups to the Meter
Uploading Setups from the Meter
Authorization
Chapter 5 Configuring the PM130 PLUS
Configuring Communications
Setting up Serial Communication Ports
Setting up Ethernet
Setting up GPRS Network
Setting up Wifi Network
Setting up Expertpower Client
Setting up TCP Notification Client
General Meter Setup
Basic Meter Setup
Device Options
Configuring Digital Inputs
Configuring Relay Outputs
Configuring Analog Outputs
Configuring Counters
Configuring Alarm/Control Setpoints
Configuring the Display
Local Time Settings
Configuring Meter Security
Configuring Billing/Tou
Configuring Billing/Tariff Registers
Configuring the Daily Tariff Schedule
Configuring the Season Tariff Schedule
Configuring Recorders
Configuring Meter Memory
Configuring the Event Recorder
Configuring the Data Recorder
Configuring Communication Protocols
Configuring Modbus
Configuring DNP3
Configuring DNP Class 0 Responses
Chapter 6 Device Control and Upgrading
Resetting Accumulators, Maximum Values and Files
Updating the Meter Clock
Viewing and Clearing Device Diagnostics
Viewing Communication Status and Statistics
Remote Relay Control
Upgrading Device Firmware
Chapter 7 Monitoring Meters
Viewing Real-Time Data
Polling Devices
Organizing Data Sets
Polling Options
Viewing a Data Table
Viewing Data Trend
Saving Data to a File
Printing Data
Real-Time Data Logging
Viewing Real-Time Min/Max Log
Viewing Real-Time Waveforms
Viewing a Waveform Graph
Viewing a Frequency Plot
Viewing a Harmonic Spectrum
Viewing Phasor Diagrams
Viewing Symmetrical Components
Viewing Phase-To-Phase Voltages
Viewing Real-Time Harmonic Spectrum
Viewing a Spectrum Chart
Viewing a Spectrum Table
Viewing Synthesized Waveforms
Chapter 8 Retrieving and Storing Files
Uploading Files on Demand
Using the Upload Scheduler
Suspending the Scheduler
Running the Scheduler on Demand
Viewing Files On-Line
Exporting Files
Exporting Files in COMTRADE and PQDIF Formats
Manual Converting
Exporting Files in Excel Format
Archiving Files
Chapter 9 Viewing Files
Operations with Files
Opening a Database Table
Saving Data to a File
Viewing Options
Customizing Views
Working with Tables
Working with Graphic Windows
Viewing the Event Log
Viewing the Data Log
Appendix A Technical Specifications
Environmental Conditions
Construction
Power Supply
Input Ratings
Optional Relay Outputs
Optional Digital Inputs
Optional Analog Outputs
Communication Ports
Real-Time Clock
Display
Standards Compliance
Measurement Specifications
Appendix B Analog Output Parameters
Appendix C Setpoint Triggers and Actions
Appendix D Parameters for Data Monitoring and Logging
Appendix E Billing/Tou Profile Log File
Appendix F Data Scales
Appendix G Device Diagnostic Codes
Appendix H Summary Screen on Local Display for DC Mode
Appendix I Load Bar Graph for DC Current Mode
Advertisement
Quick Links
Download this manual
PM130 PLUS Powermeter Series
PM130P/PM130E/PM130EH
Installation and Operation Manual
BG0425 Rev. A21
PM130 PLUS Powermeter Series_Installation Operation and Manual
1
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the PM130E PLUS and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Satec PM130E PLUS
Measuring Instruments Satec PM130 PLUS Quick Start Manual
Multi-functional 3-phase power meter (4 pages)
Measuring Instruments Satec PM130 PLUS Installation And Operation Manual
Powermeter series (161 pages)
Measuring Instruments Satec PM130 PLUS Series Quick Start Manual
Powermeters (10 pages)
Measuring Instruments Satec PM130 PLUS Series Installation And Operation Manual
Powermeter (176 pages)
Measuring Instruments Satec PM130P Reference Manual
Pm130 plus series powermeters profibus dp communications protocol (32 pages)
Measuring Instruments Satec PM130P Installation And Operation Manual
Powermeters, series pm130 (55 pages)
Measuring Instruments Satec PM130EH SERIES Reference Manual
Powermeters communications modbus communications protocol (27 pages)
Measuring Instruments Satec PM130 Reference Manual
Powermeters (29 pages)
Measuring Instruments Satec PM130 series Reference Manual
Powermeters, ascii communications protocol (28 pages)
Measuring Instruments Satec PM130 Series Quick Start
Powermeter (4 pages)
Measuring Instruments Satec PM130P PLUS Installation And Operation Manual
Powermeter (176 pages)
Measuring Instruments Satec PM130EH PLUS Installation And Operation Manual
Powermeter (176 pages)
Measuring Instruments Satec PM135P Installation And Operation Manual
Pm135 powermeter series (167 pages)
Measuring Instruments Satec PM135E Installation And Operation Manual
Pm135 powermeter series (167 pages)
Measuring Instruments Satec PM135EH Installation And Operation Manual
Pm135 powermeter series (167 pages)
Measuring Instruments Satec PM172EH series Reference Manual
Powermeters, dnp3-2000 communications protocol (31 pages)
Summarization of Contents
WARNING
Chapter 1 General Information
1.1 Features
Lists the key features and capabilities of the PM130 PLUS powermeter series.
1.2 Available Options
Describes the optional expansion modules available for the PM130 PLUS, such as Digital I/O and communication ports.
1.3 Customized Options
Covers options for customizing data presentation and device behavior to suit specific applications.
1.4 Measured Parameters
Details the various parameters that the PM130 PLUS can measure and display.
Chapter 2 Installation
2.1 Site Requirements
Specifies the necessary environmental and electrical conditions for installing the PM130 PLUS powermeter.
2.2 Package Contents
Lists the items included in the PM130 PLUS powermeter package.
2.3 Mechanical Installation
Provides instructions and dimensions for the physical mounting of the PM130 PLUS unit.
2.4 Electrical Installation
Details the electrical connections and wiring procedures for the PM130 PLUS powermeter.
2.5 DC Measurement
Explains how to perform DC voltage and current measurements using the PM130 PLUS.
2.6 I/O Connections
Describes how to connect Digital Inputs and Relay Outputs using optional I/O modules.
2.7 Communications Connections
Covers the setup and connection of communication ports like RS-485, Ethernet, GPRS, and WiFi.
Chapter 3 Using Front Display
3.1 Indicators and Controls
Identifies and explains the various indicators, buttons, and display elements on the PM130 PLUS front panel.
3.2 Data Display
Details how measurement data is displayed on the PM130 PLUS, including units and features.
3.3 Status Display
Explains how to access and interpret the meter's status information, useful for troubleshooting.
3.4 Using the Menus
Guides the user on navigating through the meter's menu system for configuration and setup.
Chapter 4 Using PAS Software
4.1 Installing PAS
Provides step-by-step instructions for installing the PAS software on a PC.
4.2 Creating a New Site for your Meter
Explains how to create a new site database in PAS for managing meter configurations.
4.3 Setting up Communications
Details how to establish communication between the PAS software and the PM130 PLUS meter.
4.4 Setting Up the Meter
Guides users on preparing and downloading meter configurations using the PAS software.
4.5 Authorization
Covers the authorization process required when sending setup data to a secured meter.
Chapter 5 Configuring the PM130 PLUS
5.1 Configuring Communications
Explains how to configure serial and network communication ports for the PM130 PLUS.
5.2 General Meter Setup
Covers essential meter settings like wiring mode, nominal frequency, and load current.
5.3 Configuring Meter Security
Details how to set up user passwords and enable or disable password protection for the meter.
5.4 Configuring Billing/TOU
Describes how to configure billing registers, tariff rates, and TOU schedules for energy management.
Chapter 6 Device Control and Upgrading
6.1 Resetting Accumulators, Maximum Values and Files
Explains how to reset various data logs, counters, and accumulated values on the meter.
6.2 Updating the Meter Clock
Guides on how to set and synchronize the meter's internal clock.
6.3 Viewing and Clearing Device Diagnostics
Details how to view and clear diagnostic codes to monitor the meter's health.
6.4 Viewing Communication Status and Statistics
Explains how to check communication status and view statistics for GPRS and TCP clients.
6.5 Remote Relay Control
Describes how to send remote commands to operate or release relays on the meter.
6.6 Upgrading Device Firmware
Provides instructions on how to upgrade the meter's firmware using the PAS software.
Chapter 7 Monitoring Meters
7.1 Viewing Real-time Data
Explains how to retrieve and view live measurement data from the meter using PAS.
7.2 Viewing Real-time Min/Max Log
Guides on how to retrieve and view minimum and maximum logged values from the meter.
7.3 Viewing Real-time Waveforms
Details how to capture and view real-time voltage and current waveforms.
7.4 Viewing Real-time Harmonic Spectrum
Explains how to view harmonic spectrum data for voltage and current.
Chapter 8 Retrieving and Storing Files
8.1 Uploading Files on Demand
Describes how to manually retrieve log files from the meter using PAS.
8.2 Using the Upload Scheduler
Explains how to set up an automated schedule for uploading data from the meter.
8.3 Viewing Files On-line
Guides on how to view log data online without saving it to a file.
8.4 Exporting Files
Covers exporting data files in various formats like COMTRADE, PQDIF, and Excel.
8.5 Archiving Files
Explains how to archive data to manage large databases and maintain file performance.
Chapter 9 Viewing Files
9.1 Operations with Files
Details operations related to opening and saving database tables and files in PAS.
9.2 Viewing Options
Explains how to customize display options for dates, timestamps, and table views.
9.3 Viewing the Event Log
Guides on how to view and analyze the event log for configuration changes and diagnostics.
9.4 Viewing the Data Log
Explains how to view data log files in tabular or graphical trend formats.
Appendix A Technical Specifications
A.1 Environmental Conditions
Lists the environmental conditions for operating and storing the PM130 PLUS powermeter.
A.2 Construction
Provides details on the materials, dimensions, and construction of the PM130 PLUS unit.
A.3 Power Supply
Specifies the power supply options and ratings for the PM130 PLUS.
A.4 Input Ratings
Details the voltage and current input ratings and specifications for the PM130 PLUS.
A.5 Optional Relay Outputs
Describes the specifications for optional relay outputs, including electromechanical and solid-state types.
A.6 Optional Digital Inputs
Provides specifications for the optional digital input modules.
A.7 Optional Analog Outputs
Details the specifications for the optional analog output modules.
A.8 Communication Ports
Lists the available communication ports and their specifications (RS-485, Ethernet, Profibus, RS-232/422/485).
A.9 Real-time Clock
Provides specifications for the meter's real-time clock, including accuracy and retention time.
A.10 Display
Describes the display characteristics, including LED types and load bar graph modes.
A.11 Standards Compliance
Lists the standards and certifications the PM130 PLUS complies with for safety and performance.
A.12 Measurement Specifications
Details the accuracy and specifications for various measurements like voltage, current, power, and harmonics.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the PM130E PLUS and is the answer not in the manual?
Questions and answers