PDK A8 Quick Start Manual

Aux eight controller

Advertisement

Quick Start Guide
View the user manual here:
www.prodatakey.zendesk.com
PN : A8
www.prodatakey.com
801.317.8802
Copyright © 2023 ProdataKey Inc. All rights reserved. Pdk, Pdk io, and
the Red logos are trademarks of ProdataKey Inc.
REV 03082023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A8 and is the answer not in the manual?

Questions and answers

Summary of Contents for PDK A8

  • Page 1 Quick Start Guide View the user manual here: www.prodatakey.zendesk.com PN : A8 www.prodatakey.com 801.317.8802 Copyright © 2023 ProdataKey Inc. All rights reserved. Pdk, Pdk io, and the Red logos are trademarks of ProdataKey Inc. REV 03082023...
  • Page 2: Package Contents

    1. Package Contents Battery Leads (1) Jumpers (8) Red Aux 8 Auxiliary Controller (1) Can Lock (1) Transformer (1) 14 VDC, 5 Amp Diodes (8)
  • Page 3 2. Elevator Floors POWER HEART LINK Elevator Control Panel 12-24VDC Elevator Control Panel - Wire each floor trigger to the Aux 8 relay ports using an 18/2 wire. Common - Connect one wire from the elevator control panel into common on the relay input.
  • Page 4 Select the floors that will be accessible for all members of the group Save the Group Assigning Permission to Floors Add permissions within People or Groups within pdk.io Create a new Rule for a person or group Click on the tab titled “elevator”...
  • Page 5: Input Connection

    Examples include door position sensors and push buttons. Aux input - The input reports in pdk.io as a DPS (A) input. When initiated, a rule can be set up to trigger events or outputs based on this input trigger...
  • Page 6 5. Wet Contact Output POWER HEART Piezo Alarm LINK 12-24VDC Aux Device - An Aux device can be connected to the door controller to be triggered based on specific events in the system. The most typical trigger is a door prop alarm. Connect the device as shown above. Jumper Block(s) Use to designate (+) or (-) board voltage out of NO and NC.
  • Page 7 6. Dry Contact Output POWER HEART LINK Aux Device alarm panel, lighting HVAC, etc. 12-24VDC Device - A variety of devices can be wired into any of the Aux 8’s relay ports to trigger a specific action. Examples include alarm panel integration, lighting, and HVAC.
  • Page 8: Communication Connection

    Ethernet - All Red controllers come with a built-in RJ45 connection for network connectivity. Once connected the Red controller is Self-Discoverable from pdk.io using IPV6. Alternatively, you may use IPV4 or assign a static IP using pdk.io if desired. POWER...
  • Page 9: Power Connection

    8. Power Connection 12-24VDC t t e DC Input - Input 12-24 VDC power using an 18/2 wire. For high voltage applications, use the High Voltage Converter (PN: HVC) Backup Battery - The enclosure will fit most 12V 8 Ah batteries. Connect the battery to the controller using the supplied battery leads.
  • Page 10: Reference Guide

    For UL-listed installations, all cable runs must be less than 30 meters (98.5’) Amperage Limits - The Aux 8 delivers an amperage limit of 4 amps for all electrified hardware plugged into the board Part Number - A8 PDK Technical Support Phone: 801.317.8802 option #2 Email: support@prodatakey.com...