n Error messages
When multiple amplifiers are connected by F.C.B.S., the error
messages described in the table below may be displayed on
the display. In such a case, ID number setting or remote cable
connection may be in failure. Check the ID number or remote
cable connection, referring to the table below. For details on
ID number setting, see "How to set ID number for F.C.B.S."
(vpage 15).
Indication
Meaning
1
ERROR 02
Multiple amplifiers take ID No. 2.
2
ERROR 03
Multiple amplifiers take ID No. 3.
3
ERROR 04
Multiple amplifiers take ID No. 4.
! Assign different ID numbers to the amplifiers.
4
ERROR 11
The amplifiers with ID Nos. 2-4 cannot
communicate with the amplifier with ID
No. 1.
! If the amplifier with ID No. 1 is not on, turn it ON.
! Check that the remote cable is properly connected.
5
ERROR 12
The amplifier with ID No. 1 cannot
communicate with the amplifiers with ID
Nos. 2-4.
! If multiple amplifiers take ID No. 1, set ID numbers
properly.
! If the amplifier with ID No. 1 is connected to the amplifier
with ID No. 0, set ID numbers properly.
! Check that the remote cable is properly connected.
22
n Are the connections correct?
n Is the unit being operated as described in the owner's manual?
n Are the other components operating properly?
If this unit does not operate properly, check the items listed in the table below. If the problem persist there may be a malfunction.
In that case, disconnect the power immediately and contact your retail outlet.
Symptom
When the power is turned
• The power cord's plug is not fully
on, the power indicator does
plugged in.
not light and no sound is
produced.
Power switches off suddenly
• The protection circuit will be activated
while you are using the unit,
depending upon the temperature rise in
the
power
indicator
will
the internal parts of the unit.
flash in red at intervals of
approximately 2 seconds.
Power switches off suddenly
• A
speaker
while you are using the
supported by this unit is used.
unit, the power indicator
• The protection circuit has been activated
will flash red at intervals of
because the core wires of different
approximately 0.5 seconds.
speaker cables have touched each other
or a core wire was slipped out of the
terminal and is touching the unit's rear
panel.
Even applying power, the
• The amplifier circuit in failure.
power display flashes red at
intervals of approximately 0.5
seconds.
The power indicator lights
• The speaker cables are not fully
but no sound is produced.
connected.
• The device you want to listen to has not
been selected.
• The volume control is set to minimum.
• The input cable is not fully connected.
• The speaker output switch is set to OFF.
Sound is only produced from
• The speaker cables are not fully
the left or right speaker (s).
connected.
• The input cable is not fully connected.
• The left/right balance is off.
Cause
Countermeasure
• Check the cord is securely inserted into
the unit's AC inlet and the wall power
outlet.
• Please switch off power at once, and
re-apply the power after the body
temperature has fallen sufficiently.
• Please re-install the unit in a place
having good ventilation.
with
impedance
not
• Please use speakers which have the
specified impedance.
• Unplug the power cord, then after
twisting
the
tightly again, or effecting termination
treatments etc, please reconnect once
again.
• Switch off the power and please contact
the marantz service adviser.
• Connect securely.
• Insure the correct input is selected.
• Set to an appropriate level.
• Connect securely.
• Set the speaker output switch to ON.
• Connect securely.
• Connect securely.
• Adjust to a proper balance with the
balance control knob.
Troubleshooting
Page
10
7
2
7
7
core
wires
together
7
11
11
9
11
7
9
12