ZCS AZZURRO 1PH HYD6000-ZP1 User Manual

ZCS AZZURRO 1PH HYD6000-ZP1 User Manual

Single-phase hybrid storage inverter
Table of Contents

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZZURRO 1PH HYD6000-ZP1 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Preface
Overview and Safety Symbols
Covers manual scope, recipients, and explains safety instruction symbols.
Introduction
System Overview and Features
Describes the hybrid inverter system and its main features.
Product Model Description
Details on inverter model identifiers and their specifications.
Product Capacity Description
Explains system expansion and parallel inverter support.
Product Appearance Overview
Visual overview of the inverter's front and back sides with component labels.
Inverter Port Diagram
Identifies and describes the various ports on the inverter's side panels.
Battery Module Port Diagram
Details the ports on the battery module's left and right sides.
Installation and Maintenance Requirements
General Installation and Safety Guidelines
Emphasizes manual reading, standards compliance, and crucial safety notes.
Assembly, Maintenance, and Transportation Precautions
Guidelines on battery handling, ventilation, tool usage, safety, and transport requirements.
Electrical Connection Safety and Cautions
Safety precautions for electrical connections and operational/maintenance cautions.
EMC, Symbols, and Inverter Module Symbols
Covers EMC, general safety symbols, and inverter module safety symbols.
Installation
Pre-installation Checks and Packaging Contents
Verifying package integrity, model accuracy, and listing all included accessories.
Installation Environment and Tool Requirements
Specifies installation location conditions and lists necessary installation tools.
Installation Position and Space Guidelines
Recommends vertical mounting, protection, and details necessary clearances around the unit.
Product Installation Diagram
Illustrates installation dimensions and component placement for the system.
Pedestal Installation Procedure
Step-by-step guide for mounting the pedestal to the wall or ground.
Module Installation Procedure
Instructions for connecting and installing battery modules and inverters sequentially.
Support Rack Installation Procedure
Steps for installing the wall support rack for the inverter and battery modules.
Electrical Connections
Pre-Connection Cautions and Safety
Important safety warnings regarding high voltage, chemical hazards, and proper PPE.
Connection Cable Preparation
Specifies recommended cable types and specifications for system connections.
Internal System Electrical Connection
Internal Grounding Cable Connection (up to 3 Batteries)
Illustrates how to connect internal protection grounding cables for up to three batteries.
Internal DC Power Cable Connection (up to 3 Batteries)
Details connecting DC power cables between the inverter and battery modules.
Internal Communication Cable Connection (up to 3 Batteries)
Explains how to connect internal communication cables between modules.
Configuration for Up to 3 Batteries
Guide to configuring inverter channels and battery parameters for systems up to 3 batteries.
Internal Grounding for 4 Batteries
Shows grounding cable connections for systems with four batteries.
Internal DC Power Cables for 4 Batteries
Details DC power cable connections for systems with four batteries.
Internal Communication Cables for 4 Batteries
Explains communication cable connections for systems with four batteries.
Configuration for 4 Batteries
Guide to configuring inverter channels and battery parameters for systems with four batteries.
Data Collector Connection
Instructions for connecting the Wi-Fi/4G data collector to the inverter.
External Electrical Connections
External Grounding Connection (PGND Cable)
Step-by-step guide for crimping and connecting the external grounding wire.
Grid Connection Wiring
Instructions for preparing and installing AC wiring terminals for grid connection.
Critical Load (EPS Function) Connection
Details on connecting critical loads using the EPS output and change-over switch.
Photovoltaic Connection Procedure
Steps for preparing and connecting DC input cables for PV arrays.
Inverter Channel Configuration for PV Input
Guide to configuring inverter channels for PV input modes (independent/parallel strings).
COM Port Communication Details
Details the COM port pin definitions and functions for multi-function communication.
Link Port Connections and Settings
Explains the Link Port diagram, define, function, and dip switch settings.
RS485 Communication Setup
Instructions for connecting RS485 for wired or cascade monitoring.
Logic Interface Connections
Details logic interface pin definitions and circuit connections for DRMs and RRCR.
Current Transformer (CT) Connection
Guidelines for using CTs for grid current information.
Single-Phase DDSU Meter Connection
Instructions for connecting a single-phase DDSU meter for exchange readings.
Three-Phase DTSU Meter Connection
Instructions for connecting a three-phase DTSU meter for exchange and production readings.
Measuring Exchange with Single-Phase DDSU Meter
Details connecting and configuring the DDSU meter for exchange measurements.
Measuring External Production with DDSU Meter
Guide to measuring external production using a CHINT DDSU meter.
Setting Up Exchange and Production Meters
Explains how to set up DDSU meters for exchange and external production readings.
Verifying DDSU Single-Phase Meter Readings
Steps to verify correct readings on the DDSU single-phase meter for exchange.
Three-Phase DTSU Meter Connection to Exchange
Details connecting the three-phase DTSU meter for exchange and production.
PV Production Measurement with Three-Phase DTSU Meter
Explains measuring PV production using a second DTSU Meter.
Three-Phase DTSU Meter Parameter Configuration
Step-by-step guide to configure DTSU meter parameters for exchange.
DTSU Three-Phase Meter Installation Verification
Procedures for verifying correct installation of DTSU meters at exchange and production.
Exchange Measurement via Current Sensor
How to connect and position current sensors for measuring grid exchange.
Installing the Protective Cover
Instructions for installing the external protective cover after connections are complete.
Buttons and Indicator Lights
Inverter Buttons Overview
Describes the function of each button on the inverter interface.
System Status Indicators
Explains the meaning of the blue, green, and red indicator lights for system status.
Battery Capacity Indicator Guide
Illustrates battery capacity levels and their corresponding explanations.
System Electrical Topology
General and Australian Topology Diagrams
Illustrates overall system connections and Australian version topology.
Operation
Preliminary Checks Before Operation
Checklist for ensuring secure installation and correct connections before system startup.
Initial Inverter Startup and Parameter Configuration
Steps for first startup, AC switch settings, and parameter configuration.
Basic Settings: Safety Parameters and Defaults
Lists default settings for modes and notes on selecting the correct country code.
Commissioning and Main Interface Overview
Details commissioning process and describes the inverter's main interface display.
Main Menu Navigation
Explains how to navigate the main interface and access different menu options.
Basic Settings Configuration (Language, Time, Storage)
Guide to setting language, time, and energy storage mode.
Energy Storage and Time-of-Use Modes
Explains automatic, time-of-use modes for battery charge/discharge.
Timing and Passive Modes Configuration
Details timing modes for charging and passive mode for inverter testing.
Photovoltaic Input and EPS Mode Settings
How to select PV input modes and enable EPS output for critical loads.
Communication Address and Self-Test Procedures
How to set RS485 address and perform inverter self-tests.
Advanced Self-Test and Calibration Settings
Covers PF Time Setting, QV Time Setting, and Control 81.S1 options for testing.
Advanced Settings: Battery Parameters
Configuration for battery type, quantity, charge/discharge limits.
Advanced Settings: Battery Activation, Reflux, IV Scan
Settings for battery activation, anti-reflux control, and IV curve scanning.
Advanced Settings: Logic Interface and Factory Reset
Options for logical interface control and factory reset of the inverter.
Advanced Settings: Parallel, Bluetooth, CT, Meter
Configuration for parallel systems, Bluetooth reset, CT calibration, and electricity meter.
Advanced Settings: Off-Grid Grounding
Setting options for off-grid grounding configuration.
Energy Statistics Monitoring
How to view daily, monthly, and yearly energy production and consumption data.
System Information Display
Details on how to access and interpret inverter information like serial number, firmware, and settings.
Event List Access
How to view lists of current and historical events and alarms.
Software Update Procedure
Step-by-step guide for updating inverter firmware using a USB drive.
Functional Verification Steps
Procedures to check the proper functioning of the inverter after installation.
Troubleshooting
General Troubleshooting and Error Codes
Guides on checking installation and viewing error codes for fault diagnosis.
Maintenance
General Maintenance and Battery Storage
Instructions for cleaning the inverter and proper storage of battery modules.
Battery Storage and Recharge Requirements
Guidelines for recharging batteries during normal storage and when over-discharged.
Uninstalling and Disposal
Uninstallation, Packaging, Storage, and Disposal
Steps for uninstalling, repacking, storing, and disposing of the inverter.
Monitoring Systems
External Wi-Fi Adapter Installation
Guide for installing an external Wi-Fi adapter for inverter monitoring.
External Wi-Fi Adapter Configuration
Steps to configure the Wi-Fi adapter for stable data transmission.
Wi-Fi Adapter Troubleshooting
Common issues and solutions for irregular communication with the Wi-Fi adapter.
Ethernet Adapter Installation
Guide for installing the Ethernet adapter for inverter monitoring.
Ethernet Adapter Verification
Checks the status of LEDs on the Ethernet adapter after installation.
Ethernet Adapter Troubleshooting
Common issues and solutions for irregular communication with the Ethernet adapter.
4G Adapter Installation
Guide for installing the 4G adapter for inverter monitoring.
4G Adapter Verification
Checks the status of LEDs on the 4G adapter after installation.
4G Adapter Troubleshooting
Common issues and solutions for irregular communication with the 4G adapter.
Datalogger Configuration Overview
Introduces datalogger options and preliminary notes for configuration.
Datalogger Electrical Connections and Configuration
Details electrical connections and RJ45 pinouts for datalogger setup.
Datalogger Wi-Fi Configuration
Guide to configuring the datalogger via Wi-Fi using a smartphone or PC.
Verifying Datalogger Configuration Status
Checks LED status and connection details to confirm datalogger setup.
ZSM-RMS Datalogger Description and Interface
Details the physical description and ports of ZSM-RMS001/M200/M1000 dataloggers.
Connecting Datalogger to Inverters via RS485
Instructions for connecting dataloggers to inverters using RS485 serial communication.
Datalogger Connections and Setup
Guides for Ethernet connection, power supply, battery pack, and sensor connections.
Configuring Datalogger on ZCS Azzurro Portal
Steps to register and configure the datalogger on the ZCS Azzurro web portal.
Local Monitoring Requirements
Requirements for installing and setting up local monitoring on the datalogger.
Local Monitoring Features
Explains features of local monitoring, including parameter display and alarm viewing.

Table of Contents

Save PDF