Comfort Glow CDVBN(A), CDVBP(A) Owner's Operation And Installation Manual page 16

Cast iron stove and direct-vent (freestanding fireplace heater) burner system
Table of Contents

Advertisement

CAST IRON STOVE AND BURNER SYSTEM
VENTING
INSTALLATION
Continued
Vertical Termination
Configurations
Figures 34 through 36 and Figure 37 on
page 17 show four different configurations
for vertical termination. All connections
must be sealed with high temperature sili-
cone sealant as specified in the second warn-
ing statement on page 10.
Note: Install restrictor
into 4" collar of burner
system as shown.
Venting with One 90 Elbow
Vertical (V)
Horizontal (H)
5' min.
6' min.
7' min.
8' min.
20' max.
Figure 34 - Vertical Rigid Venting
Configuration Using One 90 Elbow
CDVBN(A) AND CDVBP(A)
Figure 35 - Vertical Rigid Venting Configuration Using Two 90 Elbows with Two
Horizontal Runs
2' max.
4' max.
6' max.
8' max.
8' max.
Figure 36 - Vertical Rigid Venting Configuration Using Two 90 Elbows
Note: Install
restrictor into 4"
collar of burner
system as shown.
Venting with Two 90 Elbows
Vertical (V
5' min.
6' min.
7' min.
8' min.
Note: Install restrictor
into 4" collar of burner
system as shown.
16
Venting with Two 90 Elbows
Vertical (V)
Horizontal (H
Horizontal (H
5' min.
2' max.
6' min.
4' max.
7' min.
6' max.
8' min.
8' max.
20' max.
8' max.
)
Horizontal (H)
1
6' max.
12' max.
18' max.
20' max.
Note: Vertical (V
Vertical (V
) = 20' max.
2
) +
1
)
2
) +
1
105501

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

CdvbnCdvbp

Table of Contents