INSTALLATION
Continued
For Built-In Installation
WARNING: A licensed elec-
trician must connect the wiring
harness to electrical supply
following all local codes. Electri-
cian must provide a clamp on the
box cover to secure the wiring.
Wiring should be routed through
the bushing in the hole on the
outer casing of fireplace.
1. Install snap bushing from blower kit into
one hole on rear of remote/blower bracket
(see Figure 17). The other hole is for a strain
relief clamp (not supplied) to secure incoming
electrical supply.
2. Follow steps 2 through 6 in Installing Blower
Accessory, page 14.
3. A licensed electrician must follow the wiring
diagram to connect incoming electrical supply
to fan kit wiring harness (see Figure 18).
4. Plug power cord to outlet receptacle (not
provided) as shown in Figure 18. Wind extra
cable of power cord and tie up with plastic
wire strap (see Figure 17). Set cable bundle
between the remote/blower bracket and outer
casing, away from the burner.
Blower Bracket
Assembly
Screw
Power Cord
Switch
3
2
1
Switch
Plate
116658-01A
Wire Harness
www.desatech.com
5. Test to make sure blower is working properly.
6. Reinstall upper louver beginning with bottom
screws (see Figure 11, page 12) and close
lower louver.