CDR System Messages

CDR-1001
Message
<timestamp>, [CDR-1001], <sequence-number>,, ERROR, <system-name>, Port
number>
Probable Cause
Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, a faulty cable
between peer ports, or that the port speed configuration does not match the capability of the SFP.
Recommended
Ensure that you are using compatible SFPs on the peer ports.
Action
Verify whether the SFPs have deteriorated or the Fibre Channel cable is faulty. Replace the SFPs or
cable, if necessary.
Severity
ERROR
CDR-1002
Message
<timestamp>, [CDR-1002], <sequence-number>, FFDC, ERROR, <system-name>, Port
<port number>
Probable Cause
Indicates an internal error.
Recommended
For a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade to recover
Action
the system. For a non-bladed system, perform fastBoot command on the switch to recover the
system.
Severity
ERROR
CDR-1003
Message
<timestamp>, [CDR-1003], <sequence-number>, FFDC, CRITICAL, <system-name>, <slot
number>, <chip index> HW ASIC chip error type =0<chip error type>
Probable Cause
Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may
degrade data traffic.
Recommended
Whenever this error occurs, restart the system at the next maintenance window. If the problem
Action
persists, replace the blade.
Fabric OS Message Reference
53-1001338-01
port fault. Please change the SFP or check cable
chip faulted due to internal error.