FSSM-1004
Probable Cause
Indicates that the active control processor (CP) and the standby CP in a dual CP system are running
firmware that are incompatible with each other. If the active CP fails, the failover will be disruptive.
In a switch system, this message is logged when a firmware upgrade or downgrade was invoked.
The new firmware version is not compatiable with the current running version. This causes a
disruptive firmware upgrade or downgrade.
Recommended
For a dual CP system, run the firmwareDownload command to load compatible firmware on the
Action
standby CP. For details on this command, refer to the Fabric OS Command Reference Manual.
Severity
INFO