McDATA StorageWorks 64 - SAN Director Switch Planning Manual page 158

Fw 07.00.00/hafm sw 08.06.00 mcdata products in a san environment planning manual (620-000124-500, april 2005)
Hide thumbs Also See for StorageWorks 64 - SAN Director Switch:
Table of Contents

Advertisement

Implementing SAN Internetworking Solutions
4
McDATA Products in a SAN Environment - Planning Manual
4-14
For attached fabrics in which participating element's Interop Mode is
set to McDATA Fabric 1.0, Domain_IDs of 30 and 31 are recognized
by SAN management applications and all attached devices. For
attached fabrics in which participating element's Interop Mode is set to
Open Fabric 1.0, Domain_IDs of 30 and 31 are recognized by SAN
management applications. Domain_IDs of 7E and 7F are recognized
by all attached devices.
As shown in
Figure 4-5
fabric 1 appears as follows:
One Fibre Channel switch (Domain_ID 6) with direct-attached
devices D
and D
.
1
2
One edge switch (Domain_ID 1) that represents an R_Port.
One virtual switch (Domain_ID 30) that represents a routing
domain with devices D
devices are physically connected to Fabric 2.
One virtual switch (Domain_ID 31) that represents a routing
domain with device D
physically connected to the router.
As shown in
Figure 4-5
fabric 2 appears as follows:
One Fibre Channel director (Domain_ID 7) with direct-attached
devices D
and D
.
3
4
One Fibre Channel switch (Domain_ID 8) with direct-attached
devices D
and D
.
5
6
One edge switch (Domain_ID 2) that represents an R_Port.
One virtual switch (Domain_ID 30) that represents a routing
domain with devices D
are physically connected to Fabric 1.
One virtual switch (Domain_ID 31) that represents a routing
domain with device D
physically connected to the router.
Routing domains represent devices from remote fabrics and are a key
part of SAN routing. The routing domain with Domain_ID 30 enables
routing between multiple fabrics (mSAN routing). The routing
domain with Domain_ID 31 enables routing between multiple
mSANs (iSAN routing). Refer to
additional information.
from a logical connectivity perspective,
, D
, D
, and D
logically attached. These
3
4
5
6
logically attached. This device is
7
from a logical connectivity perspective,
and D
logically attached. These devices
1
2
logically attached. This device is
7
mSAN Routing
or
iSAN Routing
for

Advertisement

Table of Contents
loading

Related Products for McDATA StorageWorks 64 - SAN Director Switch

This manual is also suitable for:

316095-b21 - storageworks edge switch 2/24Storageworks 2/140 - director switchStorageworks 2/24 - edge switchStorageworks 2/12 - edge switch316095-b21 - storageworks edge switch 2/24Storageworks 2/140 - director switch ... Show all

Table of Contents