3.3.3
Fault Tolerance
Table 8
shows the Intel
Table 8.
Support for SMART
Optional Battery Backup for Cache Memory
Drive Failure Detection
Drive Rebuild Using Hot Spares
Parity Generation and Checking
a. The Self Monitoring Analysis and Reporting Technology (SMART) detects up to 70 percent of
all predictable disk drive failures. SMART also monitors the internal performance of all motors,
heads, and drive electronics.
3.3.4
Electrical Characteristics
This section provides the power requirements for the Intel
lists the maximum power requirements, which include SCSI TERMPWR, under normal operation.
Table 9.
Storage
Adapter
320-1
3.3.5
Thermal and Atmospheric Characteristics
For all Intel
•
relative humidity range: 5% to 90% noncondensing
maximum dew point temperature: 32 °C
•
•
airflow must be at least 300 lfm to keep the LSI53C1020 and LSI53C1030 heat sink
temperature below 80 °C
The following parameters define the storage and transit environment for the Intel
SRCU41L
temperature range: − 40 °C to + 105 °C (dry bulb)
•
•
relative humidity range: 5% to 90% noncondensing
®
Intel
Raid Controller SRCU41L User Manual
®
Raid Controller SRCU41L fault tolerance features.
®
Intel
Raid Controller SRCU41L Fault Tolerance Features
Specification
a
Maximum Power Requirements
PCI/PCI-X/
PCI/PCI-X +5.0
Express +12 V
115 mA; used
only if battery is
1.5 A (PCI only)
present
®
Raid Controller SRCU41Ls, the thermal and atmospheric characteristics are
Storage Adapter Characteristics
Intel
Yes
3.6 V/600mAH battery pack. Up to 48 hours data
retention for
64 MB.
Automatic
Automatic
Yes
®
Raid Controller SRCU41Ls.
PCI/PCI-X/
V
Express+3.3 V
N/A
®
Raid Controller SRCU41L
Table 9
PCI PRSNT1#/
Over the
PRSNT2#
Operating
Power
Range
15 W
0 °C to 55 °C
®
Raid Controller
17