Fault Tolerance; Table 4. Fault Tolerance Features - Intel SROMBSASMR Hardware User's Manual

Integrated raid module
Hide thumbs Also See for SROMBSASMR:
Table of Contents

Advertisement

Host data transfer rate
Maximum queue tags per
drive
Stripe sizes
Maximum concurrent
commands
Support for multiple initiators
Performance
Flexibility
Background services
Cache options

Fault Tolerance

Self Monitoring Analysis and
Reporting Technology (SMART)
support
Optional Battery Backup
Drive Replacement
Drive Rebuild Using Hot Spares
Error Checking and Indication
Intel® Integrated RAID Module SROMBSASMR Hardware User's Guide
Specification
2.5 Gigabit/sec per PCI Express* lane
As many as the drive can accept
8, 16, 32, 64, 128, 256, 512, or 1024 KB
255
Yes
Native command queuing
Drive migration, RAID level migration, Drive Roaming, Online
Capacity Expansion - without reboot
Rebuild, Consistency Check, Migration, OCE, and Patrol Read
Write-back or Write-through; Read Ahead, Adaptive Read
Ahead, Non Read Ahead; Cache I/O or Direct I/O; Disk Cache

Table 4. Fault Tolerance Features

Specification
®
Intel
Integrated RAID Module SROMBSASMR
®
Intel
Integrated RAID Module SROMBSASMR
Detects up to 70% of predictable disk drive failures
Monitors the internal performance of all motors, heads,
and drive electronics.
®
Intel
RAID Smart Battery AXXRSBBU3 cache backup
Up to 72 hours of data retention
Auto detection of failure
Hot-plug
Hot-swap
Automatic at fail
Dedicated per Array
Global for any array
Auto-resume of initialization or rebuild on reboot
Parity generation and checking, automatic consistency
checking
Patrol reads
Activity and fault LEDs
Multiple retries
Logs in NVRAM, event log, CIM, Smart, Intel
Web Console 2
®
RAID
15