If you want to run the Intel
this point, press the appropriate keys when this message appears:
Press <CTRL><G> for WebBIOS
2.3.1
Resolving a Configuration Mismatch
If the replacement controller has a previous configuration, a message displays during the power-on
self test (POST) stating that there is a configuration mismatch. A configuration mismatch occurs
when the configuration data in the NVRAM and the hard disk drives are different. You need to
update the configuration data in the NVRAM with the data from the hard disk drive.
Perform the following steps to resolve the mismatch.
1. Press <Ctrl> <G> when prompted during bootup to access the BIOS Configuration Utility.
2. Select Configure—> View/Add Configuration.
This gives you the option to view both the configuration on the NVRAM and the hard drive
disk.
3. Select the configuration on disk.
4. Press <ESC> and select YES to update NVRAM.
5. Exit and reboot.
2.4
After You Have Installed the Storage Adapter
After Intel
SRCU41L and install the operating system driver. The Software User's Guide instructs you on the
configuration options and how to set them on your Intel
User's Guide also provides detailed installation instructions for operating system drivers.
®
Intel
SRCU41L Raid Controller User Manual
®
Raid Controller SRCU41L Configuration utility or BIOS Console at
®
Raid Controller SRCU41L installation, you must configure the Intel
Hardware Installation
®
®
Raid Controller SRCU41L. The Software
Raid Controller
11
Need help?
Do you have a question about the SRCU41L - RAID Controller and is the answer not in the manual?
Questions and answers