CAUTION:
corresponding LEDs on other drives in the array are active, the rebuild process has abnormally
terminated. The amber Fault LED of one or more drives might also be illuminated. Refer to
"Abnormal termination of a rebuild (on page 37)" to determine what action you must take.
Abnormal termination of a rebuild
If the Online/Activity LED on the replacement drive permanently ceases to be illuminated even while other
drives in the array are active, the rebuild process has abnormally terminated. The following table
indicates the three possible causes of abnormal termination of a rebuild.
Observation
None of the drives in the array have
an illuminated amber Fault LED.
The replacement drive has an
illuminated amber Fault LED.
One of the other drives in the array
has an illuminated amber Fault LED.
Each of these situations requires a different remedial action.
Case 1: An uncorrectable read error has occurred.
Back up as much data as possible from the logical drive.
1.
CAUTION:
to fail.
Restore data from backup. Writing data to the location of the unreadable sector often eliminates the
2.
error.
Remove and reinsert the replacement drive. This action restarts the rebuild process.
3.
If the rebuild process still terminates abnormally:
Delete and recreate the logical drive.
1.
Restore data from backup.
2.
Case 2: The replacement drive has failed.
Verify that the replacement drive is of the correct capacity and is a supported model. If these factors are
not the cause of the problem, use a different drive as the replacement.
Case 3: Another drive in the array has failed.
A drive that has recently failed can sometimes be made temporarily operational again by cycling the
server power.
Power down the server.
1.
Remove the replacement physical drive (the one undergoing a rebuild), and reinstall the drive that it
2.
is replacing.
Power up the server.
3.
If the newly failed drive seems to be operational again:
Back up any unsaved data.
1.
If the Online/Activity LED on the replacement drive does not light up while the
Cause of rebuild termination
One of the drives in the array has
experienced an uncorrectable read error.
The replacement drive has failed.
The drive with the illuminated Fault LED has
now failed.
Do not remove the drive that has the media error. Doing so causes the logical drive
Replacing, moving, or adding hard drives 37