3.3.2
Electrical Characteristics
Table 3-3 lists the maximum power requirements for the RAID Controller SRCS16 under
normal operation.
Table 3-3
RAID Controller
SRCS16
(load sharing enabled)
SRCS16
(load sharing disabled)
1. The total power for the SRCS16 has taken into consideration the charging of the BBU from the +12
3.3.3
Thermal and Atmospheric Characteristics
The atmospheric characteristics for the RAID Controller SRCS16 are:
•
•
•
The following parameters define the storage and transit environment for the RAID Controller
SRCS16:
•
•
3.3.4
Safety Characteristics
The RAID Controller SRCS16 meets or exceeds the requirements of UL flammability rating
94 V0. Each board is marked with the supplier's name or trademark, type, and UL
flammability rating. Because these boards are installed in a PCI bus slot, all voltages are
below the SELV 42.4 V limit.
Technical Specifications
RAID Controller SRCS16 Maximum Power Requirements
PCI/PCI-X +5.0 V
1
0.85 A
1
1.63 A
V and the on-board regulator efficiencies.
Temperature range: 0 °C to 45 °C (dry bulb)
Relative humidity range: 20% to 80% noncondensing
Maximum dew point temperature: 32 °C
Temperature range: 40 °C to 105 °C (dry bulb)
Relative humidity range: 20% to 80% noncondensing
PCI/PCI-X +3.3 V
Power
1.29 A
11 W
0 A
Over the Operating
Range
0 °C to 45 °C
24