VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
INSTALLATION
Continued
MANTEL CLEARANCES FOR
BUILT-IN INSTALLATION
If placing mantel above built-in fireplace,
you must meet minimum clearance between
mantel shelf and top of fireplace opening.
NOTICE: Surface temperatures of
adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the firebox
may become hot to the touch. If
installed properly, these tempera-
tures meet the requirement of the
national product standard. Fol-
low all minimum clearances
shown in this manual.
NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• raise the mantel to an accept-
able height
• remove the mantel
10"
Note:
8"
All vertical
measurements
6"
are from top of
1
2
/
"
fireplace
2
opening to
bottom of
mantel shelf. All
measurements
are in inches.
Side of
Firebox
Figure 12 - Minimum Mantel Clearances
for Built-In Installation
CGCFTP
OPTIONAL MANTEL
INSTALLATION
Note: Refer to instructions provided with
the mantel for assembly instructions. Refer
to instructions below for system installa-
tion. Refer to instructions on page 4 for
firebox assembly. Blower accessory should
be installed if it is being used (see Installing
Blower Accessory GA3450T, pages 11
through 13).
1. Unscrew four brass screws that attach
top louver to fireplace. Remove louver
from fireplace and set aside.
2. Place fireplace on wood base.
3. Place mantel around fireplace/base
assembly.
4. Assemble brass trim kit. See Assem-
bling Brass Trim, page 11.
5. Firmly snap brass trim kit on shoulder
screws. Shoulder screws are located on
fireplace cabinet (see Figure 13).
6. Align brass trim kit for flush fit around
opening.
7. Use two 3" wood screws provided and
attach fireplace base to wooden base
(see Figure 13).
Shoulder Screws
Mantel Shelf
Hole for 3"
Wood Screw
for Attaching
Fireplace to
Mantel
Figure 13 - Attaching Brass Trim to Fireplace
1
3
/
" Screw
4
Figure 14 - Attaching Wood Base to Floor
8.
9.
10. Attach wood base to floor with two 1
11. Install gas line. See Connecting To Gas
12. Check for leaks. See Checking Gas
13. Place mantel around fireplace. Be care-
14. Place brass trim kit on the shoulder
15. Adjust assembly to remove any gaps.
16. Reinstall top louvers.
Assembled
Brass Trim
10
Remove brass trim kit and mantel. Be
careful not to damage wall or mantel.
Place wood base next to wall at instal-
lation location.
black screws provided (see Figure 14).
If the floor is concrete use anchor
method (see Attaching Wood Base to
Solid Floor, page 14).
Supply, page 14.
Connections, page 16.
ful not to damage wall or mantel.
screws located on the side and top of
the fireplace. Firmly snap the brass trim
over the shoulder screws on fireplace
(see Figure 13).
Attach remaining two 3" wood screws
from hardware pack through openings
inside of fireplace sides into the mantel.
The openings are located at top behind
the area for the louvers (see Figure 13).
Hole for 3"
Wood Screw
for Attaching
Fireplace to
Wooden Base
Wood Base
3
/
"
4
107036