INSTALLATION INSTRUCTIONS

PREPARING THE INSTALLATION LOCATION

IMPORTANT INSTALLATION INFORMATION
• All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60
hertz, AC-only electrical supply with ground.
• Minimum distance between cooktop and overhead cabinetry is 30 (76.2 cm).
(76.2 cm)
All dimensions are stated in inches and millimeters (mm).
Allow 2 (5 cm) space below the armored cable opening to clear the electric cable and
allow space for installation of the junction box on the wall at the back of the cooktop.
LGE Internal Use Only
30" Min.
** Do not obstruct these areas!
- 11 -
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
4" X 8" (10.2 cm x 20.3 cm)
opening to route armored
cable if panel is present.