INSTALLATION INSTRUCTIONS
PREPARING THE INSTALLATION LOCATION
IMPORTANT INSTALLATION INFORMATION
• All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60
hertz, AC-only electrical supply with ground.
• Minimum distance between cooktop and overhead cabinetry is 30" (762 mm).
• Make sure the cabinets and wall coverings around the cooktop can withstand the
temperatures (up to 93˚C [200˚F]) generated by the cooktop.
30
(762 mm)
LCE3610SB Radiant Cooktop
All dimensions are stated in inches and millimeters (mm).
Allow 2" (50 mm) space below the armored cable opening to clear the electric cable and
allow space for installation of the junction box on the wall at the back of the cooktop.
LGE Internal Use Only
"
min.
** Do not obstruct these areas!
36 inch Radiant Cooktop
- 13 -
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
"
"
4
X 8
(102 mm x 203 mm)
opening to route armored
cable if panel is present.