8. Pull ember material apart into pieces no larger
than a dime. Place these pieces loosely and
sparingly directly onto exposed section of
front burner and along space between burner
and grate prongs (see Figure 46). This will
create glowing ember appearance as flame
touches ember material. Do not block air slots
by using too much ember material in one area.
It is not necessary to use all of ember material
provided.
9. Close glass door, lock door latches, replace
screen and close louvers (see Removing/Replac-
ing Glass Door, steps 5 through 7, page 23).
WARNING: The glass door
must be securely in place before
running this fireplace. Do not run
this fireplace if glass is missing
or broken.
Ember Material
Figure 46 - Placing Ember Material on

WALL SWITCH INSTALLATION

Installation of a wall switch allows you to activate
gas control valve and turn fireplace on and off. The
wall switch is to be connected to incoming 120 volt
regular household wiring that supplies electricity
to fireplace. Refer to wiring diagram, page 27.
6
Burner
www.desatech.com
OpTIONAL REMOTE CONTROL
INSTALLATION (MODEL WRC)
Note: If using optional wireless hand-held remote
control, wall switch must be in ON position to be
operational. Remote control then becomes switch-
ing mechanism for fireplace operation.
1. Open lower louver panel of firebox.
2. WRC model receiver does not require a bat-
tery. Receiver can be installed by first plugging
short extension cord into fireplace receptacle.
Plug receiver unit into extension cord. Finally
plug ignition module plug into receiver unit
(see Figure 47).
3. Activate remote handset battery by removing
insulating tab on back of handset (see Figure
48). Battery is included pre-installed.
4. Once battery is activated unit is ready to use.
5. Close lower louver panel.
Fireplace
Receptacle
Extension
Cord
Figure 47 - Installing the WRC Remote
Receiver
Battery Cover
1 Volt Battery
Figure 48 - Installing Battery into Back of
Handset
Remote
Control
Receiver
Ignition Module
Plug
Back of
Handset
Pull to Remove
Insulation Tab
111987-01D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vt32ep seriesT32en seriesT32ep series

Table of Contents