FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance is equipped with an ignition
device which automatically lights the pilot.
Do not try to light by hand.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the gas
supplier's instructions.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand,
don't try to repair it, call a qualified service
technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be pres-
ent. Open damper or window to
vent smell. This will only last a
few hours.
1. STOP! Read the safety information,
above.
2. Turn off all electric power to the appliance.
3. Turn wall switch to the OFF position.
4. Open lower louver panel.
8

OPERATING FIREPLACE

www.desatech.com
5. Turn equipment shutoff valve clockwise
to the OFF position (see Figure 49).
Do not force.
6. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the
safety information in column 1. If you don't
smell gas, go to the next step.
7. Turn equipment shutoff valve counter-
clockwise
not force.
8. Close lower louver panel.
9. Turn on all electric power to the appli-
ance.
10. Turn the wall switch to the ON position.
11. Visually locate the pilot. The ignitor should
begin to spark and the main burner should
ignite once flame appears at pilot.
• If lighting the appliance for the first time
each season, it may take several attempts
before the supply gas can reach the pilot
and main burners.
• If the appliance will not stay lit after
several attempts, follow the instructions
To Turn Off Gas To Appliance, page 29,
and call your service technician or gas
supplier.
Equipment
Shutoff Valve
Figure 48 - Turning Equipment Shutoff
Valve to the OFF Position
Pilot
Burner
Figure 49 - Pilot
to the ON position. Do
Adjustment
Screw
Sensing
Rod
Ignitor
111987-01D