Installation; Wall Switch Installation - Desa P325E(B) Owner's Operation And Installation Manual

Desa b-vent decorative gas fireplace owner's operation and installation manual p324e, vp324e, p325e(b), vp325e(b)
Table of Contents

Advertisement

INSTALLATION

10

Wall Switch Installation

Optional Remote Control Installation (Model WRC)
Gas Line Hook-Up
INSTALLATION
WALL SWITCH INSTALLATION
The installation of a wall switch allows you to activate the gas
control valve and turn the fireplace on and off. The wall switch is to
be connected to the incoming 120 volt regular household wiring that
supplies the electricity to the fireplace. Refer to wiring diagram in
this manual on page 18.
OPTIONAL REMOTE CONTROL
INSTALLATION (Model WRC)
Note: If using optional wireless hand-held remote control, the wall
switch must be in the ON position to be operational. The remote control
then becomes the switching mechanism for fireplace operation.
1. Remove the front refractory access panel by lifting up and an-
gling out of the firebox opening (see Figure 12).
2. The WRC model receiver does not require a battery. The re-
ceiver can be installed by first plugging the short extension
cord into the fireplace receptacle. Then plug the receiver unit
into the extension cord. Finally plug the ignition module plug
into the receiver unit (see Figure 13).
3. Activate the remote handset battery by removing the insulat-
ing tab on the back of the handset (see Figure 14). The battery
is included pre-installed.
4. Once the battery is activated the unit is ready to use.
5. Replace front refractory access panel.
Figure 12 - Removing Front Refractory Access Panel
(P325E/VP325E Model Shown)
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Fireplace
Receptacle
Extension Cord
Figure 13 - Installing the WRC Remote Receiver
Battery Cover
12 Volt Battery
Back of
Handset
Figure 14 - Installing Battery into Back of Handset
GAS LINE HOOK-UP
WARNING: Gas line hookup should be done by
your gas supplier or a qualified service person.
WARNING: Before you proceed, make sure your
gas supply is OFF.
The appliance and it's individual shutoff valve must be discon-
nected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system
by closing its individual equipment shutoff valve during any pres-
sure testing of the gas supply piping system at test pressures equal
to or less than 1/2 psig (3.5 kPa).
An equipment shutoff valve has been included in the appliance's
gas supply system. You may consider installing an extra gas shutoff
valve outside the appliance's enclosure (check with local codes)
where it can be accessed more conveniently with a key through a
wall as shown in Figure 15.
Key
Typical Exterior Wall Gas
Shutoff Installation
Figure 15 - Equipment Shutoff Valve Installation
Remote Control
Receiver
Ignition
Module Plug
Pull to Remove
Insulation Tab
Shutoff
Valve
Extension
108794-01D