Desa (V)T32EN SERIES Owner's Operation And Installation Manual page 22

Direct-vent fireplace ng/lp “tudor” models
Table of Contents

Advertisement

FIREPLACE
INSTALLATION
Continued
pRESSURE TESTING GAS SUppLY
pIpING SYSTEM
Test pressures In Excess Of 1/2 pSIG
(3.5 kPa)
1. Disconnect fireplace and its individual equip-
ment shutoff valve from gas supply piping
system. Pressures in excess of 1/2 psig (3.5 kPa)
will damage fireplace gas regulator.
2. Cap off open end of gas pipe where equipment
shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas fireplace or opening main gas
valve located on or near gas meter for natural
gas fireplace, or using compressed air.
4. Check all joints of gas supply piping system.
Apply noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak. Correct
all leaks at once.
5. Reconnect fireplace and equipment shutoff
valve to gas supply. Check reconnected fittings
for leaks.
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 34).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas fireplace or opening main gas
valve located on or near gas meter for natural
gas fireplace, or using compressed air.
3. Check all joints from propane/LP supply tank
or gas meter to equipment shutoff valve (see
Figure 35 for propane/LP or Figure 36 for
natural gas). Apply noncorrosive leak detec-
tion fluid to all joints. Bubbles forming show
a leak. Correct all leaks at once.
Equipment
Shutoff Valve
Figure 34 - Equipment Shutoff Valve

Propane/LP
Supply Tank
pRESSURE TESTING FIREpLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 34).
2. Open main gas valve located on or near gas
3. Make sure control knob of fireplace is in the
4. Check all joints from equipment shutoff valve
5. Light fireplace (see Operating Fireplace, page
Open
6. Turn off fireplace (see To Turn Off Gas to
Closed
www.desatech.com
Equipment
Shutoff Valve
Figure 35 - Checking Gas Joints for
Propane/LP Gas Fireplace
Equipment Shutoff Valve
Gas
Meter
Figure 36 - Checking Gas Joints for
Natural Gas Fireplace
meter for natural gas or open supply tank
valve for propane/LP gas.
OFF position.
to thermostat gas valve (see Figure 35 or 36).
Apply noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak. Correct
all leaks at once.
28). Check all other internal joints for leaks.
Appliance, page 29).
Gas Valve
Gas Valve
111987-01D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vt32ep seriesT32en seriesT32ep series

Table of Contents