Wall Switch Installation - Desa (V)TC36PE SERIES, (V)TC36NE SERIES Owner's Operation And Installation Manual

Direct-vent fireplace
Table of Contents

Advertisement

FIREPLACE
INSTALLATION
Continued
6. Install rear brick panel first. Rest bottom edge
of panel on back edge of burner assembly (see
Figure 39).
7. Install left side brick panel by sliding it be-
tween the burner assembly and the side of the
firebox (see Figure 39).
8. Install the right brick panel using the same
method described in step 6 for left brick
panel.
9. Replace deflector shield using screws removed
in step 4.
10. Using scews removed in step 4, replace ple-
num and attach to burner.
11. Using screws removed in step 3, replace
log/grate assembly. Be careful when replac-
ing log/grate assembly not to chip logs on
burner.
12. Install lava rock and glowing embers. See
Installing Lava Rock and Glowing Embers,
page 25.
13. Close glass door and lock latches on top and
bottom of door and replace screen. See Re-
moving Glass Door, steps 5 and 6, page 25.
14. Close top and bottom louvers.
Left Side Brick
Panel
Rear Brick
Panel
Figure 39 - Installing Rear Brick Panel
26

WALL SWITCH INSTALLATION

The installation of a wall switch allows you to ac-
tivate the gas control valve and turn the fireplace
on and off. The wall switch is to be connected to
the incoming 120 volt regular household wiring
that supplies the electricity to the fireplace.
OPTIONAL REMOTE CONTROL
INSTALLATION (MODEL WRC)
Note: If using optional wireless hand-held remote
control, the wall switch must be in the ON position
to be operational. The remote control then becomes
the switching mechanism for fireplace operation.
1. Open lower louver panel.
2. The WRC model receiver does not require a
battery. The receiver can be installed by first
plugging the short extension cord into the
fireplace receptacle. Then plug the receiver
unit into the extension cord. Finally plug the
ignition module plug into the receiver unit (see
Figure 40).
3. Activate the remote handset battery by
removing the insulating tab on the back of
the handset (see Figure 41). The battery is
included pre-installed.
4. Once the battery is activated the unit is ready
to use.
5. Close lower louver panel.
Fireplace
Receptacle
Extension Cord
Figure 40 - Installing the WRC Remote
Figure 41 - Installing Battery into Back of
www.desatech.com
Receiver
Battery Cover
12 Volt Battery
Back of
Handset
Handset
Remote
Control
Receiver
Ignition
Module Plug
Pull to Remove
Insulation Tab