Dell DX6000 Hardware Owner's Manual page 50

Hardware owner's manual
Hide thumbs Also See for DX6000:
Table of Contents

Advertisement

Table 1-2. System Messages
Message
The following
DIMMs should
in
match
geometry:
x,x,...
The following
DIMMs should
in rank
match
count:
x,x,...
The following
DIMMs should
match in size:
x,x,...
The following
DIMMs should
in size
match
and geometry:
x,x,...
The following
DIMMs should
in size
match
and rank count:
x,x,...
Thermal sensor
not detected on
x.
Time-of-day
clock stopped.
Time-of-day not
set - please run
SETUP program.
50
About Your System
(continued)
Causes
Invalid memory
configuration. The specified
memory modules do not
match in size, number of
ranks, or number of data
lanes.
A memory module without a
thermal sensor is installed in
the specified memory slot
Faulty battery or faulty chip. See "Troubleshooting the
Incorrect Time or Date
settings; faulty system
battery.
Corrective Actions
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module Installation
Guidelines" on page 131.
Replace the memory module.
See "System Memory" on
page 130.
System Battery" on page 160.
Check the Time and Date
settings. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 57. If the problem
persists, replace the system
battery. See "System Battery"
on page 143.

Advertisement

Table of Contents
loading

Table of Contents