Dell DX6000 Hardware Owner's Manual page 29

Hardware owner's manual
Hide thumbs Also See for DX6000:
Table of Contents

Advertisement

Table 1-1. LCD Status Messages
Code
Text
E1629 Power
required >
PSU wattage.
Check PSU and
config.
E1710 I/O channel
check error.
Review &
clear SEL.
E1711 PCI parity
error on Bus
## Device ##
Function ##
PCI parity
error on Slot
#. Review &
clear SEL.
(continued)
Cause
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
The system BIOS has
reported an I/O channel
check.
The system BIOS has
reported a PCI parity error
on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.
The system BIOS has
reported a PCI parity error
on a component that
resides in the specified slot.
Corrective Actions
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 189.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 170.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 170.
About Your System
29

Advertisement

Table of Contents
loading

Table of Contents