Dell DX6000 Hardware Owner's Manual page 40

Hardware owner's manual
Hide thumbs Also See for DX6000:
Table of Contents

Advertisement

Table 1-2. System Messages
Message
Alert! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
Alert! Redundant
memory disabled!
Memory
configuration
does not support
redundant
memory.
Alert! System
fatal error
during previous
boot.
40
About Your System
(continued)
Causes
The system configuration of
processor(s), memory
modules, and expansion
cards may not be supported
by the power supplies.
Memory Mirroring was
enabled in the system setup
program, but the current
configuration does not
support redundant memory.
A memory module may be
faulty.
An error caused the system
to reboot.
Corrective Actions
If any system components
were just upgraded, return
the system to the previous
configuration. If the system
boots without this warning,
then the replaced
component(s) are not
supported with this power
supply. If Energy Smart
power supplies are installed,
replace them with the High
Output power supplies to use
the components. See "Power
Supplies" on page 90.
Check the memory modules
for failure. See
"Troubleshooting System
Memory" on page 163. Reset
the memory setting, if
appropriate. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 57.
Check other system
messages for additional
information for possible
causes.

Advertisement