Electrolux E46GC67ESS - 46" Sealed Burner Gas Cooktop Installation Instructions Manual page 27

Installation instructions
Hide thumbs Also See for E46GC67ESS - 46" Sealed Burner Gas Cooktop:
Table of Contents

Advertisement

Instructions for converting cooktop to operate on Liquefied Petroleum Gas
IF RETURN TO NATURAL GAS SERVICE IS REQUIRED, REPEAT ALL STEPS EXCEPT USE THE
FOLLOWING TABLES TO DETERMINE THE LOCATIONS FOR THE NATURAL GAS ORIFICES AND
SHUTTER GAPS. ALL ORIFICE SHOULD HAVE BEEN SAVED FOR FUTURE USE. AGAIN SAVE THE
LPG/PROPANE ORIFICES FOR THE CASE WHERE CONVERSION IS AGAIN REQUIRED.
MODEL NUMBER: E30GC64ESS
ORIFICE SIZES ARE IN MILLIMETERS X 100 AND SHUTTER GAP IS IN INCHES.
Burner Position
LEFT FRONT
RIGHT FRONT
LEFT REAR
RIGHT REAR
MODEL NUMBER: E36GC65ESS
ORIFICE SIZES ARE IN MILLIMETERS X 100 AND SHUTTER GAP IS IN INCHES.
Burner Position
LEFT FRONT
RIGHT FRONT
CENTER
LEFT REAR
RIGHT REAR
MODEL NUMBER: E46GC66ESS
ORIFICE SIZES ARE IN MILLIMETERS X 100 AND SHUTTER GAP IS IN INCHES.
Burner Position
LEFT FRONT
RIGHT FRONT
CENTER FRONT
LEFT REAR
RIGHT REAR
CENTER REAR
MODEL NUMBER: E46GC67ESS
ORIFICE SIZES ARE IN MILLIMETERS X 100 AND SHUTTER GAP IS IN INCHES.
Burner Position
LEFT FRONT
RIGHT FRONT
GRILL
LEFT REAR
RIGHT REAR
ORIFICE AND SHUTTER DATA FOR NATURAL GAS.
Main Orifice
176
132
132
162
ORIFICE AND SHUTTER DATA FOR NATURAL GAS.
Main Orifice
171
128
161
128
161
ORIFICE AND SHUTTER DATA FOR NATURAL GAS.
Main Orifice
176
176
130
138
125
169
ORIFICE AND SHUTTER DATA FOR NATURAL GAS.
Main Orifice
132
175
150
165
132
Bypass Orifice
59
54
54
57
Bypass Orifice
60
50
54
50
54
Bypass Orifice
63
63
57
57
57
58
Bypass Orifice
53
60
136
59
53
9
Shutter Gap
.25
.25
.29
.34
Shutter Gap
.36
.27
.33
.36
.39
Shutter Gap
.37
.20
.27
.15
.15
.22
Shutter Gap
.14
.25
.18
.23
.24

Advertisement

Table of Contents
loading

This manual is also suitable for:

E30gc64essE36gc65essE46gc66ess5995426250

Table of Contents