Shutting Off Fireplace
1. Turn control knob clockwise
2. If Using Optional Hand-Held Remote: Set selector switch
in the OFF position to prevent draining battery.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one
of the following:
1.
Turn control knob clockwise
2. If Using Optional Hand-Held Remote: Use remote con-
trol manual OFF button.
WARNING: Make sure remote sensor selector
switch is in the OFF position when you are away from
home for long periods of time.
MANUAL LIGHTING
PROCEDURE
1.
Follow steps 1 through 5 under Lighting Instructions, page 21.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
steps 8 and 9 under Lighting Instructions, page 21.
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be purchased sepa-
rately (see Accessories, pages 36 and 37). Follow instructions
included with the remote control.
NOTICE: You must light the pilot before using the
hand-held remote control unit. See Lighting Instruc-
tions on page 21.
1. After lighting, let pilot flame burn for about one minute.
Turn control knob to ON position. Adjust flame adjustment
knob anywhere between HI and LO. Slide the selector switch
to the REMOTE position (see Figure 42). Note: The burner
may light if hand-held remote was on when selector switch
was last turned off. You can now turn the burner on and off
with the hand-held remote control unit.
IMPORTANT: Do not leave the selector switch in the RE-
MOTE or ON position when the pilot is not lit. This will
drain the battery.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
to the OFF position.
Figure 42- Setting the Selector Switch, Control Knob and Flame
Adjustment Knob for Remote Operation
ON/OFF SERIES (MODEL [C]GHRCB)
Hold the control button on the hand-held remote until burner
to the PILOT position.
turns on. Hold the control button again until burner turns off
(see Figure 43).
TO LOCK
light stops flashing. Hand-held remote control is now locked. If
the fire is on it will be turned off automatically. In the locked
state, the light will not light up when any button is pressed.
TO UNLOCK
control until the light stops flashing. The hand-held remote is
now unlocked.
Figure 43 - On/Off Hand-Held Remote Control Unit (GHRCB)
THERMOSTAT SERIES (MODEL [C]GHRCTB)
The hand-held remote can be operated using either the manual mode
(MANU) or thermostatic mode (AUTO) (see Figure 44, page 23). To
select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F
mode button with the end of a paper clip or similar blunt object.
Manual Mode
1. Press the POWER and LOCK buttons together to turn on
2. Press the MANU button to turn on the fireplace.
3. Press the POWER and LOCK buttons together to turn off
Auto (Thermostatic) Mode
1. Press the POWER and LOCK buttons together to turn on
2. Press AUTO button to select this mode.
3. Set the desired room temperature by pressing the TEMP
4. Press the POWER and LOCK buttons together to turn off
Selector Switch in Remote
Position (Optional Remote
Control)
REMOTE
OFF
ON
press both buttons on hand-held remote control until
press both buttons together on hand-held remote
the hand-held remote control.
the fireplace.
the hand-held remote control.
+ or - buttons.
the fireplace
Flame
Adjustment
Knob
Control Knob
IN
OUT
LO
Control Button
Turns Burners
On and Off