INSTALLATION
Continued
INSTALLING LOG SET AND SCREEN
1. Remove log packaging material and discard packaging. Gen-
tly place log over burner (see Figure 34). Do not allow log to
contact flame. If flame contacts log, soot will be created.
2. Reattach screen by placing the notches in the screen frame
over the shoulder screws and pushing down.
Shoulder Screw
Log
Screen
Figure 34 - Installing Log and Screen

OPERATING FIREPLACE

THERMOSTAT-CONTROLLED MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
111244-01A
OPERATING FIREPLACE (THERMOSTAT-CONTROLLED MODELS)
C. Use only your hand to push in or turn the gas control knob.
D. Do not use this appliance if any part has been under water.
the screen in place. Make sure fireplace screen is
installed before running fireplace.
NOTICE: During initial operation of new fireplace,
burning logs will give off a paper-burning smell. Open
window to vent smell. Operate fireplace on HI position
to burn off odor. This will only last a few hours.
1. STOP! Read the safety information above.
2. Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise
4. Wait five (5) minutes to clear out any gas. Then smell for
5. Turn control knob counterclockwise
Figure 35 - Control Knob In The OFF Position
Installing Log Set and Screen
For Your Safety Read Before Lighting
Lighting Instructions
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire de-
partment.
Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
WARNING: You must operate this fireplace with
gas, including near the floor. If you smell gas, STOP! Fol-
low "B" in the safety information in column 1. If you don't
smell gas, go to the next step.
LOT position. Press in control knob for five (5) seconds
(see Figure 35).
Note: You may be running this fireplace for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
• If control knob does not pop out when released, contact
a qualified service person or gas supplier for repairs.
Ignitor
Button
INSTALLATION
19
19
to the OFF position.
Clockwise
to the PI-
C-clockwise
Control Knob