Control Valve
Programming and Cover Drawing Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EQ and is the answer not in the manual?

Questions and answers

Summary of Contents for Water Specialist EQ

  • Page 1 Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual...
  • Page 2 Page 2 CK and EQ Manual...
  • Page 3: Table Of Contents

    Page 3 CK and EQ Manual Table of Contents CK Front Cover and Drive Assembly ..........................4 OEM General Programming Instructions ........................5 OEM Cycle Sequence ..............................7 OEM Softener System Setup ............................13 Setting Options Table ..............................16 OEM Filter System Setup ............................17 Installer Display Settings .............................
  • Page 4 Page 4 CK and EQ Manual CK and EQ Front Cover and Drive Assembly Drawing No. Order No. Description Quantity V3692-01GD WS1LP FRONT COVER ASSEMBLY GD V3107-01 WS1 MOTOR ASY V3106-01 WS1 DRIVE BRACKET & SPRING CLIP V3757CK-02BOARD WS1 THRU 2 CK PC BRD REPL...
  • Page 5: Oem General Programming Instructions

    Page 5 CK and EQ Manual OEM General Programming Instructions The control valve offers multiple procedures that allow the valve to be modified to suit the needs of the installation. These procedures are: • OEM Cycle Sequence • User Display Settings •...
  • Page 6 Page 6 CK and EQ Manual Once the OEM Cycle Sequence has been set, the other procedures can be accessed in any order. Details on each of the procedures are provided on the following pages. To “lock out” access to diagnostic and valve history displays and modifications to settings except hardness, day override, time of regeneration and time of day by anyone but the manufacturer, press ▼, NEXT, ▲, and CLOCK in sequence after settings are...
  • Page 7 Page 7 CK and EQ Manual OEM Cycle Sequence OEM Cycle Sequence instructions allows the OEM to set the order of Cycle Options the cycle. The OEM Softener System Setup or the OEM Filter System BACKWASH DN BRINE FILL Setup allow the OEM to set how long cycles will last. The OEM may choose up to 9 cycles in any order.
  • Page 8 Page 8 CK and EQ Manual ▲ or ▼ : Step 4CS – Allows selection of one of the following using STEP 4CS • the Control Valve to act as an alternator; or • the Control Valve to have a no hard water bypass: or •...
  • Page 9 Page 9 CK and EQ Manual Retracted Extended Valve “B” in Service Position = MAV Valve “A” in Service Position = piston rod Extended MAV piston rod Retracted Note: Clack Twin Alternator Operations • Twin alternating systems can be programmed with a day override setting combined with the normal volume-based regeneration programming.
  • Page 10 Page 10 CK and EQ Manual Step 5CS – Set Auxiliary Drive Output (MAV only) to operate in one of three modes: STEP 5CS • Set TIME: Allows Auxiliary MAV to switch positions at a set time in relation to the start of regeneration for a preset duration, independently of the actual regeneration status.
  • Page 11 Page 11 CK and EQ Manual Step 6CS – This allows the use of an outside signal to control the initiation of a regeneration. STEP 6CS Selection only matters if a connection is made to the two pin connector labeled DP SWITCH located on the printed circuit board.
  • Page 12 Page 12 CK and EQ Manual STEP 8CS Step 8CS – Press ▲ or ▼ until BACKWASH appears. Press NEXT to go to Step 9CS. Press REGEN to return to previous step. Step 9CS - Press ▲ or ▼ until Regenerant Draw DN appears. Prior to selecting the upflow regeneration...
  • Page 13 Page 13 CK and EQ Manual OEM Softener System Setup In OEM Softener System Setup the OEM chooses the time for the cycles selected in OEM Cycle Sequence and specifies other operating parameters for the system. The upper and lower limits of the allowable values for the cycles are as follows:...
  • Page 14 Page 14 CK and EQ Manual Step 6S – Select the kg for the fourth cycle (which in this example is FILL) using ▲ or ▼. When 2.0 STEP 6S is selected in Step 2CS, FILL is in minutes. If 1.5 is selected in Step 2CS, setting the last step of the OEM Cycle Sequence determines if the value here is kg or minutes.
  • Page 15 Page 15 CK and EQ Manual STEP 11S ▲ or ▼ Step 11S: Set Relay 1 SETPOINT Time or Volume using . The choices are: • Relay Actuation Time: After the start of a regeneration the amount of time that should pass prior to activating the relay.
  • Page 16: Setting Options Table

    Page 16 CK and EQ Manual Setting Options Table Filters should only use shaded options. Volume Regeneration Result Capacity Time Option Override Reserve capacity automatically estimated. DELAYED AUTO Regeneration occurs when volume capacity falls below the reserve REGEN capacity at the next Regen Set Time Reserve capacity automatically estimated.
  • Page 17: Oem Filter System Setup

    Page 17 CK and EQ Manual OEM Filter System Setup In OEM Filter System Setup the OEM chooses the time for the cycles selected in OEM Cycle Sequence and specifies other operating parameters for the system. The upper and lower limits of the allowable values for the cycles are as follows:...
  • Page 18 Page 18 CK and EQ Manual Step 6F – Select the liters for the fourth cycle (which in this example is FILL) using ▼ or ▲. When STEP 6F 2.0 is selected in Step 2CS, FILL is in minutes. Press NEXT to go to Step 7F. Press REGEN to return to previous step.
  • Page 19 Page 19 CK and EQ Manual Step 10F – Set Relay 1 SETPOINT Time or Volume using ▲ or ▼. The choices are: STEP 10F • Relay Actuation Time: After the start of a regeneration the amount of time that should pass prior to activating the relay.
  • Page 20: Installer Display Settings

    Page 20 CK and EQ Manual Installer Display Settings STEP 1I STEP 1I - Press NEXT and ▲ simultaneously for 3 seconds. STEP 2I STEP 2I – Set Display Language. Select between English, German, French or Spanish. Press NEXT to go to Step 3I. Press REGEN to exit Installer Display Settings.
  • Page 21: User Display Settings

    Page 21 CK and EQ Manual User Display Settings When the system is operating, several displays may be shown. Pressing NEXT will alternate between the displays. One of the displays is the current time of day. CAPACITY REMAINING is the cubic meters that will be treated before the system goes through a regeneration cycle.
  • Page 22 Page 22 CK and EQ Manual Regeneration Mode Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when a household is asleep. If there is a demand for water when the system is regenerating, untreated water will be used.
  • Page 23 Page 23 CK and EQ Manual Power Loss If the power goes out the system will keep time until the battery is depleted. If an extended power outage occurs, the time of day will flash on and off which indicates the time of day should be reset and the non rechargeable battery replaced. The system will remember the rest.
  • Page 24: Diagnostics

    Page 24 CK and EQ Manual Diagnostics STEP 1D – Press ▲ and ▼ simultaneously for three seconds. If screen in step 2D does not appear STEP 1D in 5 seconds the lock on the valve is activated. To unlock press ▼, NEXT, ▲, and CLOCK in sequence, then press ▲...
  • Page 25 Page 25 CK and EQ Manual STEP 7D – Flow rate, maximum last seven days: Use ▲ or ▼ to display the maximum flow rate in STEP 7D liters per minute that occurred in each of the last seven days. This display will equal zero if a water meter is not installed.
  • Page 26: Valve History

    Page 26 CK and EQ Manual Valve History STEP 1VH STEP 1VH – Press ▲ or ▼ simultaneously for three seconds and release. Then press ▲ and ▼ simultaneously and release. If screen in step 2VH does not appear in 5 seconds the lock on the valve is activated.
  • Page 27 Revision History: 12/10/2013 COVER added EQ to cover and page body headers PAGE 4: V3757CK-02BOARD WS1 THRU 2 CK PC BRD REPL V3757EQ-02BOARD WS1 THRU 2 EQ PC BRD REPL 6/12/2014 PAGE 4: New board drawing Relay Driver Output Type – Dual Solid-State 12VDC “wet” contacts - N.O.
  • Page 28 Page 28 CK and EQ Manual Form No. V3435CK • 6/16/2014 U.S. Patents: 6,402,944 • 6,444,127 • 6,776,901 Translation supported by Pollet Water Group...