Page 4 WS1HR & WS1.25HR Manual Introduction This manual is about a control valve to be used on water softeners or water fi lters. The manual is designed to aid water treatment equipment manufacturers in the selection of the various control valve options. Information in this manual is different than what is needed for installation and servicing of a particular water treatment system.
The WS1.25HR control valve is only available in downfl ow regeneration. When the WS1HR or WS1.25HR control valve is set up as a fi lter, the control valve can be set to perform downfl ow regeneration or simply backwash.
Page 7
10. Bypass Valve (optional) Note: The WS1HR & WS1.25HR share many of the same components. Refer to Figure 6 for control valve identifi cation. See Installer Display Settings, OEM Softener System Setup and OEM Filter System Setup for explanations of Day Override and Gallon Capacity.
(U.S. Patent 6444127). One of three main pistons is always used: 1. A 1.25" diameter downfl ow piston is used when the WS1HR control valve is used as a downfl ow softener, regenerating fi lter or non-regenerating fi lter.
• no regenerant WS1HR & WS1.25HR (both the DN and UP holes have injector plugs installed) and plug installed for the refi ll elbow NOTE: It is not recommended to fi eld convert valves from upfl ow to downfl ow and vice versa. Separate areas in the valve supply water to the injector for upfl...
Page 10 WS1HR & WS1.25HR Manual The refi ll fl ow control assembly is installed in an easy to access refi ll elbow located on top of the control valve. The refi ll fl ow control assembly is attached to the control valve with a locking clip. The locking clip allows the elbow to rotate 270 degrees so the outlet can be orientated towards the regenerant tank.
WS1HR & WS1.25HR Manual Page 11 Water Meter or Meter Plug The water meter is installed on the outlet side of the control valve. The water meter uses a turbine to measure gallons of treated water. The turbine rotates with the fl ow of water and reports its rate of rotation through Hall effect circuitry to the printed circuit (PC) board.
Page 12 WS1HR & WS1.25HR Manual The installation fi tting assemblies are sold in pairs and consist of two fi ttings, two nuts, two split rings and two o-rings. The installation fi tting assemblies and the bypass valve are sold separately from the control valve.
Page 14 WS1HR & WS1.25HR Manual OEM General Instructions The control valve offers multiple procedures that allow the valve to be modifi ed to suit the needs of the installation. These procedures are: • OEM Cycle Sequence • OEM Softener System Setup •...
WS1HR & WS1.25HR Manual Page 15 OEM Cycle Sequence Cycle Options OEM Cycle Sequence instructions allows the OEM to set the order of the cycle. The OEM Softener System Setup or the OEM BACKWASH DN BRINE FILL Filter System Setup allow the OEM to set how long cycles will...
Page 16
Page 16 WS1HR & WS1.25HR Manual Step 4CS – Press the ▼ or ▲ buttons until BACKWASH appears. Press NEXT to go to Step 5CS. STEP 4CS Press REGEN to return to previous step. Step 5CS - Press the ▼ or ▲ buttons until dn BRINE appears. Prior to selecting dn BRINE or UP STEP 5CS BRINE or not selecting a regenerant fl...
WS1HR & WS1.25HR Manual Page 17 OEM Softener System Setup In OEM Softener System Setup the OEM chooses the time for the cycles selected in OEM Cycle Sequence and specifi es other operating parameters for the system. The upper and lower limits of the allowable values for the cycles are as follows:...
Page 18
Page 18 WS1HR & WS1.25HR Manual Step 8S – Set Volume Capacity using the ▼ or ▲ button. If value is set to: STEP 8S • “AUTO” capacity will be automatically calculated and reserve capacity will be automatically estimated; • “oFF” regeneration will be based solely on the day override set (see Installer Display Settings Step 3I); or •...
Page 19
WS1HR & WS1.25HR Manual Page 19 Table 8 Softener Setting Options Gallons Regeneration Result Capacity Time Option Override Reserve capacity automatically estimated. AUTO NORMAL Regeneration occurs when gallons capacity falls below the reserve capacity at the next Regen Set Time.
Page 20 WS1HR & WS1.25HR Manual OEM Filter System Setup In OEM Filter System Setup the OEM chooses the time for the cycles selected in OEM Cycle Sequence and specifi es other operating parameters for the system. The upper and lower limits of the allowable values for the cycles are as follows:...
Page 21
WS1HR & WS1.25HR Manual Page 21 Step 7F – Set Volume Capacity using the ▼ or ▲ button. If value is set to: STEP 7F • “oFF” regeneration will be based solely on the day override set (see Installer Display/Settings Step 3I);...
Page 22
Page 22 WS1HR & WS1.25HR Manual Table 9 Filter Setting Options Gallons Regeneration Result Capacity Time Option Override Reserve capacity not automatically estimated. NORMAL Regeneration occurs at the next Regen Set Time when the specifi ed number number of days between regenerations is reached.
WS1HR & WS1.25HR Manual Page 23 Installer Display Settings STEP 1I STEP 1I - Press NEXT and ▲ simultaneously for 3 seconds. STEP 2I – Hardness: Set the amount of hardness in grains of hardness as calcium carbonate per STEP 2I gallon using the ▼...
Page 24 WS1HR & WS1.25HR Manual User Display Settings General Operation When the system is operating, one of fi ve displays may be ➟ shown. The displays normally rotate, however pressing NEXT will pause on the selected display for 5 minutes. Pressing NEXT will alternate between the displays.
Page 25
WS1HR & WS1.25HR Manual Page 25 Regeneration Mode Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when a household is asleep. If there is a demand for water when the system is regenerating, untreated water will be used.
Page 26 WS1HR & WS1.25HR Manual Diagnostics STEP 1D – Press ▲ and ▼ simultaneously for three seconds. If screen in step 2D does not appear in STEP 1D 5 seconds the lock on the valve is activated. To unlock press ▲, NEXT, ▼, and CLOCK in sequence, then press ▲...
WS1HR & WS1.25HR Manual Page 27 Valve History STEP 1VH – Press ▲ and ▼ simultaneously for three seconds and release. Then press ▲ and ▼ STEP 1VH simultaneously and release. If screen in step 2VH does not appear in 5 seconds the lock on the valve is activated.
Page 28 WS1HR & WS1.25HR Manual Installation Refi ll Flow Control Assembly or Refi ll Port Plug Control valves that are setup for backwash only come equipped with a refi ll port plug. The refi ll port plug has no regenerant line connection.
Page 29
WS1HR & WS1.25HR Manual Page 29 Installation Fitting Assemblies The installation fi ttings connect to the control valve or the bypass valve using nuts that only require hand tightening. Hand tighten nut connections between control valve and installation fi ttings, control valve and bypass valve, and bypass valve and installation fi...
Note: For upfl ow position, injector is located in the up hole and injector plug is in the other hole. WS1HR&HS upfl ow bodies are identifi ed by having the DN marking removed. For a fi lter that only backwashes, injector plugs are located in both holes.
WS1HR & WS1.25HR Manual Page 35 Refi ll Flow Control Assembly and Refi ll Port Plug Drawing No. Order No. Description Quantity V3195-01 WS1 Refi ll Port Plug Asy This part is required for backwash only systems H4615 Elbow Locking Clip JCP-P-6 Polytube insert 3/8”...
WS1HR & WS1.25HR Manual Page 45 WS1 Wrench (Order No. V3193-01) Although no tools are necessary to assemble or disassemble the valve, the WS1 wrench (shown in various positions on the valve) may be purchased to aid in assembly or disassembly.
Page 46 WS1HR & WS1.25HR Manual Service Instructions Drive Assembly Remove the valve cover to access the drive assembly. Disconnect the power source plug (black wire) from the PC board prior to disconnecting the motor or water meter plugs from the PC board.
Page 47
WS1HR & WS1.25HR Manual Page 47 Replace the motor if necessary. Do not lubricate the motor or the gears. To reinstall the motor, move the spring clip loop to the right and hold. Gently turn the motor while inserting so that the gear on the motor meshes with the gears under the drive gear cover.
Page 48
Inspect the black o-rings and clear lip seals for wear or damage. Replace the entire stack if necessary. Do not disassemble the WS1HR or WS1.25HR stack. The spacer stack assembly may be chemically cleaned (dilute sodium bisulfi te or vinegar) or wiped with a soft cloth.
Page 49
WS1HR & WS1.25HR Manual Page 49 Two holes are labeled DN and UP. Check for compliance. See Table. Compliance Table Regenerant Application Injector and/or Plug(s) Main Piston Stack Body Piston WS1HR Downfl ow Softener Injector in “DN” hole, Plug V3001 or...
Page 50
Page 50 WS1HR & WS1.25HR Manual With the nut removed, a slot at the top of the water meter is visible. Twist a fl at blade screwdriver in the slot between the control valve body and the meter. When the meter is part way out it is easy to remove the water meter from the housing. Once the water meter is removed from the control valve body, gently pull forward on the turbine to remove it from the shaft.
WS1HR & WS1.25HR Manual Page 51 Table 10 Troubleshooting Procedures Problem Possible Cause Solution a. AC Adapter unplugged a. Connect power b. No electric power at outlet b. Repair outlet or use working outlet 1. Timer does not display time of day c.
Page 52
Page 52 WS1HR & WS1.25HR Manual Problem Possible Cause Solution a. Motor not operating a. Replace motor b. No electric power at outlet b. Repair outlet or use working outlet c. Defective AC Adapter c. Replace AC Adapter 6. Control valve stalled in d.