Figure 34, Series-Parallel Configuration: 6-Volt Battery Wiring; Figure 35, Series-Parallel Configuration: 12-Volt Battery Wiring - Trace Engineering SW II - REV 4.01 Owner's Manual

Inverter/chargers with revision 4.01 software
Table of Contents

Advertisement

6V
6V
12V INVERTER
(Total Battery Capacity
= 200 Amp Hours)
6V
6V
6V
Each individual 6-volt battery capacity = 100 amp hours
NOTE: If "cross-tying" is not required, the "dash" (- - -) connections are not needed.

Figure 34, Series-Parallel Configuration: 6-Volt Battery Wiring

12V
12V
24V INVERTER
(Total Battery Capacity
= 100 Amp Hours)
Each individual 12-volt battery capacity = 50 amp hours
NOTE: If "cross-tying" is not required, the "dash" (- - -) connections are not needed.

Figure 35, Series-Parallel Configuration: 12-Volt Battery Wiring

Copyright  Trace Engineering Company, Inc.
5916 - 195th Street N. E.
Arlington, WA 98223
6V
6V
6V
6V
FUSED
DISCONNECT
6V
6V
6V
6V
6V
6V
6V
6V
12V
12V
12V
12V
FUSED
DISCONNECT
Telephone: 360/435-8826
Fax: 360/435-2229
www.traceengineering.com
TECHNICAL INFORMATION
6V
6V
6V
6V
24V INVERTER
(Total Battery Capacity
= 200 Amp Hours)
6V
FUSED
DISCONNECT
6V
6V
6V
12V
12V
12V
12V
48V INVERTER
(Total Battery Capacity
= 100 Amp Hours)
SW Series Inverter/Charger
Rev. B: Sept 1, 1999
6V
6V
FUSED
DISCONNECT
48V INVERTER
(Total Battery Capacity
= 200 Amp Hours)
12V
12V
FUSED
DISCONNECT
Page
Part No. 2031-5
109

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SW II - REV 4.01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents