Selecting the temperature unit
To change the temperature
display between ºC and ºF, press
button 1.
Confirm by pressing button 2.
Selecting the danger
temperature
Note:
This step can only be taken on
vehicles fitted with the optional
temperature sensor.
When the engine temperature
exceeds the set value, the
warning LED on the right lights
up.
Default value: 110 °C (230ºF)
Enter the value by pressing
button 1 in succession. To go on
to the next digit, press button 3.
Confirm by pressing button 2.
47
-
-
Selecting the warning
temperature
Note:
This step can only be taken on
vehicles fitted with the optional
temperature sensor.
When the engine temperature
exceeds the set value, the
warning LED on the left lights up.
Default value: 90 °C (190ºF)
Enter the value by pressing
button 1 in succession. To go on
to the next digit, press button 3.
Confirm by pressing button 2.
Selecting the rpm for a gear
change
When the set rpm is reached,
the left-hand warning LED
flashes to show that the gear
must be changed.
Default value: 6000 rpm
Enter the value by pressing
button 1 in succession. To go on
to the next digit, press button 3.
Confirm by pressing button 2.