Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
HT Manuals
Test Equipment
MACROEVTEST
User manual
HT MACROEVTEST User Manual
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
page
of
164
Go
/
164
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
1 Precautions and Safety Measures
Preliminary Instructions
During Use
After Use
Definition of Measurement (Overvoltage) Category
2 General Description
Foreword
Instrument Functions
3 Preparation for Use
Initial Checks
Instrument Power Supply
Storage
4 Nomenclature
Instrument Description
Description of Measuring Leads
Keyboard Description
Display Description
Initial Screen
5 General Menu
Instrument Settings
Language
Reference Country
Automatic Power off for Display and Key Sound
System
Operator Name Entry
System Date/Time Setting
Information
6 Operating Instructions
RPE: Continuity of Protective Conductors
Anomalous Situations
M: Measurement of Insulation Resistance
AUTO or L-PE Timer Mode
AUTO L/N-PE Mode
Anomalous Situations
RCD: Test on Differential Switches
AUTO Mode
AUTO+ Mode
X1, X2, X5 Modes
Mode X1 - Test on Rcds with Delay Time
Mode
Test on Earth Leakage Relay RCD
Anomalous Situations
LOOP: Line Impedance/Loop and Overall Earth Resistance
Test Types
Test Leads Calibration (ZEROLOOP)
STD Mode - Generic Test
Mode Ka - Verify of Breaking Capacity of Protection Device
Mode I 2 T - Verify of Protection against Short-Circuit
Mode - Verify of Protection Coordination
Mode - Verify of Protection Coordination - Norvay Country
Verify of Protection against Indirect Contacts (TN System)
Verify of Protection against Indirect Contacts (Notrip Test)
Verify of Protection against Indirect Contacts (no Trip Test - UK Country)
Verify of Protection against Indirect Contacts (IT Systems)
Verify of Protection against Indirect Contacts (TT Systems)
Impedance Measurement by Means of the Accessory IMP57
Anomalous Situations
SEQ: Phase Sequence and Phase Concordance Test
Anomalous Situations
LEAKAGE: Leakage Current Measurement
EARTH: Measurement of Earth Resistance
3-Wire or 2-Wire Earth Measurement and 4-Wire Ground Resistivity
3-Wire or 2-Wire Earth Measure - USA, Extra Europe and Germany Countries
Earth Measurement with Optional Clamp T2100
Anomalous Situations in 3-Wire and 2-Wire Earth Measurements
AUX: Measure of Ambient Parameters Via External Probes
V%: Voltage Drop of Main Lines
Anomalous Situations
AUTO TEST: Automatic Test Sequence (Notrip , RCD, M)
Autotest in TT Systems
Autotest in TN Systems
Anomalous Situations
PQA: Real Time Measurement of Main Parameters
EVSE: Safety Test for Electric Car Charging Stations
7 Operations with the Memory
Saving Measurements
Recalling Measurements and Deleting the Memory
Anomalous Situations
8 Connecting the Instrument to a Pc or Mobile Devices
Connection to Ios/Android Devices through Wifi
9 Use of Strap Set
10 Maintenance
General Information
Replacement of the Batteries
Cleaning the Instrument
End of Life
11 Technical Specifications
Technical Characteristics
Reference Guidelines
General Characteristics
Environment
Environmental Conditions for Use
Accessories
12 Service
Warranty Conditions
13 Theoretical
Continuity of Protective Conductors
Insulation Resistance
Checking Circuit Separation
Test on Differential Switches (RCD)
Verify of the Breaking Capacity of Protection Devices
Verify of Protection against Indirect Contacts in TN Systems
No Trip Test in TN Systems
Verify of Protection against Indirect Contacts in TT Systems
Verify of Protection against Indirect Contacts in IT Systems
Verify of Protection Coordination L-L, L-N and L-PE
Verify of the Protection against Short Circuits - Test I2T
Verification of Voltage Drop on Main Lines
Measurement of Earth Resistance in TN Systems
Voltage and Current Harmonics
Presence of Harmonics: Causes
Presence of Harmonics: Consequences
Calculation of Powers and Power Factors
Advertisement
Quick Links
1
Rcd: Test on Differential Switches
2
Loop: Line Impedance/Loop and Overall Earth Resistance
3
Earth: Measurement of Earth Resistance
4
3-Wire or 2-Wire Earth Measurement and 4-Wire Ground Resistivity
Download this manual
Copyright HT ITALIA 2020
Release EN 5.02 - 14/09/2020
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the MACROEVTEST and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for HT MACROEVTEST
Test Equipment HT G Series User Manual
(164 pages)
Test Equipment HT MACROTESTG3 User Manual
(164 pages)
Test Equipment HT GroundTest M71 User Manual
(26 pages)
Test Equipment HT MPP300 User Manual
(28 pages)
Test Equipment HT MT-300 User Manual
(164 pages)
Test Equipment HT PV-ISOTEST User Manual
(40 pages)
Test Equipment HT COMBI521 User Manual
(144 pages)
Test Equipment HT QuickLAN 6055 User Manual
(52 pages)
Test Equipment HT EV-TEST100 User Manual
(10 pages)
Test Equipment HT EQUITEST 5071 User Manual
(44 pages)
Test Equipment HT FULLTEST 3 User Manual
(20 pages)
Test Equipment HT FULLTEST3 User Manual
(100 pages)
Test Equipment HT EASYTEST User Manual
(112 pages)
Test Equipment HT PVCHECK Manual
(56 pages)
Test Equipment HT FULLTEST 3 User Manual
(92 pages)
Test Equipment HT EQUITEST User Manual
(88 pages)
Summarization of Contents
Precautions and Safety Measures
Preliminary Instructions
Instrument design, usage conditions, safety rules, accessories, battery installation, and test lead connection checks.
During Use
Recommendations for safe operation, including disconnecting leads, avoiding touching terminals, and proper current measurement.
After Use
Instructions for turning off the instrument and removing batteries for long-term storage.
Definition of Measurement (Overvoltage) Category
Explanation of measurement categories (I, II, III, IV) based on installation type and overvoltage levels.
General Description
Foreword
Introduction to the Gx Series models and an overview of instrument functions.
Instrument Functions
Detailed description of the instrument's capabilities and tests it can perform.
Preparation for Use
Initial Checks
Procedure for checking instrument for damage, verifying package contents, and contacting dealer for anomalies.
Instrument Power Supply
Information on battery types, charging, and the AutoPower OFF function.
Nomenclature
Instrument Description
Identification and description of the instrument's front, upper, and side parts, including keys and connectors.
Keyboard Description
Detailed explanation of each key on the instrument's keyboard and their functions.
Display Description
Description of the instrument's TFT LCD display, including resolution, touch screen, and information shown.
General Menu
Instrument Settings
Overview of available instrument settings, including language, system, operator name, and date/time.
Language
Procedure for selecting the system language for the instrument's interface.
Reference Country
Setting the reference country, which affects LOOP, NoTrip, and EARTH measurements.
System
Setting electrical system type, mains frequency, contact voltage limits, and rated voltage for calculations.
Operating Instructions
RPE: Continuity of Protective Conductors
Instructions for measuring continuity of protective and equipotential conductors according to standards.
MΩ: Measurement of Insulation Resistance
Procedure for measuring insulation resistance between active conductors and earth, adhering to standards.
RCD: Test on Differential Switches
Procedure for testing differential switches (RCDs) of various types and settings, complying with standards.
LOOP: Line Impedance/Loop and Overall Earth Resistance
Measuring line impedance, fault loop impedance, and prospective short-circuit current.
SEQ: Phase Sequence and Phase Concordance Test
Testing phase sequence and concordance using one or two lead measurements.
LEAKAGE: Leakage Current Measurement
Measuring leakage current using an external clamp (HT96U accessory).
EARTH: Measurement of Earth Resistance
Performing earth resistance measurements using 3/2-wire methods and ground resistivity with 4-wire.
AUX: Measure of Ambient Parameters via External Probes
Measuring ambient parameters like temperature, illuminance, and humidity using external probes.
ΔV%: Voltage Drop of Main Lines
Calculating and verifying voltage drop on main lines, comparing it with limit values.
AUTO TEST: Automatic Test Sequence (NoTrip, RCD, MΩ)
Performing an automatic sequence of NoTrip, RCD, and insulation resistance tests.
PQA: Real Time Measurement of Main Parameters
Performing real-time measurements of voltage, current, powers, and power factors.
EVSE: Safety Test for Electric Car Charging Stations
Performing safety tests on EVSE systems using the EV-TEST100 adapter.
Operations with the Memory
Saving Measurements
Procedure for saving measurements, managing markers, and adding user comments.
Recalling Measurements and Deleting the Memory
Recalling saved measurements, modifying comments, and deleting measurement data.
Connecting the Instrument to a PC or Mobile Devices
Connection to iOS/Android Devices Through WiFi
Connecting instrument to smartphones/tablets via WiFi for data transfer using HTAnalysis APP.
Use of Strap Set
Use of Strap Set
Instructions for assembling and attaching the optional strap set for carrying the instrument.
Maintenance
General Information
General recommendations for instrument usage, storage, and environmental conditions.
Replacement of the Batteries
Step-by-step guide for safely replacing the instrument's batteries.
Technical Specifications
Technical Characteristics
Detailed technical specs including voltage, frequency, RPE, insulation, loop, and first fault current ranges.
Reference Guidelines
List of reference standards and directives (IEC/EN, EMC, LVD, RoHS) applicable to the instrument.
General Characteristics
General characteristics of the instrument, including mechanical, power supply, display, memory, and connectivity.
Environment
Environmental conditions for use and storage, including temperature, humidity, and altitude.
Service
Warranty Conditions
Details on warranty coverage, exclusions, and manufacturer responsibilities.
Service
Procedure for contacting After-sales Service and returning the instrument for repair.
Theoretical Appendixes
Continuity of Protective Conductors
Theoretical explanation and purpose of testing continuity of protective and equipotential conductors.
Insulation Resistance
Theoretical explanation of insulation resistance testing, including parts to check and allowable values.
Test on Differential Switches (RCD)
Purpose and theory behind testing differential switches (RCDs) for correct operation and tripping times.
Verify of Protection Against Indirect Contacts in TN Systems
Theoretical basis for verifying protection against indirect contacts in TN systems within specified time limits.
Voltage and Current Harmonics
Explanation of voltage and current harmonics, their representation, and the THD index.
Calculation of Powers and Power Factors
Formulas for calculating powers (active, reactive, apparent) and power factors in single and three-phase systems.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the MACROEVTEST and is the answer not in the manual?
Questions and answers