AUMA GS 250.3 Manual

AUMA GS 250.3 Manual

Gearboxes, sfc version

Advertisement

Gearboxes
GS 50.3
GK 10.2
SFC version
Manual
GS 250.3
GK 40.2
Functional safety

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GS 250.3 and is the answer not in the manual?

Questions and answers

Summary of Contents for AUMA GS 250.3

  • Page 1 Gearboxes GS 50.3 GS 250.3 GK 10.2 GK 40.2 SFC version Manual Functional safety...
  • Page 2: Table Of Contents

    The present document informs about the actions required for using the device in safety-related systems in accordance with IEC 61508 or IEC 61511. Reference documents: exida report no. AUMA 15/10-108 R014 and AUMA 12/02-079 R007 Operation instructions (Assembly, commissioning) and Technical data for gearbox Reference documents are available on the Internet at: http://www.auma.com.
  • Page 3: Terminology

    Gearboxes Terminology Terminology IEC 61508-4, Functional safety of electrical/electronic/programmable electronic Information sources safety-related systems Part 4: Definitions and abbreviations IEC 61511-1, Functional safety - Safety instrumented systems for the process industry sector Part 1: Framework, definitions, system, hardware and software requirements 1.1.
  • Page 4 Gearboxes Terminology Periodic test performed to detect dangerous hidden failures in a safety-related system Proof test so that, if necessary, a repair can restore the system to an "as new" condition or as close as practical to this condition. Mean time to restoration once a failure has occurred. Indicates the expected mean MTTR (Mean Time To time to achieve restoration of the system.
  • Page 5: Application And Validity

    SIL version may be used. SFC stands for “Safety Figure Calculated”. This desig- nation identifies AUMA products for which safety figures were calculated on the basis of FMEDA from field data and generic data (for detailed information refer to <Determ- ination of the figures>).
  • Page 6: Architecture, Configuration And Applications

    3.3. Protection against uncontrolled operation (self-locking/brake) For self-locking AUMA gearboxes, it can be assumed that a load up to maximum torque will not result in uncontrolled operation from valve standstill due to valve torque load. Consequently, in these cases, further protection against uncontrolled operation is not imperatively required.
  • Page 7 Gearboxes Architecture, configuration and applications Enclosure protection Corrosion protection Ambient temperature Vibration resistance If the actual ambient temperatures exceed an average of +40 °C, the lambda values have to be incremented by a safety factor.
  • Page 8: Safety Instrumented Systems And Safety Functions

    Please note that safety figures only include the gearbox. Further components (e.g. Information integrity of external controls, actuators, valves ..) are not considered with the AUMA safety figures related to this product.
  • Page 9: Installation, Commissioning And Operation

    Gearboxes Installation, commissioning and operation Installation, commissioning and operation Installation and commissioning have to be documented by means of an assembly Information report and an inspection certificate. Installation and commissioning may only be performed by authorised personnel who have been trained on functional safety. 5.1.
  • Page 10: Tests And Maintenance

    This validation must include at least the tests referred to in chapters <Safety equipment: check> and <Proof test (verification of safe gearbox function>. In case a fault is detected during maintenance, this must be reported to AUMA Riester GmbH & Co. KG.
  • Page 11: Safety-Related Figures

    Gearboxes Safety-related figures Safety-related figures 7.1. Determination of the safety-related figures The calculation of the safety-related figures is based on the indicated safety functions. Experience data and data taken from the exida database for mechanical components were used for hardware assessment. The PFD calculation should always be performed individually for each system using the parameters and conditions applicable for the respective system.
  • Page 12: Sil Declaration Of Conformity (Example)

    Gearboxes SIL Declaration of Conformity (example) SIL Declaration of Conformity (example)
  • Page 13 Gearboxes SIL Declaration of Conformity (example)
  • Page 14 Gearboxes...
  • Page 15 Gearboxes...
  • Page 16: Index

    Gearboxes Index Index Safe failure fraction (SFF) Safety function Safety functions Ambient conditions Safety instrumented function Architecture (SIF) Safety instrumented system (SIS) Brake Safety-related system Self-locking Commissioning Service conditions Configuration Setting Standards Declaration of Conformity Decommissioning Device types Tests Diagnostic coverage (DC) T proof Type of duty Figures, safety-related...
  • Page 17: Addresses

    AUMA Finland Oy AUMA Polska Sp. z o.o. FI 02230 Espoo PL 41-219 Sosnowiec Tel +358 9 5840 22 Tel +48 32 783 52 00 AUMA Riester GmbH & Co. KG auma@auma.fi biuro@auma.com.pl www.auma.fi www.auma.com.pl Location Muellheim DE 79373 Muellheim AUMA France S.A.R.L.
  • Page 18 AUMA worldwide AUMA South Africa (Pty) Ltd. Mikuni (B) Sdn. Bhd. Mustafa Sultan Science & Industry Co LLC ZA 1560 Springs BN KA1189 Kuala Belait OM Ruwi Tel +27 11 3632880 Tel + 673 3331269 / 3331272 Tel +968 24 636036 aumasa@mweb.co.za...
  • Page 19 AUMA worldwide...
  • Page 20 AUMA Riester GmbH & Co. KG P.O. Box 1362 DE 79373 Muellheim Tel +49 7631 809 - 0 Fax +49 7631 809 - 1250 info@auma.com www.auma.com Y008.167/003/en/1.20 For detailed information on AUMA products, refer to the Internet: www.auma.com...

Table of Contents

Save PDF