Rosemount 1496 Installation & Operation Manual

Rosemount 1496 Installation & Operation Manual

Orifice plate;orifice flange union

Advertisement

Reference Manual
00809-0100-4792, Rev CA
August 2010
Rosemount 1495 Orifice Plate, 1496 Orifice
Flange Union
Installation & Operation Manual
Rosemount 1496
Rosemount 1495
Orifice Flange Union
Orifice Plate
www.rosemount.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1496 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Section 1 Introduction
Using This Manual
Explains how to navigate and utilize the manual's content effectively.
Service Support
Provides contact information for technical assistance and support.
Product Recycling/Disposal
Information and guidelines for responsible product disposal.
Section 2 Installation Location and Orientation
Safety Messages
Critical safety precautions to ensure safe installation practices.
Installation Checklist
A step-by-step guide to complete the installation process.
Receiving and Inspection
Procedure for inspecting and verifying received products.
Installation Configuration
Proper orientation guidelines for different fluid types.
Straight Run Requirements
Guidelines for required pipe lengths around flow devices.
Section 3 Hardware Installation for Rosemount 1495 Orifice Plate
1495 Types
Overview of the different Rosemount 1495 Orifice Plate models.
Bore Types
Details on various orifice bore configurations available.
Installation Instructions
Step-by-step instructions for installing the 1495 Orifice Plate.
1495 Dimensional Drawings
Technical drawings illustrating dimensions of 1495 Orifice Plates.
1495 Weights (Estimated)
Estimated weight data for various 1495 Orifice Plate configurations.
Section 4 Hardware Installation for Rosemount 1496 Flange Union
1496 Types
Overview of the different Rosemount 1496 Flange Union models.
1496 Flange Union Components
Identification and description of 1496 Flange Union parts.
Installation Instructions
Step-by-step instructions for installing the 1496 Flange Union.
1496 Dimensional Drawings
Technical drawings illustrating dimensions of 1496 Flange Unions.
Appendix A Specifications and Reference Data
Functional Specifications
Details on operating ranges, flow conditions, and limitations.
Physical Specifications
Information on pipe schedules, dimensions, and materials.
Sizing and How to Order
Guidance for selecting and ordering the correct product configurations.
Rosemount 1495 Configuration
Details on ordering options for the 1495 Orifice Plate.
Rosemount 1496 Configuration
Details on ordering options for the 1496 Flange Union.
Appendix B Recommended Installation Requirements
Recommended Straight Run Requirements
Tables specifying required pipe lengths for optimal flow measurement.
Bolt Torque Recommendations
Class 300# Non-Asbestos Flat Gasket Torque
Typical bolt torque values for Class 300 flanges with flat gaskets.
Class 600# Spiral Wound Gasket Torque
Typical bolt torque values for Class 600 flanges with spiral gaskets.
Class 900# Spiral Wound Gasket Torque
Typical bolt torque values for Class 900 flanges with spiral gaskets.
Class 1500# Spiral Wound Gasket Torque
Typical bolt torque values for Class 1500 flanges with spiral gaskets.
Class 2500# Spiral Wound Gasket Torque
Typical bolt torque values for Class 2500 flanges with spiral gaskets.
Appendix C Calculation Data Sheet
General Data
Customer and project-specific information for calculations.
Product Description
Details of the orifice plate and flange union for calculation.
Input Data
Process fluid properties and operating conditions for calculations.
Calculated Data
Results from flow calculations based on input parameters.

Table of Contents