Manual. The manual and this guide are also available electronically on EmersonProcess.com/Rosemount. If the Rosemount 1195 Integral Orifice was ordered assembled to a Rosemount Pressure Transmitter, refer to the following Quick Start Guides for information on configuration and hazardous locations certifications: ...
Quick Start Guide June 2016 1.0 Rosemount 1195 Integral Orifice Assembly View Figure 1. Traditional Body A. Manifold E. Transmitter B. Gaskets F. Rosemount 1195 traditional body C. Studs G. Traditional orifice plate D. Nuts 1. Transmitter and housing are shown for clarity purposes - only supplied if ordered.
G. Enhanced support orifice plate D. Nuts 2.0 Location and orientation Install the Rosemount 1195 Integral Orifice in the correct location within the piping branch to prevent inaccurate measurement caused by flow disturbances. 2.1 Straight pipe length Use the upstream (U) and downstream (D) lengths provided below in conjunction with figures below to determine the appropriate upstream (U) and downstream (D) pipe lengths.
Page 5
Quick Start Guide June 2016 Straight run requirements Figure 3. Reducer (2 d to d over a length of 1.5 d to 3 d) Figure 4. Single 90° Bend Flow from One Branch Figure 5. Two or More 90° Bends in Same Planes Figure 6.
Page 6
June 2016 Quick Start Guide (0.5 d to d over a length of d to 2 d) Figure 8. Ball/Gate Valve Fully Open Table 1. Straight Run Requirements (in Pipe Diameters) Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figures 3–8 β...
Quick Start Guide June 2016 3.0 Primary element orientation Figure 9. Rosemount 1195 Flowmeter Orientation with Traditional Style Manifold Gas (horizontal) Gas (vertical) Liquid (horizontal) Liquid (vertical) Steam (horizontal) Steam (vertical) A. 90° recommended zone D. 360° recommended zone B. Vertical plane E.
Page 8
June 2016 Quick Start Guide Figure 10. Rosemount 1195 Flowmeter Orientation with Flange by Flange Manifold Gas (horizontal) Gas (vertical) Liquid (horizontal) Liquid (vertical) Steam (horizontal) Steam (vertical) A. 120° recommended zone D. 360° recommended zone B. Horizontal plane E. Block valves C.
1. Studs and nuts should be tightened to specification in two to three steps following a cross pattern. 2. Never reuse gaskets. Always replace gaskets after disassembly to ensure proper seal. Figure 11. Rosemount 1195 Assembly Fastener Naming Convention Traditional body...
Page 10
Figure 12. Recommended Support Locations for Installation A. Support B. No step 5. Once the Rosemount 1195 is installed ensure that it is supported properly and take precautions to ensure that it is not used as a step. Refer to Figure 12...
Quick Start Guide June 2016 5.0 Preparing for operation Note Serious injury can occur by opening the valves when the pipes are pressurized. Do not bleed or vent process fluid if it is toxic or harmful to health or environment. 5.1 Direct mount 450 °F (232 °C) or less Liquid applications 1.
Page 12
June 2016 Quick Start Guide 5.2 Remote mount Gas applications-transmitter located above Rosemount 1195 Taps 1. Pressurize line. 2. Open equalizer valve on transmitter manifold. 3. Open high and low side transmitter manifold valves. 4. Open drain/vent valves on transmitter manifold to ensure no liquids are present.
Page 13
Quick Start Guide June 2016 Liquid applications-transmitter located below Rosemount 1195 Taps 1. Pressurize line. 2. Open equalizer valve on transmitter manifold. Close equalizer valve at integral orifice, if one is used. 3. Open high and low side transmitter manifold valves and high and low block valves at integral orifice.
Page 14
June 2016 Quick Start Guide Figure 14. Remote Steam and Liquid Service A. Vent B. High valve C. Equalizer valve D. Vent valves E. Low valve 1. Applicable to both body assemblies.
6.2 European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found on the at EmersonProcess.com/Rosemount. A hard copy may be obtained by contacting our local sales office. European Pressure Equipment Directive (PED) (97/23/EC) Refer to EC declaration of conformity for conformity assessment.
Page 16
June 2016 Quick Start Guide Figure 15. Rosemount 1195 Declaration of Conformity...
Page 19
Quick Start Guide June 2016 Rosemount 1195 China RoHS 表 表 格 含有 管控物 超 的部件型号列表 Table 1B: List of Rosemount 1195 Parts with China RoHS Concentration above MCVs 有害物 Hazardous Substances 部件名称 多 Part Name 六价 多 汞 Polybrominated...
Page 20
Jebel Ali Free Zone - South 2 The Emerson logo is a trademark and service mark of Emerson Dubai, United Arab Emirates Electric Co. Annubar, Rosemount and Rosemount logotype are trademarks of +971 4 8118100 Emerson Process Management. +971 4 8865465 All other marks are the property of their respective owners.