Delivery inspection
After removing the carton, carefully inspect the generator for
any damage that may have occurred during shipment.
iMPortant: If loss or damage is noted at time of delivery,
have the person(s) making delivery note all damage on the
freight bill and affix his signature under the consignor's
memo of loss or damage. If loss or damage is noted after
delivery, separate the damaged materials and contact the
carrier for claim procedures. Missing or damaged parts are
not warranted.

shipment contents

the home generator system is supplied with:
• Home generator
• Pre-attached mounting pad
• Fully-serviced oil/lubricating system
• Flexible fuel hook-up hose
• Installation and start-up manual
• Operator's manual
• Engine operator's manual
• Installation checklist
• Access door keys
• Spare 15 Amp ATO-type fuse
• Two-pole control panel connector
• Ten-pole control panel connector

Generator Location

Before installing the generator, consult with the homeowner
and convey the following guidelines, which may affect the
desired installation location.
WarninG: Exhaust heat/gases can ignite combustibles or
structures causing a fire.
DO NOT install the generator closer than 5 feet (1.5m) from any
combustibles or structures with combustible walls having a fire
resistance rating of less than 1 hour.
8
• Oil drain tray
• Touch up paint
• Roof hardware
• Fuel conversion kit
• Remote LED indicator kit (LED/plate/screws)
not supplied:
• Starting battery (see page 19)
• Connecting wire and conduit
• Fuel supply valves/plumbing
• Crane, lifting straps, chains or cables
• Hole punches for 16ga steel
• Torque screwdriver, 5 to 50 inch-pound range
• Voltage/frequency meter
WarninG: Running engine gives off carbon monoxide, an
odorless, colorless, poison gas.
Breathing carbon monoxide can cause headache, fatigue,
dizziness, vomiting, confusion, seizures, nausea, fainting
or death.
Operate generator ONLY outdoors.
Install a battery operated carbon monoxide alarm near
the bedrooms.
Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes, or other openings.

Advertisement