Oakton TDS 6 Instruction Manual

Oakton TDS 6 Instruction Manual

Hand-held conductivity/tds meter

Advertisement

Instruction Manual
CON 6/TDS 6
Hand-held Conductivity/TDS Meter
68X243618
Technology Made Easy ...
ver. 0 11/02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TDS 6 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Display and Keypad Functions
Display Overview
Details the meter's LCD screen, including primary display and annunciators.
Keypad Functions
Explains the function of each key on the meter's keypad and their different modes of operation.
Preparation and Setup
Rubber Boot Installation
Instructions for attaching and detaching the protective rubber boot for the meter.
Battery Installation
Procedure for opening the battery compartment and inserting the correct batteries.
Battery Replacement
Guidance on replacing batteries when the low battery indicator is displayed.
Conductivity Electrode Details
Information on the conductivity/TDS electrode, its materials, and proper immersion.
Probe Connection
Steps for connecting the conductivity probe and temperature sensor to the meter.
Powering On the Meter
Describes the power-on sequence and initial display parameters of the meter.
Switching Measurement Modes
How to switch between Conductivity/TDS and Temperature measurement modes using the MODE key.
Calibration Procedures
Calibration Information
Key information regarding meter calibration, including ranges and solution recommendations.
Preparing for Calibration
Steps to prepare the meter and ensure accuracy before starting the calibration process.
Auto vs. Manual Calibration
Explains the choice between automatic and manual calibration methods for the meter.
Automatic Conductivity Calibration
Step-by-step guide for performing automatic conductivity calibration using standard solutions.
Manual Calibration
Instructions for manual calibration using custom or non-standard calibration solutions.
Temperature Calibration
Procedure for calibrating the meter's temperature sensor for accurate readings.
Taking Measurements
Automatic Temperature Compensation (ATC)
How to use the meter with automatic temperature compensation for accurate readings.
Manual Temperature Compensation
Procedure for manual temperature compensation when ATC is not used.
Performing Measurements
Step-by-step guide on how to take conductivity and TDS measurements.
Manual Ranging
Explanation of how to manually select measurement ranges for optimal readings.
Hold Function
How to freeze the displayed measurement for delayed observation.
Advanced Setup Options
Advanced Setup Overview
Introduction to the advanced setup mode and how to access its features.
Cell Constant Selection
How to select the appropriate cell constant (K) for different measurement ranges.
Automatic Calibration Setup
Setting the meter for automatic calibration mode for conductivity measurements.
TDS Factor Setting
Configuring the TDS conversion factor for accurate TDS readings on the TDS 6 meter.
Temperature Coefficient Adjustment
Setting the temperature coefficient for accurate conductivity compensation.
Normalization Temperature Setup
Selecting the standard temperature for normalizing conductivity measurements (20°C or 25°C).
Single-Point Calibration Setup
Configuring the meter for single-point calibration across all ranges.
Restore Factory Defaults
How to reset all meter settings and calibration data to factory defaults.