DigiTech Artist GSP-2101 Owner's Manual page 88

Studio tube preamp / multi-effects processor
Hide thumbs Also See for Artist GSP-2101:
Table of Contents

Advertisement

Section 7 - Other Utilities
The following diagram shows exactly what happens during the course of a seamless Program
change. The example settings are: HOLD TIME = 1.4 seconds; RAMP TIME = 2.6 seconds.
From 0 seconds to 2 seconds, the currently selected Program runs normally using S-DISC 1. At 2
seconds, a Program change message is received, initiating HOLD TIME for the original Program
and ramping the S-DISC 1 inputs to zero. Simultaneously, the new Program is loaded into S-
DISC 2 and begins running. At 3.4 seconds (1.4 seconds from the Program change), RAMP
TIME is initiated, which smoothly ramps the original Program level down to inaudibility over
the course of 2.6 seconds.
It is significant to note that, between the 2 and 6 second marks, BOTH PROGRAMS ARE
RUNNING AT THE SAME TIME. No other device currently available has this ability.
NOTE: Be sure to set up your own Programs this way, as unnecessarily long HOLD and RAMP
TIMEs reduce the speed and efficiency of Program changes.
The Seamless Program Change menu can be reached using the following procedure:
• Use the Program [UP] or [DOWN] keys to select the Program you want to change.
• Press [UTILITY] once. The display reads:
• Press [NEXT] twice. The display reads:
86
HOLD TIME = 1.4 seconds
RAMP TIME = 2.6 seconds
40 dB
20 dB
Program Change
0 dB
Hold Time
20 dB
40 dB
60 dB
80 dB
00 dB
20 dB
0 sec
1 sec
2 sec
¡Output Mode: Stereo
™Foot Controller
Seamless Program 99
¡Hold Time:
™Ramp Time:
Original Program
New Program
Decaying (no signal)
3 sec
4 sec
5 sec
6 sec
5.0 Sec
0.0 Sec
GSP-2101 Artist Owner's Manual

Advertisement

Table of Contents
loading

Table of Contents