3.
Go to the Windows Task Manager and end the hpmsafcvds task. (Right click the Windows
Taskbar, and select Task Manager. Click the Processes tab, click the hpmsafcvds task, click
End Process, and close the Task Manager.)
4.
Restart the client application.
The delete lun command is supported, but only the last logical drive of an array can be
deleted. VDS does not recognize the concept of arrays, so it is not readily apparent which
LUN can be deleted.
The hardware provider does not allow simultaneous extension of size with a list of disks. For
example the following command is invalid: extend lun drives=5,6 size=111mb. Use
only one option at a time. Also, the hardware provider will not automatically extend a LUN to its
maximum size when specifying a drive list.
The only Automagic set parameters supported are FTL, MXD, and STS. When using the
STS parameter, you must select one of the available stripe sizes. To list stripe sizes, use the
detail subsytem command.
The maintenance command supports only blinking. Other maintenance options are not
supported, such as SPINUP, SPINDOWN, BEEP, and PING.
The HP MSA FC VDS hardware provider supports HP MPIO Full-Featured DSM for MSA
Active-Active configurations. For MSA Active-Passive configurations, the HP MSA FC VDS
hardware provider supports only HP MPIO Basic DSM, and you must use MPIO management
software to manage MPIO.
Determining current version
To determine your current version of HP MSA HWP software:
1.
Select Windows Start > Settings > Control Panel, and select Add or Remove Programs.
2.
Click HP VDS.
3.
Click Support Information.
Supersedes history
None
Effective date
February 2007
HP StorageWorks Modular Smart Array FC VDS Hardware Provider for Windows 2003 release notes
5

Advertisement

loading

This manual is also suitable for:

353803-b22 - storageworks modular smart array 1000 san starterAd510a - storageworks modular smart array 1500 cs 2u fibre channel san attach controller shelf hard driveAe326a - storageworks modular smart array 1500 san sata starterStorageworks 1000 - modular smart arrayStorageworks 1500cs - modular smart array353803-b22 - storageworks modular smart array 1000 san starter ... Show all