ATS2000/3000 Control
Panel
Installation and
Quick Programming Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATS2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aritech ATS2000

  • Page 1 ATS2000/3000 Control Panel Installation and Quick Programming Guide...
  • Page 2 Aritech is an Interlogix Company © Interlogix B.V. 2001. All rights reserved. No part of this publication may be reproduced, transmitted, stored in a retrieval system, or transmitted in any form, or by any means – electronic, photocopying, recording, or otherwise –...
  • Page 3: Table Of Contents

    Outputs............................5 Siren outputs ..........................6 Output control groups........................6 Door and lift numbering........................6 Technical specifications ..........................6 Specification ATS2000/3000 Main Board (no accessories)............7 Specification External terminals .....................7 Values for end-of-line resistors......................7 Connection diagrams ........................8 Quick Programming Guide ..........................9 Defaulting the panel to factory defaults..................9 Powering up the panel ........................9...
  • Page 4: Control Panel

    (central station or dialler modem) or J18 (serial port (RS232 PC). Tx1: Red LED flashes when data is being sent from the panel to a device connected to the PTT line (J15/J16) or J18 serial port. ATS2000/3000 Installation and Quick Programming Guide...
  • Page 5: Cabling

    Preferred data cable type is Belden 8723 (2 pair twisted). TERM link fitted (last device on local databus) Earth lug to connect shield Any data gathering panel like ATS1201. See: System databus connection and Earthing details on page 4 ATS2000/3000 Installation and Quick Programming Guide...
  • Page 6: System Databus Connection

    The safety earth of this building has to be checked by a licensed contractor. Mains power with local earth Building 1 Mains power connector Building 2 System databus Device in metal housing Earth lug Device in plastic housing ATS2000/3000 Installation and Quick Programming Guide...
  • Page 7: Mounting

    DGP address cannot be used. The ATS2000 and ATS3000 will allow only for 32 (ATS2000) or 64 zones (ATS3000) to be programmed The output numbers can be used if output controllers are with a zone type other then 0.
  • Page 8: Siren Outputs

    630mA, fast 20x5 * F2 (Switched aux. Power) only available on ATS3000. ** Mains Fuse is part of the mains terminal block. WARNING! Before removing the mains fuse, mains power must be disconnected (see page 2)! ATS2000/3000 Installation and Quick Programming Guide...
  • Page 9: Specification Ats2000/3000 Main Board (No Accessories)

    1. Specification ATS2000/3000 Main Board (no accessories) Description: Max. output current: Max. 2 Amp Current consumption: 200 mA nominal Default end of line resistors: 4,7 kΩ, 5 %, 0,25W Max.number zones to program 32 (ATS2000) or 64 (ATS3000) Max number of areas to assign to zones...
  • Page 10: Connection Diagrams

    K i l l F a c t o r y d e f a u l t c o n t r o l p a n e l w h e n s h o r t e d ATS2000/3000 Installation and Quick Programming Guide...
  • Page 11: Quick Programming Guide

    The Master LCD Arming Station (RAS 1) should have all area LED ON and the LCD should display 5. Entering the programming menu to the name "Aritech Systems" followed by details of program the system the Arming Station software version.
  • Page 12: Changing Parameters In The Programming (Examples)

    6. Press Clear to exit. The Manager code is now options will have the standard values. changed. For other options refer to the ATS2000/3000/4000 7. Programming sequences programming guide The following can be used as a guide for the order in which records can be programmed when setting up a basic system.
  • Page 13: Programming Map

    63. Entry check no arm check 20. Zone to Event Flag 24-hr 42. Fire door w. code Entry/Exit holdoff reporting 21. Firedoor with usercode 43. Disarm zone to Event Flag 64. acces no arm check holdoff reporting ATS2000/3000 Installation and Quick Programming Guide...
  • Page 14 13. Reset from RAS without code 14. Alarm group restrictions to disarm only 15. Enable entry/exit buzzers 16. Timed lockout 0. Standard 1. Door Controller 4. Data Panels 1. DGP to be polled 1. DGP type 2. Lift Controller ATS2000/3000 Installation and Quick Programming Guide...
  • Page 15 16. Individual test mode time 17. Door unlock time 18. Testing event flag 19. Siren cut-out time 20. Mains fail delay time 21. Delay reporting of Entry/Exit alarms 22. A to B alarm delay (ACPO) ATS2000/3000 Installation and Quick Programming Guide...
  • Page 16 4. Enter the system account number 5. Enter the area account number 6. Use BELL modem tones for SIA 7. Dual reporting 8. Audio Listen In 9. Disable reporting of inhibits 10. Use analog ISDN interface ATS2000/3000 Installation and Quick Programming Guide...
  • Page 17 7. Door open command starts shunt 8. Shunt zone when disarmed 9. Shunt zone when armed 10. Cancel Door event flag 11. Zone holds event flag at 2 seconds 12. Entry/exit shunting 13. Log door open/close ATS2000/3000 Installation and Quick Programming Guide...
  • Page 18 1. Select battery test program 1. Battery test frequency 2. Start battery test 3. Run battery test 1. Select battery test 1. Manual battery test 2. Battery test report 3. Select DGP n° for battery test ATS2000/3000 Installation and Quick Programming Guide...
  • Page 19 5. Always terminate direct line 6. Enable network commands 42. Reporting class DB 1. Select the reporting class 1. Select the class condition 43. Test calls 1. Start test call 2. Test call interval 3. Extend test call ATS2000/3000 Installation and Quick Programming Guide...
  • Page 20 5110 - 0b...