CONTENTS Delivery set ................................................7 Brief description ..............................................7 Operation guidelines ............................................7 Designation key ..............................................8 Mounting and setup ............................................9 Electronic system operation algorithm ....................................10 Maintenance................................................12 Troubleshooting ..............................................12 Storage and transportation regulations ....................................13 Manufacturer’s warranty ..........................................14 This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
Page 3
This unit is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety.
Page 4
Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances. The appliance may adversely affect the safe operation of appliances burning gas or other fuels (including those in other rooms) due to back flow of combustion gases.
Page 5
All operations described in this manual must be performed by qualified personnel only, properly trained and qualified to install, make electrical connections and maintain ventilation units. Do not attempt to install the product, connect it to the mains, or perform maintenance yourself. This is unsafe and impossible without special knowledge.
Page 6
Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, insecticides, etc. Do not close or block the intake or extract vents in order to ensure the efficient air flow. Do not sit on the unit and do not put objects on it.
Page 7
The Company reserves the right to modify the technical characteristics, design, or configuration of its products at any time in order to incorporate the latest technological developments. Never touch the unit with wet or damp hands. Never touch the unit when barefoot. BEFORE INSTALLING ADDITIONAL EXTERNAL DEVICES, READ THE RELEVANT USER MANUALS.
DELIVERY SET Fan - 1 item Screws with dowels - 4 items Plastic screwdriver - 1 item (only for the models with a timer) Operation manual - 1 item Packing box - 1 item BRIEF DESCRIPTION The product is an axial fan for exhaust ventilation of small and medium-sized premises heated in winter. The design of the fan may include a back valve that prevents air from flowing into the room when the fan is off.
DESIGNATION KEY 100 Ace -I V L (220 V/60 Hz) Power supply parameters _ — 220-240 V/50 Hz by default (220 V/60 Hz) — 220 V/60 Hz Motor modifications _ — single-speed motor Duo — two-speed motor L — motor with ball bearings 12 —...
MOUNTING AND SETUP The fan is designed for wall (with the motors on ball and slide bearings) or ceiling (with the motors on ball bearings only, L option) mounting and can be used for direct outdoor air exhaust through a round duct or a duct system. In case of installation through a duct system, select the duct cross section in accordance with the fan size (Fig.
Page 11
Connection diagram terminal key: — line — external switch — neutral — automatic circuit breaker — timer control line WARNING! Fans rated for 12 V (as specified on the fan packing and casing) must be connected to ~12 V electric mains only! WARNING! The power cable may only be laid through the hole in the casing provided by the manufacturer (Fig.
ELECTRONIC SYSTEM OPERATION ALGORITHM The T model fans equipped with a timer are activated by control voltage application to input terminal by an external switch (e.g. indoor light switch). Upon control voltage removal the fan continues to operate for the period of time set by the timer within the range from 2 to 30 minutes.
Page 13
THE TIMER BOARD IS UNDER MAINS VOLTAGE. MAKE SURE THE FAN IS COMPLETELY DISCONNECTED FROM THE POWER MAINS BEFORE ADJUSTING — To adjust the fan activation delay time, turn the potentiometer knob clockwise (+) or counter-clockwise (-) which sets the activation delay time within the range from 0 to 2 minutes. —...
MAINTENANCE DISCONNECT THE UNIT FROM POWER MAINS BEFORE ANY MAINTENANCE OPERATIONS! To clean the unit from any dust and dirt which may accumulate on the surfaces, use a soft cloth and a brush soaked in a mild detergent solution. Avoid spilling liquid on the electrical components. Wipe the cleaned surfaces dry.
STORAGE AND TRANSPORTATION REGULATIONS • Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range from +5 ˚C to +40 ˚С and relative humidity up to 70 %. • Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and sealing deformation.
MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/ EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
Page 17
• Replacement and use of any assemblies, parts and components not approved by the manufacturer. • Unit misuse. • Violation of the unit installation regulations by the user. • Violation of the unit control regulations by the user. • Unit connection to power mains with a voltage different from the one stated in the user's manual. •...
Page 18
Dimensions, mm 100 Ace 151 128 115 100 Ace One ø D 125 Ace 124 180 158 122 ˚ ˚ ...2...
Page 19
CAUTION! The decorative front panel is available separately.
Page 20
100/125 100/125 T 100/125 V/VT 100/125 T/VT Fan does not run Contact of S1 switch or pull cord switch is CLOSED Fan runs Contact of S1 switch or pull cord switch is OPENED Activation of turn-off delay timer (2-30 minutes)
Page 21
100/125 T1 Fan does not run Contact of S1 switch or pull cord switch is CLOSED Activation of turn-on delay timer (0-2 minutes) Switch is OFF during countdown of turn-on delay timer Fan runs Contact of S1 switch or pull cord switch is OPENED Activation of turn-off...
Page 22
100/125 TH 100/125 VTH Fan does not run Contact of S1 switch or pull cord switch is CLOSED Humidity exceeds set point Fan runs Contact of S1 switch or pull cord switch is OPENED Fan runs Humidity is below set point Activation of turn-off...
Page 23
100/125 T1 Duo Fan runs at speed 1 Contact of S1 switch is CLOSED Activation of turn-on delay timer (0-2 minutes) Fan runs at speed 2 Contact of S1 switch is OPENED Activation of turn-off delay timer (2-30 minutes)
Page 24
100/125 TH Duo Fan runs at speed 1 Contact of S1 switch is CLOSED Humidity exceeds set point Activation of turn-on delay timer (45 seconds) The contact of S1 switch is OPENED during turn-on delay timer operation Fan runs at speed 2 Humidity is below set point Fan runs at speed 2 Activation of turn-off...
Page 25
100/125 Duo speed 1 and 2 Fan does not run Contact of S1 switch is CLOSED S1 switch in position Fan runs at speed 2 Fan runs at speed 1 Contact of S1 switch is OPENED DO NOT CLOSE CONTACTS S AND L WITH EACH OTHER. THIS MAY LEAD TO PRODUCT DAMAGE...
Page 27
Quality Inspector’s Stamp Seller (name and stamp of the seller) Manufacture Date Purchase Date...
Page 28
Acceptance certificate ____________________________________________________ The fan is recognized as serviceable. V160-2EN-03...