Contents 01 Safety Operation and Notice ..........................Thank you for choosing a RELACART professional wireless microphone system. You have 02 System Performance Feature ..........................joined thousands of other satisfied customers. Our years of professional experience of 03 Receiver Installation Method ..........................
” indicates that dangerous voltage constituting a risk of electric shock is present within this unit. broadcasters and other demanding audio environments. 21. All Relacart products will be afforded one year free maintenance except for man-made damage, such as: — the device is damaged by man-made factors.
Receiver Installation Method Packing List Wireless microphone receiver (HR-30S/HR-31S) *1 Installation: Wireless transmitter ① For better operation the receiver should be at least 3ft (1m). above the ground and at least 3ft BNC Antenna *2 (1m). away from a wall or metal surface to minimize reflections.
Receiver Front Panel Function Introduction Receiver Rear Panel Function Introduction (HR-30S) Power switch: Turn on the receiver of power supply, long press to turn off the receiver. (HR-31S) “SYNC” button: When the infrared frequency window of the receiver and transmitter is aligned, press the “SYNC”...
REMOTE-IN-U485 Connector: 4P cable is used to connect receiver with computer PC/USB connector to realize software control. REMOTE-OUT: 4P cable is used to connect with another HR-30S/HR-31S receiver. (IP for each receiver should be different.) Unbalanced audio output port (dual channel mixed): The 6.3mm port can be connected to the microphone or line input of the device.
Bodypack transmitter Infrared data receiving window (IR): Synchronization of transmitters via IR interface from receiver. Battery cover: Unscrew it can reveal the battery compartment; When installing or replacing, the battery cover must be opened. Battery compartment: Insert 2 fresh 1.5V AA batteries. (Alkaline type is recommended. Please remember to replace both batteries.) Warn: Observe correct polarity as marked inside the battery compartment to avoid damage to the internal electric parts.
Transmitter Battery Installation LCD Window: Liquid crystal display indicates operational frequency/channel, mute, lock status, and battery condition. The transmitter’s “fuel gauge” battery indicator displays a maximum of 4 bar segments. When it leaves 1 bar segment. the batteries should be replaced immediately to ensure continued operation.
2. Press power button on receiver, LCD readouts light and will display in normal after 2-3 the 0dB ~ 50dB (HR-30S) or 0dB ~ 45dB (HR-31S ) by 5dB step. after finish setting seconds. If LCD screen shows two different RF signal range, that means there is please single press SET button to save.
Page 10
Touch “iR” window synchronizing settings from receiver to press the arrow button to choose from 1 to 39 (HR-30S) or 1 to 28 (HR-31S) transmitter. (*HR-30S) channels, after finished the setting please single press SET button to save.
(13) R-LOCK (lock operation): Selecting “R-LOCK”, then touch SET button to enter edit HR-30S Operating menu of the Receiver: mode, touch arrow button, it displays “ON”, if stopping on “ON”, the system enters DISPLY Frequency Channel Switching between the standard Current standard display;...
User-firendly steps 1. After connecting the antenna and the power cable, press the power button to turn on the HR-31S Operating menu of the Receiver: receiver. When the display is lit, the power is turned on successfully. (As shown below) SQELCH 45dB Adjusting the squelch threshold...
Page 13
The searched channel automatically calculates the interference-free frequency. The “RF” light on the The frequency of the transmitter and the receiver are synchronized. When talking with the receiver display is 0 grid. If not, you can repeat this action until a clean channel is found. (As shown microphone, the “AF”...
RWW PC Digital Control Software 1. Instruction: With U-485 USB connector, HR-30S or HR-31S receiver and computer can be connected in RWW is an advanced and powerful digital software. The PC controlling using a Relacart order to use RWW digital control software, to realize control and monitor operation through U-485 connector, to link to HR systems for real time monitored.
RWW software scans RF environments and shows detailed displays of scanned data 1) Equipment Connection from Relacart HR series wireless receivers. Through scanning, potential RF problems A. USB Connector. can be positioned and checked out before they have a chance to affect our sound.
5) DISCONNECTION: 3. After scanning, click “next step” to start counting the frequencies, through this step, RWW Disconnect the operation of wireless microphone systems into RWW control software. software can count out which frequencies are available, and which are not. 4.
Weight : Approximately 1.0Kg Notice: More information about RWW control software operation, Please refer to www.relacart.com to download the presentation video, or you can turn to our professional sales for further information. We will be very glad to help. Thank you!