Recovering The Boot Rom Password; Dealing With Power System Failures; Dealing With Configuration System Failures - 3Com LS-S3610-52P-OVS Installation Manual

S3610 series ethernet switches
Table of Contents

Advertisement

Installation Manual
H3C S3610 Series Ethernet Switches
Enter your choice(0-9):
Select <7> and have the switch reboot. The user password is deleted at the reboot to
allow you access the switch without password.

6.2.2 Recovering the Boot ROM Password

Contact your sales agent for help.

6.3 Dealing with Power System Failures

You can know whether the power system has failed by reading the PWR LED on the
front panel. If the power system is operating normally, the PWR LED is ON. If not, check
that:
The switch power cord is correctly connected.
The power source can work with the switch.

6.4 Dealing with Configuration System Failures

If the switch is operating normally after it is powered up, it displays the start-up
information on the console terminal. If the configuration system has failed, it displays
illegible characters or nothing at all.
I. No information on the terminal
Take these steps to address the problem:
Check that:
The power system is operating normally.
The console cable is connected correctly.
Check that the console cable is in good condition and the terminal
(HyperTerminal for example) parameter settings are correct.
II. Illegible characters on the terminal
Make sure you have set on your terminal (HyperTerminal):
Baud rate = 9600
Data bits = 8
Parity check = none
Stop bits = 1
Flow control = none
Terminal emulation = VT100
Reconfigure the parameters if their values are different.
Chapter 6 Maintenance and Troubleshooting