akira AC-FR30HA Service Manual

Advertisement

Quick Links

Air Conditional
Service Manual
https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html
,
,
,
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AC-FR30HA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for akira AC-FR30HA

  • Page 1 Air Conditional Service Manual https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 2 -2 - MODEL: AC-FR30HA Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 3: Table Of Contents

    -3 - CONTENTS SPECIFICATION............................. 4 APPEARANCE & PART NAME......................5 PANEL & CONTROL FUNCTION......................6 INSTALLATION INSTRUCTION ......................12 EXPLODED VIEW AND PART LIST ....................23 CIRCUIT DIAGRAM ..........................27 TROUBLESHOOTING ......................... 29 Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 4: Specification

    -4 - Model AC-FR30HA Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 5: Appearance & Part Name

    -5 - & & Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 6: Panel & Control Function

    -6 - & & Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 7 -7 - Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 8: Remote Control

    -8 - Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 9 -9 - Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 10 -10 - Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 11 -11 - Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 12: Installation Instruction

    A saline place such as coast. Hot-spring resort. A place full of sulfide gas. A place where there are high frequency machines such as wireless installation, welding machine, medical facility. A place of special environmental condition. Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 13 In directions A, B, C leave open two of the three directions. c. Reserve enough space for installation, maintenance and unit-functioning. Remove as many obstacles as possible nearby. When the air-in surface is facing a wall. When the air0out surface is facing a wall. Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 14: Installation

    Refrigerant pipe (optional) Name capacity (Btu/h) 20000~30000 30000~55000 Liquid side size Ф9.53mm Ф12.7mm Gas side size Ф16mm Ф19mm If there is any difference between the above table and packing list, the packing list shall prevail. Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 15 Take the pipe clip off before connecting the pipes and wiring. Fit it when these finished. Use accessories 4 and 9 to connect the pipes /wires on both sides and back side. Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 16 Be sure the electric insulation work is well done if installed on metal ceiling /wall. e. Fix the unit feet with bolts (M10/M8). Be sure the unit is fixed strongly enough to against blast or earthquake. Make a concrete basement to the unit by the above references. Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 17: Refrigerant Pipe

    Gas leak check. Make sure no gas from connections with leak detector or soap water. Caution A: Lo packed valve B: Hi packed valve C and D are ends of indoor unit connection. Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 18 Screw the nuts tightly on the maintenance gap after the air has been drained. 3. To make the refrigerant pipe unblocked completely. Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 19: Filling Refrigerant

    After the evacuation is complete, fully close the handle Lo of the manifold valve and stop the operation of the vacuum pump. Make evacuation for 15 minutes or more and check that the compound meter Pa). indicates – 76cmHg (-10x10 Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 20: Drain Pipe

    Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. iii. To prevent the ingress of water, form a loop of the connective cable as Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 21: Outdoor Unit

    Connect the grounded wire to both indoor and outdoor units. This table is just an on-site wire-connecting example. The length of the power wire and connecting-wire which connects the indoor unit to the outdoor unit. (The figure given below shows a suitable length). Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 22 3. Check if all the functions works well while testing the air conditioner. Especially check whether the drainage of indoor unit is smooth or not. 4. Press the manual switch button again till the operation indicator turns dark after finishing the test operation and the unit stops operation. Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 23: Exploded View And Part List

    -23 - & & Indoor Unit Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 24 Left fixed clip for evaporator Right fixed clip for evaporator Upper fixing board for evaporator Evaporator Bracket of protector Tube protection board Right fixing board for evaporator Left-hand board Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 25 -25 - Outdoor Unit Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 26 Mid clapboard Right-hand board Cover for electric wiring Digger Wiring board Terminal board Fan motor capacitor AC contactor Compressor capacitor Capacitor clamp Four-way valve assembly Condenser assembly Top cover Left-hand propping board Motor bracket Motor Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 27: Circuit Diagram

    -27 - Indoor Unit Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 28 -28 - Outdoor Unit Model No.: AC-FR30HA Version: 1.0 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...
  • Page 29: Troubleshooting

    -29 - https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html Model No.: AC-FR30HA Version: 1.0...
  • Page 30 https://splitsystema48.ru/instrukcii-po-ekspluatacii-kondicionerov.html...

Table of Contents