Summary of Contents for akira AC-S10CG

  • Page 1 http://splitoff.ru/tehn-doc.html...
  • Page 2 Model: AC-S10CG Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 3: Table Of Contents

    Outline & dimension of outdoor unit…………………………………………… 11 Exploded view of indoor unit ……………………………………………………12 Spare parts list of indoor unit……………………………………………………13 Exploded view of outdoor unit………………………………………………….. 14 Spare parts list of outdoor unit…………………………………………………. 15 Circuit Diagram …………………………………………………………………..16 PCB Function Manual……………………………………………………………17 Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 4: Technical Specification

    Defrosting method Auto defrost Noise(dB(A)) Dimension(mm)(width-height-depth) 720 x 430 x 260 Net weight(Kg) Refrigerant charge(kg) R22/0.60 Length (m) Liquid pipe 6(1/4”) Outer diameter Connecting Gas pipe 9.52 (3/8”) pipe Height(m) Max distance Length(m) Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 5: Performance Curve

    PERFORMANCE CURVE The change relation between low pressure, operation current and temp. Cooling operation condition: In testing, indoor and outdoor have same work condition. Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 6 Heating operation Indoor work condition: dry bulb temp.21 , wet bulb temp. 15.5 Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 7 Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 8 Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 9 Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 10: Outline & Dimension Of Indoor Unit

    OUTLINES AND DIMENSIONS OF INDOOR UNIT Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 11: Outline & Dimension Of Outdoor Unit

    OUTLINES AND DIMENSIONS OF OUTDOOR UNIT Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 12: Exploded View Of Indoor Unit

    EXPLODED VIEW OF INDOOR UNIT Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 13: Spare Parts List Of Indoor Unit

    Transformer 43110170 Electric Box 20102010 Cable Clamp 70482001 Terminal Board T4A3A7377 42010183 Wire Clip 70482401 LED Holder 20182005 LED Board 30046023 Room sensor 39000164 Tube sensor 39000160 Connecting Cable 40020411 Power Cord 40020267 Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 14: Exploded View Of Outdoor Unit

    EXPLODED VIEW OF OUTDOOR UNIT Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 15: Spare Parts List Of Outdoor Unit

    Capillary assy 03003106 03003194 One way valve Reverse valve Clapboard assy 01233100 01233100 Compressor 00100031 Compressor 00120110 Valve 1/4" 07100125 07100125 Valve 3/8" 07100143 07100143 Valve support 01713036 01713036 Metal base 01203062 01203070 Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 17: Pcb Function Manual

    If it’s plugged in first time, the compressor does not have 3 minutes delay. When compressor is started, it will not stop within 5 min- utes unless it is plugged out. Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 18 T eva > or = 40 C or compres- sor have run 2 minutes ,indoor motor and swing motor will run at the set speed. Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 19 If T set + 2 < T indoor < T set + 4 C, keeps the original state. Cooling only AUTO mode: there is no heating function in this mode. Protections a. It is same as the one in cooling or heating mode. Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 20 2 === fresh air motor will work 1 hour, then rest 1 hour, then cycle again. fresh air 1 === press the button AIR on the remote controller to select fresh air 1 function, the swing motor keeps running till you give a signal to change it. Model No: AC-S10CG Version 1.0 : http://splitoff.ru/tehn-doc.html...
  • Page 21 C automatically, another 1 hour, another 1 will be added. b. In heating mode, 1 hour after you preset the sleep timer, T set will lower 1 C auto- matically, another 1 hour, another 1 C will be lowered. http://splitoff.ru/tehn-doc.html Model No: AC-S10CG Version 1.0...