DC Power Supply Modules ......................2-5 Power Supply Module Installation ....................2-6 Power Supply Module Replacement ....................2-6 Power Supply Fuse Replacement for the TRC-2190-AC ..............2-7 TRC-2190 Rack mounting ........................2-7 Installing the TRC-2190 Chassis ....................2-7 TRC-2190 Grounding ........................... 2-8 Initial IP Address Configuration ......................
Ethernet-to-fiber management modules. It also supports SNMP/web console for remote management and monitoring. TRC-2190 chassis comes with one AC or DC power input, with an optional redundant power expansion module available for greater reliability. The TRC-2190 Series’ power input module supports a fanless chassis design, as well as a -20 to 55°C operating temperature range.
The TRC-2190 Series is equipped with an AC or DC power supply installed in the back of the chassis. An extra installation space is available for an optional redundant power supply (AC or DC).
TRC-2190 Introduction Product Specifications Physical Characteristics Housing: SECC (1.2 mm) Dimensions: 440 x 260 x 88 mm (17.32 x 10.24 x 3.46 in) Weight: 5.2 kg (11.4 lb), with one power module installed Number of Slots: 18 slots on the front for slide-in modules, 2 slots at the back for power supply modules Environmental Limits Operating Temperature: -20 to 55°C (-4 to 131°F)
Getting Started This chapter covers the hardware installation of the TRC-2190. The following topics are covered in this chapter: Slide-in Module Installing or Removing Chassis Faceplate Installing the Media Converter Slide-in Modules Replacing the Media Converter Slide-in Modules ...
Secure the faceplate with the enclosed screw. ATTENTION Each slot in a TRC-2190 chassis without a slide-in module installed MUST have a chassis faceplate covering the empty slot for Class A compliance. Remove the front plate by loosening the screw before installing any slide-in modules. We suggest storing the...
5. Push in and rotate the attached panel-fastener screw clockwise to secure the module to the chassis. The TRC-2190-AC chassis is equipped with an AC power supply in the back of the chassis. When the power supply module is correctly installed in the back of the chassis, powering on the power supply module will power on the whole TRC-2190-AC.
An extra space is available at the right side of the back of the chassis to install an optional power module, the PWR-2190-AC. The specification is the same as the one that comes with the TRC-2190-AC chassis. Powering the AC Power Supply Module ATTENTION Ensure that the ON/OFF switch is set to “O”...
DC Power Supply Modules The TRC-2190-DC-48 is equipped with a DC power supply in the back of the chassis. When the power supply module is correctly installed in the back of the chassis, powering on the power supply module will power on the whole TRC-2190-DC-48.
TRC-2190 Getting Started Power Supply Module Installation ATTENTION Do not connect the power supply module to the external power source before installing it into the chassis. Failure to observe this may cause equipment damage, personal injury, or even death. 1. Install the AC power supply module and DC power supply module the same way. The default power supply module will be at power module Slot A.
(e.g., use of power strips) should be employed. The TRC-2190 series chassis is designed so that the installation brackets can be installed to align the chassis either flush against the front of the rack or recessed from the front of the rack.
TRC-2190 Getting Started To install the TRC-2190 chassis into a standard 19-inch rack: 1. Determine the preferred alignment of the chassis in the rack. NOTE Installation bracket mounting screws are provided. Rackmount screws and clip nuts are NOT provided. 2. Locate four (4) installation bracket mounting screws (provided) for each chassis to be installed.
Initial IP Address Configuration When setting up the TRC-2190 for the first time, the first thing you should do is configure its IP address. This chapter introduces the different methods that can be used. Refer to Chapter 5, System Management Settings, for more details about network settings.
Telnet to access the TRC-2190, and its IP address will be reconfigured. ATTENTION In order to use the ARP setup method, both your computer and the TRC-2190 must be connected to the same LAN. Alternatively, you may use a crossover Ethernet cable to connect the TRC-2190 directly to your computer’s Ethernet card.
When you enter this command, a “Connect failed” message will appear, as shown below. 5. After the TRC-2190 reboots, its IP address will be assigned to the new address, and you can reconnect using Telnet to verify that the update was successful.
Page 19
TRC-2190 Initial IP Address Configuration 4. Press N or use the arrow keys to select Network and then press ENTER. 5. Press B or use the arrow keys to select Basic and then press ENTER. 6. Use the arrow keys to move the cursor to IP address. Use the DELETE, BACKSPACE, or SPACE keys to erase the current IP address;...
Page 20
9. Press A or use the arrow keys to select Save and then press ENTER. Press ENTER again to confirm the save command. 10. Press R or use the arrow keys to select Restart and then press ENTER. 11. Press S or use the arrow keys to select System; then press ENTER to restart the TRC-2190.
1. Turn off the power to the TRC-2190. Use a USB cable to connect the TRC-2190’s USB console port to your computer’s male USB port.
Page 22
Initial IP Address Configuration 6. If the TRC-2190 has been set up for password protection, you will be prompted to enter the password. After you have entered the password, or if password protection was not enabled, you will be prompted to select the terminal mode.
Configuration with the Web Console The web console is the most user-friendly method available to configure the TRC-2190. With a standard web browser, you have easy and intuitive access to all settings and options. In this chapter, we introduce the web console and go through the basic configuration options.
2. Select the Privacy tab. There are six levels of privacy settings: Block All Cookies, High, Medium High, Medium, Low, and Accept All Cookies. Users must select Medium High (as the image shows below) to access the TRC-2190 web console. ATTENTION If you are not using Internet Explorer, cookies are usually enabled through a web browser setting such as “allow cookies that are stored on your computer”...
Trusted Site Settings For Windows 2003 users, you may need to add the TRC-2190’s IP address to your browser’s list of trusted sites. 1. If you see the following window while attempting to view the web console, click on Add… to modify the list...
ATTENTION If you forget your password, the ONLY way to configure the TRC-2190 is by using the reset button to reset all settings and load the factory defaults. If you have disabled the reset button in your TRC-2190 configuration, you may still use it to load the factory defaults within the first 60 seconds that the TRC-2190 is powered on.
Submit button, your settings will not be retained. Changes will not take effect until they are saved and the TRC-2190 is restarted! You may complete this in one step by clicking on the Save/Restart option after you submit a change. If you need to make several changes before restarting, you may save your changes without restarting by selecting Save Configuration in the navigation panel.
To modify the real-time clock, click on Modify next to the Local time field. Once you submit the new time, the TRC-2190’s firmware will modify the GMT time according to your time zone and local time settings.
IPv4 Address (default=192.168.127.254): Enter the IP address that will be assigned to your TRC-2190. All ports on the TRC-2190 will share this IP address. An IP address is a number assigned to a network device (such as a computer) as a permanent address on the network. Computers use the IP address to identify and talk to each other over the network.
Page 30
The TRC-2190 will play the role of a DNS client, in the sense that it will actively query the DNS server for the IP address associated with a particular domain name. The following functions on the TRC-2190 web console...
IPv6 Address (default= Auto): Enter the IPv6 address that will be assigned to your TRC-2190. All ports on the TRC-2190 will share this IPv6 address. An IPv6 address is a number assigned to a network device (such as a computer) as a permanent address on the network. Computers use the IPv6 address to identify and talk to each other over the network.
System Management Settings In this chapter, we describe additional server settings on the TRC-2190. The same configuration options are also available through the Telnet and serial console. The following topics are covered in this chapter: Misc. Network Settings SNMP Agent Settings ...
Contact name: The optional SNMP contact information usually includes an emergency contact name and telephone or pager number. Location: Use this optional field to specify the location string for SNMP agents such as the TRC-2190. This string is usually set to the street address where the TRC-2190 is physically located.
TRC-2190 System Management Settings Read-only and Read/write access control The following fields allow you to define user names, passwords, and authentication parameters for two levels of access: read-only and read/write. The name of the field will indicate which level of access it refers to. For...
System Management Settings System Log Settings System Log Settings allow the administrator to customize which network events are logged by the TRC-2190. Events are grouped into four categories, known as event groups, and the administrator selects which groups to log under Local Log. The actual system events that would be logged for each system group are listed under summary.
TRC-2190 System Management Settings Configure the Remote Log Server SYSLOG server Emergency IP address or domain name of remote log server. Alert Critical SYSLOG facility Error Syslog Facility is one information field associated with a syslog message. Warning SYSLOG severity Notice Order of severity, listed from the most to the least severe.
Password changed: With this option selected, the TRC-2190 will attempt to send an e-mail warning before it reboots with a new console password. If the TRC-2190 is unable to send an e-mail message to the mail server within 15 seconds, it will still reboot without sending the e-mail.
Trap version (default=v1): Use this field to select the SNMP trap version. Trap community (default=public_admin): Use this field to designate the SNMP trap community. Maintenance Console Setting On this screen, access to different TRC-2190 configuration console options (HTTP, HTTPS, Telnet, SSH) can be enabled or disabled.
System Management Settings Ping You can ping an IP address from the TRC-2190 web console in order to test the Ethernet connection. Enter the IP address or domain name in the Destination field to make sure that the connection is OK.
This function will reset all of TRC-2190’s settings to the factory default values. All previous settings, including the console password, will be lost. If you wish to keep the TRC-2190 IP address, netmask, and other IP settings, make sure Keep IP settings is checked off before loading the factory defaults.
To remove password protection, leave the New password and Confirm password boxes blank. ATTENTION If you forget the password, the ONLY way to configure the TRC-2190 is by using the reset button on the TRC-2190’s casing to load the factory defaults.
TRC-2190 System Management Settings System Monitoring Network Connections Go to Network Connections under System Status to view network connection information. Network Statistics Go to Network Statistics under System Status to view network statistics. Ethernet statistics Received: Total number of input datagram packets received from the Ethernet.
TRC-2190 System Management Settings ICMP statistics Received: Received packets of ICMP messages. REchoReq: Received packets from remote Ping request. REchoRply: Responding packets to remote Ping request. UDP statistics Received: Received UDP datagram packets. ErrHeader: Received UDP datagram packet with an incorrect header.
Restart Restart System Go to Restart System under Restart and then click Restart to restart the TRC-2190. Ensure that you save all your configuration changes before you restart the system or else these changes will be lost. 5-13...
Software Installation/Configuration Overview The Documentation & Software CD included with your TRC-2190 is designed to make the installation and configuration procedure easy and straightforward. This auto-run CD includes Windows Driver Manager (for COM mapping), Device Search Utility (to broadcast search for all TRC-2190’s accessible over the network), the TRC-2190 User’s Manual, and the TRC-2190 firmware upgrade utility.
Page 47
TRC-2190 Software Installation/Configuration 4. Click Next to install the program’s shortcuts in the appropriate Start Menu folder. 5. Click Next to proceed with the installation. The installer then displays a summary of the installation options. 6. Click Install to begin the installation. The setup window will report the progress of the installation. To change the installation settings, click Back and navigate to the previous screen.
Software Installation/Configuration Configuring Device Search Utility The Broadcast Search function is used to locate all TRC-2190 servers that are connected to the same LAN as your computer. After locating a TRC-2190, you will be able to change its IP address.
TRC-2190 Port Numbers In this chapter, which is included for your reference, we provide a list of TRC-2190 port numbers that may cause network problems if you set the TRC-2190 to one of these ports. Process Name Option Type Port Number...
The TRC-2190 has built-in SNMP (Simple Network Management Protocol) agent software that supports SNMP Trap, RFC1317 and RFC 1213 MIB-II. RFC1213 MIB-II Supported SNMP Variables The following table lists the standard MIB-II groups as well as the variable implementation for the TRC-2190. System MIB Interfaces MIB...
Need help?
Do you have a question about the TRC-2190 and is the answer not in the manual?
Questions and answers